Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 87 for “"Energy calibration"”

  1. Energy Calibration in the DEAP-3600 Dark Matter Detector

    … a leading dark matter candidate. A new corrected energy variable has been developed using a three year data set. This calibration corrects for the number of working photomultiplier tubes and time drift with a mean uncertainty of 3.4 × 10^(−4) %. The uncertainty of the energy due to position …

    carleton Repository record for Energy Calibration in the DEAP-3600 Dark Matter Detector (opens in a new tab)

  2. THE LUX DARK MATTER EXPERIMENT: DETECTOR PERFORMANCE AND ENERGY CALIBRATION

    … in a stable platform for WIMP searching. The LUX energy reconstruction is then examined, followed by a breakdown of signal fluctuations as a function of energy as part of our understanding of back- ground discrimination in this class of detectors. Finally, I review the first LUX WIMP search …

    ohiolink Repository record for THE LUX DARK MATTER EXPERIMENT: DETECTOR PERFORMANCE AND ENERGY CALIBRATION (opens in a new tab)

  3. Energy calibration of the Sudbury neutrino observatory using monoenergetic gamma-ray sources

    … of neutrinos originating from the Sun. A high energy gamma-ray source is needed to calibrate SNO beyond the ⁸B solar neutrino endpoint of 15 MeV. This source must have a gamma-ray yield of > 0.2 s⁻¹ , a neutron yield of < 10⁴ s⁻¹ , and an operational lifetime of > 60 hours. To be compatible …

    ubc Repository record for Energy calibration of the Sudbury neutrino observatory using monoenergetic gamma-ray sources (opens in a new tab)

  4. Development of Low-Energy Calibration Techniques for SuperCDMS using LEDs Operated at Cryogenic Temperatures

    … To accomplish this, detectors have to have energy thresholds of a few eV. The Cryogenic Underground TEst facility (CUTE) is currently the underground facility equipped to operate the future SuperCDMS detectors. Since summer 2019, the facility has operated a variety of detectors to identify, …

    queens Repository record for Development of Low-Energy Calibration Techniques for SuperCDMS using LEDs Operated at Cryogenic Temperatures (opens in a new tab)

  5. Implementation of crystal mapping and energy calibration procedures for PET block detectors with pixelated scintillators

    … per-scintillating-crystal-array-element energy calibration of the annihilation gamma ray energy spectra collected by the block detectors, a necessary step as light collection efficiencies from elements of scintillating crystal array in a PET block detector are non-uniform and highly …

    regina Repository record for Implementation of crystal mapping and energy calibration procedures for PET block detectors with pixelated scintillators (opens in a new tab)

  6. DAQ Software Contributions, Absolute Scale Energy Calibration and Background Evaluation for the NOvA Experiment at Fermilab

    … software, providing an accurate, absolute-scale energy calibration for electromagnetic showers in NOvA detector elements, crucial to the primary electron neutrino search, and through an initial evaluation of the cosmic background rate in the NOvA Far Detector, which is situated on the surface …

    utk-theses Repository record for DAQ Software Contributions, Absolute Scale Energy Calibration and Background Evaluation for the NOvA Experiment at Fermilab (opens in a new tab)

  7. ENERGY CALIBRATION AND OBSERVATION OF THE HIGGS BOSON IN THE DIPHOTON DECAY WITH THE ATLAS EXPERIMENT

    … in the diphoton channel and the Monte Carlo calibration of electrons and photons. The Higgs boson is a particle predicted by the Standard Model to explain the mechanism for electroweak symmetry breaking, giving masses to the particles. A particle compatible with the SM Higgs boson has been …

    milano Repository record for ENERGY CALIBRATION AND OBSERVATION OF THE HIGGS BOSON IN THE DIPHOTON DECAY WITH THE ATLAS EXPERIMENT (opens in a new tab)

  8. The energy calibration for the solar neutrino analysis of all three phases of the Sudbury Neutrino Observatory

    This work presents the calibration of the energy response of the Sudbury Neutrino Observatory (SNO). The development of the energy response processor RSP and its use in setting the energy scale of SNO and reconstructing the energy of neutrino-like events is presented for each of the three phases of …

    queens Repository record for The energy calibration for the solar neutrino analysis of all three phases of the Sudbury Neutrino Observatory (opens in a new tab)

  9. Search for sterile neutrino oscillations with the SoLid experiment at BR2 reactor : Energy calibration of the detector and antineutrino signal extraction

    … sont ensuite présentés. Le premier étant la calibration en énergie du détecteur. Cette calibration représente une grande partie du travail décrit dans ce document. Celle-ci comprend la mesure de la quantité de lumière de chacune des cellules en plus de la linéarité et de l’homogénéité de la …

    star-france Repository record for Search for sterile neutrino oscillations with the SoLid experiment at BR2 reactor : Energy calibration of the detector and antineutrino signal extraction (opens in a new tab)

  10. I. Absolute measurement of a set of energy calibration standards. II. A study of the density of states in beryllium-8

    … been performed in an effort to obtain a set of energy standards which could be employed in calibrating analyzing magnets associated with various experimental nuclear physics problems. The second part of the thesis describes a study of the decay scheme for three-body nuclear decay. A recent paper …

    rice Repository record for I. Absolute measurement of a set of energy calibration standards. II. A study of the density of states in beryllium-8 (opens in a new tab)

  11. Energy calibration of the ATLAS electromagnetic calorimeter and search for Higgs Boson pair production in the bbyy final state with Run 2 and Run 3 data collected by the ATLAS detector

    Dix ans après la découverte du boson de Higgs, le LHC continue à raffiner les mesures de ses propriétés. La détermination de l'auto-couplage de Higgs pourrait indiquer la direction de la nouvelle physique et révéler l'histoire de l'univers primitif. Cette thèse présente la détermination de …

    star-france Repository record for Energy calibration of the ATLAS electromagnetic calorimeter and search for Higgs Boson pair production in the bbyy final state with Run 2 and Run 3 data collected by the ATLAS detector (opens in a new tab)

  12. ⁷Li(d,p)⁸Li excitation function :|bE[subscript d] = 0.623 MeV to 1.968 MeV

    … target (LiF) thickness. The uncertainty in the energy values was determined from an energy calibration of the accelerator used in this study. Resonances from the ^71i(p,n)^7Be (1.882MeV), 7Li(d,p)^8Li (0.770MeV; 1.02MeV) and ^19F(p,αγ)^16 0 reactions were used in this energy calibration.

    byu Repository record for ⁷Li(d,p)⁸Li excitation function :|bE[subscript d] = 0.623 MeV to 1.968 MeV (opens in a new tab)

  13. Analysis and Calibration of the MER-A APXS Alpha Particle Backscatter Spectra

    … by Monte Carlo simulations, provided an energy calibration to mitigate the absence of an alpha-mode calibration pre-flight. Data from a pre-flight thermal acceptance test agreed with this energy calibration, confirming the presence of an unexpected offset. Correcting a bug in the APXS …

    guelph Repository record for Analysis and Calibration of the MER-A APXS Alpha Particle Backscatter Spectra (opens in a new tab)

  14. Cherenkov detectors for transmission studies of monoenergetic high-energy photons in active interrogation applications

    … Cherenkov detectors reduce undesired low energy background, both natural and scatter from the application environment, while producing the capability of high contrast transmission imaging. Spectral analysis of the image can be used to confirm the presence of high-Z materials by analyzing …

    gatech Repository record for Cherenkov detectors for transmission studies of monoenergetic high-energy photons in active interrogation applications (opens in a new tab)

  15. Calibration of the Liquid Argon Calorimeter and Search for Stopped Long-Lived Particles

    … three main aspects of today's experimental high energy physics: detector operation and data preparation, reconstruction and identification of physics objects, and physics analysis.The symbiosis of these is the key to reach a better understanding of the underlying principles of nature. Data from …

    qucosa-diss Repository record for Calibration of the Liquid Argon Calorimeter and Search for Stopped Long-Lived Particles (opens in a new tab)

  16. Direct quantitative gross aB-measurements of environmental water contaminated with nuclides from the uranium, thorium and actinium decay series and semi-qualitative identification of nuclides concerned.

    … determination of the peak position or end-point energy. This requires energy calibration under various quenching conditions. The a-energy calibration is a correlation of a-energy and the channel peak position of the spectrum. The appearance of quenching in the sample affects not only counting …

    nwu-za Repository record for Direct quantitative gross aB-measurements of environmental water contaminated with nuclides from the uranium, thorium and actinium decay series and semi-qualitative identification of nuclides concerned. (opens in a new tab)

Page 1 of 5