  1. Low-Cost Chromatic Confocal Endomicroscope for the Diagnosis of Cervical Precancer

    … design and development of a chromatic confocal endomicroscope (CCE) that can examine the cervical tissue in vivo with a goal of aiding the diagnosis of cervical malignancy. The novelty of this device is to use longitudinal chromatic aberration to acquire cross-sectional images of the tissue …

    arizona-thes Repository record for Low-Cost Chromatic Confocal Endomicroscope for the Diagnosis of Cervical Precancer (opens in a new tab)

  2. Multimodal Foveated Endomicroscope for the Early Detection of Oral and Esophageal Cancer

    … with the goal of creating a multimodal endomicroscope that overcomes the limits of current diagnostic techniques for the early detection of oral and esophageal cancer with high sensitivity and specificity. The first stage in the development of the endomicroscope is the design, …

    rice Repository record for Multimodal Foveated Endomicroscope for the Early Detection of Oral and Esophageal Cancer (opens in a new tab)

  3. Développement d’un endomicroscope multiphotonique à deux couleurs pour l’imagerie du métabolisme énergétique cellulaire

    La microscopie multiphotonique est une modalité d’imagerie de pointe offrant des opportunités d’avancées remarquables en biologie mais aussi dans le domaine médical. Afin d’en exploiter pleinement le formidable potentiel au cœur même de la pratique clinique, le développement de nombreuses sondes …

    star-france Repository record for Développement d’un endomicroscope multiphotonique à deux couleurs pour l’imagerie du métabolisme énergétique cellulaire (opens in a new tab)

  4. A multimodal two-photon fluorescence endomicroscope and its associated tissue database to discriminate brain tumors intraoperatively

    … actuellement a été proposé. Cet outil, un endomicroscope multimodal fibré, fournira une information de diagnostic précise et instantanée sur les tissus sans excision, en per opératoire, et sera une vraie assistance pour le neurochirurgien pendant l’exérèse tumorale. Le développement de cet …

    star-france Repository record for A multimodal two-photon fluorescence endomicroscope and its associated tissue database to discriminate brain tumors intraoperatively (opens in a new tab)

  5. Design of a Fiber-Bundle Based Multispectral Confocal Endomicroscope for Tissue Visualization During Lung Biopsy Procedures

    … a multispectral fluorescence line-scan confocal endomicroscope was developed that employs a fiber bundle probe to image tissue at the distal tip of the biopsy introducer needle. For all fiber bundle probe-based fluorescence systems, the axial resolution is challenging to measure, mainly due to …

    arizona-thes Repository record for Design of a Fiber-Bundle Based Multispectral Confocal Endomicroscope for Tissue Visualization During Lung Biopsy Procedures (opens in a new tab)

  6. Développement d'un endomicroscope multiphotonique compact et flexible pour l'imagerie in vivo haute résolution de tissus biologiques non marqués

    … Ce manuscrit porte sur le développement d’un endomicroscope multiphotonique présentant des performances inédites. Ce dispositif est alimenté par un oscillateur titane-saphir standard. Vient ensuite un module de pré-compensation des distorsions linéaires et non linéaires se produisant dans la …

    star-france Repository record for Développement d'un endomicroscope multiphotonique compact et flexible pour l'imagerie in vivo haute résolution de tissus biologiques non marqués (opens in a new tab)

  7. Towards the development of an all-optical, non-contact, photon absorption remote sensing (PARS) endomicroscope for blood vasculature imaging

    … Photon Absorption Remote Sensing (PARS) endomicroscope for in vivo vascular imaging. The proposed system is designed to leverage the endogenous optical absorption of hemoglobin to achieve high-resolution contrast, without the use of exogenous labels or acoustic coupling, addressing …

    waterloo Repository record for Towards the development of an all-optical, non-contact, photon absorption remote sensing (PARS) endomicroscope for blood vasculature imaging (opens in a new tab)

  8. Conception et réalisation d’un endomicroscope polarimétrique de Mueller à fibre en vue d’une application à l’aide au diagnostic médical in vivo

    … ont pour objectif de concevoir et de réaliser un endomicroscope polarimétrique de Mueller à fibre, fondé sur la méthode bichromatique,répondant aux exigences de l’imagerie endoscopique in vivo. En premier lieu, nous mettons au point une procédure accélérée d’acquisition des données permettant de …

    star-france Repository record for Conception et réalisation d’un endomicroscope polarimétrique de Mueller à fibre en vue d’une application à l’aide au diagnostic médical in vivo (opens in a new tab)

  9. Computational Optical Sectioning in Fibre Bundle Endomicroscopy

    … (SIM) endomicroscopy. Lower-cost, simplified endomicroscopes have been developed which use widefield incoherent illumination. Optical sectioning can be introduced to these systems using SIM. SIM improves imaging using spatial modulation of the focal plane and capturing a three-frame sequence. …

    kent Repository record for Computational Optical Sectioning in Fibre Bundle Endomicroscopy (opens in a new tab)

  10. Concept de robot à tube concentrique magnétique : introduction et analyse : application aux interventions minimalement invasives

    … pour le Démonstrateur 4 du Labex ACTION (endomicroscope OCT actif). Les objectifs de cette thèse sont multiples : - proposition de solutions technologiques novatrices; - navigation vers la muqueuse olfactive, sans contact avec les parois nasales - développement d'une interface …

    star-france Repository record for Concept de robot à tube concentrique magnétique : introduction et analyse : application aux interventions minimalement invasives (opens in a new tab)

  11. Fiber-optic two-photon endomicroscopy: technology and applications

    … two-photon microscope into a fiber-optic endomicroscope poses tremendous physics and engineering challenges. Especially, the small collection aperture makes it inherently challenging to collect enough two-photon signal photons from unstained biological tissues in vivo. Proposed in this …

    jhu Repository record for Fiber-optic two-photon endomicroscopy: technology and applications (opens in a new tab)

  12. Multi-Modal Imaging Techniques for Early Cancer Diagnostics

    … imaging applications, new high resolution endomicroscope techniques are presented with improved lateral resolution, larger field-of-view, increased contrast, decreased background signal, and reduced cost compared to existing devices. A new widefield optical technology called multi-modal …

    rice Repository record for Multi-Modal Imaging Techniques for Early Cancer Diagnostics (opens in a new tab)

  13. New implementations of phase-contrast imaging

    … results of a computational fluorescence endomicroscope is also included. It uses a numerical method to achieve sectioning effect and renders a pseudo-3D image stack with a single shot. The results are compared with true-3D image stack acquired with a confocal microscope.

    bu Repository record for New implementations of phase-contrast imaging (opens in a new tab)

  14. Towards an early detection and mechanistic understanding of articular surface degeneration in osteoarthritis

    … a clinically approved probe-based confocal laser-endomicroscope. Here, such an endomicroscope could already be used on AC ex vivo to visualize the superficial chondrocyte spatial organization (SCSO), an image-based biomarker for the earliest structural changes in AC during OA.<br>An early OA …

    freiburg-diss Repository record for Towards an early detection and mechanistic understanding of articular surface degeneration in osteoarthritis (opens in a new tab)

  15. Micro-system based multimodality biomedical imaging and sensing system

    … be easily used for insertable, implantable and endomicroscope systems. With the emergence of the metalens and microoptoelectromechanical system (MOEMS), the current biomedical and sensing systems can be integrated into a compact size for disease early detection, image-guided surgery and therapy …