Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 9 of 9 for “"Energyplus model"”.
-
Inverse modeling to predict effective leakage area
… the effective leakage area using the inverse modeling process as an alternative to the blower door test. An actual office building, which is the head quarter of Energy Efficiency Hub, was used as an example case in this study. The main principle of the inverse modeling process is comparing the …
-
Evaluation of Phase Change Materials for Cooling in a Super-Insulated Passive House
… data and through additional simulation using an EnergyPlus model validated with observed data. The study found that installation of the PCM had a positive effect on thermal comfort, reducing the estimated overheated hours from about 400 to 200.
-
Comparative Study of Thermal Comfort Models Using Remote-Location Data for Local Sample Campus Building as a Case Study for Scalable Energy Modeling at Urban Level Using Virtual Information Fabric Infrastructure (VIFI)
… located building can be utilized for energy modeling of a similar type of building and to demonstrate how to use this remote data without physically moving the data from one server to another using Virtual Information Fabric Infrastructure (VIFI). In order to achieve this goal, firstly an …
-
Building Energy Model Generation Using a Digital Photogrammetry-Based 3D Model
… and require skilled labor. As Building Energy Modeling (BEM) and simulations are becoming increasingly important, there is a growing need to make environmental assessments of buildings more efficient and accessible. A building energy model is based on collecting input data from the real, …
-
Modeling and Control of Passive Chilled Beams with Underfloor Air Distribution of Ventilation in Office Buildings in Humid Climates
… a humid climate and to develop a method for the modeling of passive chilled beams with a ventilation system and underfloor air distribution (UFAD). For the analysis, a 606,900 ft2 commercial office building in ASHRAE climate zone 3A with passive chilled beams and a ventilation system with UFAD …
-
Dynamic Building Envelope with Phase Change Material (PCM) and Multi-Layered Fenestration Using Model Predictive Controls
… Specifically, we have developed a Radiance model for daylighting performance estimation, and then this model was validated by carrying out a series of experiments under different conditions. The validation results showed that the Radiance modeling approach can generate reliable indoor …
-
Πειραματικές και υπολογιστικές μέθοδοι ενεργειακής αξιολόγησης κτιριακού κελύφους με έμφαση σε υπερ-μονωτικά υλικά
… of thermal bridges can be calculated by an EnergyPlus model by means of appropriate modifications of the material thermal properties.In this thesis, the numerical techniques are employed for the investigation of the energy and cost effectiveness of the VIPs for two theoretical real scale …
-
Field Validation of Zero Energy Lab Water-to-Water Ground Coupled Heat Pump Model
… the occupant. This study focuses on developing a model for the ground-source heat pump at the Zero Energy lab at the University of North Texas, and finding the minimum data required for generating the model. The literature includes many models with different approaches to determine the performance …
-
Uncertainty quantification of building energy model that assume ideal temperature control
… the room cooling and heating load. Commonly used EnergyPlus simulations introduce an idealization on the space temperature controllability by matching building zone partition with the HVAC supply network topology and using thermal zone as the atomic control object. This thesis targets an …