Contaminant Transfer in a Run-Around Membrane Energy Exchanger
… Air-conditioning (HVAC) system when air-to-air energy recovery devices are used. The run-around membrane energy exchanger (RAMEE) is a novel exchanger, which uses aqueous magnesium chloride (MgCl2) salt solution (34-35 wt%) as a liquid desiccant to transfer heat and moisture between remote …
-
Run-around membrane energy exchanger performance and operational control strategies
A run-around membrane energy exchanger (RAMEE) is a novel energy exchanger that is capable of transferring both heat and moisture, which can significantly reduce the energy required to condition outdoor ventilation air. The RAMEE uses a liquid desiccant to transfer both heat and moisture between …
-
Building energy simulation of a Run-Around Membrane Energy Exchanger (RAMEE)
… impact of utilizing a novel Run-Around Membrane Energy Exchanger (RAMEE) in building HVAC systems. The RAMEE is an energy recovery ventilator that transfers heat and moisture between the exhaust air and the fresh outdoor ventilation air to reduce the energy required to condition the ventilation …
-
Run-Around Membrane Energy Exchanger Prototype 4 Design and Laboratory Testing
The run-around membrane energy exchanger (RAMEE) is a novel design that utilizes a membrane and a liquid desiccant to transfer heat and moisture between remotely located ducts. A laminate membrane called AY Tech ePTFE (expanded polyetrafluoroethylene) was sourced based on the vapour diffusion …
-
Selection of the liquid desiccant in a run-around membrane energy exchanger
… fluid to be used in a run-around membrane energy exchanger (RAMEE). The liquid desiccant is one of the main components of the RAMEE and indirectly conditions the outdoor ventilation air by using the energy of the exhaust air, significantly reducing the building energy consumption. Numerical …
-
Transient and Steady-state Performance of A Liquid-to-Air Membrane Energy Exchanger (LAMEE)
… of a counter-cross flow liquid-to-air membrane energy exchanger (LAMEE). The LAMEE is constructed from several semi-permeable membranes which separate the air and liquid streams. In addition to heat transfer, moisture transfer occurs between the air and liquid streams since the membranes are …
-
Design and performance testing of counter-cross-flow run-around membrane energy exchanger system
… a novel counter-cross-flow run-around membrane energy exchanger (RAMEE) system was designed and tested in the laboratory. The RAMEE system consists of two (2) counter-cross-flow Liquid-to-Air Membrane Energy Exchangers (LAMEEs) to be located in the supply and exhaust air streams in the building …
-
DESIGN AND PERFORMANCE TESTING OF A NOVEL 3-FLUID LIQUID-TO-AIR MEMBRANE ENERGY EXCHANGER
Liquid-to-air membrane energy exchangers (LAMEEs) allow simultaneous heat and moisture transfer between air and desiccant solution streams that are separated by semi-permeable membranes. Moisture transfer between the air and desiccant solution is accompanied by the release/absorption of phase …
-
Experimental detection and reversal of crystallization fouling in a liquid-to-air membrane energy exchanger
Liquid-to-air membrane energy exchangers (LAMEEs), which can simultaneously transfer heat and moisture between aqueous salt solutions and air, are designed to control the temperature and humidity in buildings. However, crystallization fouling may occur under some operating conditions where the salt …
-
APPLICATION OF NEURAL NETWORKS TO PREDICT THE PERFORMANCE OF A RUN-AROUND MEMBRANE ENERGY EXCHANGER (RAMEE)
… predict the performance of a Run-Around Membrane Energy Exchanger (RAMEE). The RAMEE is a novel air-to-air energy recovery system that is capable of transferring both heat and moisture between two air streams. The utilization of a properly controlled RAMEE in the HVAC system of a building can …
-
The impacts of outdoor air conditions and non-uniform exchanger channels on a run around membrane energy exchanger
… of the performance of a run-around membrane energy exchanger (RAMEE) at different outdoor air conditions and the effects of non-uniform exchanger channels. The RAMEE is a new type of building ventilation air energy recovery system that allows heat and moisture to be transferred between …
-
TESTING SMALL-SCALE AND FULL-SCALE LIQUID-TO-AIR MEMBRANE ENERGY EXCHANGERS (LAMEEs)
A liquid-to-air membrane energy exchanger (LAMEE) is a novel flat-plate membrane-based energy exchanger where heat and moisture transfer between air and solution streams occurs through a semi-permeable membrane. The LAMEE consists of many air and solution flow channels, each separated by a …
-
Condensation in membrane-based energy exchangers
Using energy exchangers in winter conditions, and hot and humid summer conditions can result in condensation. Condensation might affect the performance of the exchanger, facilitate the growth of micro-organisms and be a precursor to frost formation at lower temperatures. As a result, information …
-
Membrane deflection in energy exchangers
Experiments conducted on a commercial energy exchanger show that an applied pressure differential between the supply and exhaust flows leads to variations in the pressure drop along each flow path, which are caused by the membrane deflection. Membrane deflection in energy exchangers affects their …
-
FROSTING IN MEMBRANE ENERGY EXCHANGERS
Frost formation in heat/energy exchangers is undesirable because it may reduce air flow through the exchanger, increase the power consumption of fans, decrease the effectiveness of the exchanger, and in extreme cases, cause physical damage to the exchanger. Frosting is more critical in regions with …
-
Gaseous Contaminant Transfer in Membrane Energy Exchangers
Membrane-based air-to-air energy exchangers (M-AAEEs) reduce the energy required for conditioning building ventilation air by transferring heat and moisture between the building exhaust and ventilation air. However, M-AAEEs may also contaminate the ventilation air due to the transfer of …
-
Simulation of a 3-Fluid Membrane Liquid Desiccant Air-Conditioning System
A liquid-to-air membrane energy exchanger (LAMEE) is able to simultaneously cool and dehumidify air by transferring heat and moisture between the air stream and a liquid desiccant solution. The heat and moisture transfer rates in a LAMEE can be enhanced if a third fluid stream is used to control …
-
The effect of energy recovery on indoor climate, air quality and energy consumption using computer simulations
… thesis are to determine if the addition of an energy wheel in an HVAC system can improve the indoor air relative humidity (RH), and perceived air quality (PAQ), as well as reduce energy consumption. An energy wheel is an air-to-air energy exchanger that transfers heat and moisture between the …
-
A novel transient testing method for heat/energy wheel components
Heat wheels and energy wheels are widely used in ventilation systems to recovery sensible and latent energy, and consequently, reduce the energy required to condition outdoor ventilation air for buildings. This Ph.D. thesis proposes a novel transient testing facility and method to predict the …
-
Experimental study of air-to-air heat/energy exchangers for use in Arctic housing
ABSTRACT Experimental study of air-to-air heat/energy exchangers for use in Arctic housing Colin J. Beattie The thesis presents the experimental results of an air-to-air heat/energy exchanger (HEE), tested with four different cores, to assess the performance under Arctic climate conditions. Four …