  1. Characterization of the enhanced dynamic wedge

    The Enhanced Dynamic Wedge (EDW) is an intensity modulated radiation therapy technique found in certain linear accelerators used in radiation oncology. Invoking the EDW causes one collimating jaw to move across the field to produce a predefined wedged dose distribution. Measured dose profiles were …

    mcgill Repository record for Characterization of the enhanced dynamic wedge (opens in a new tab)

  2. A dosimetric analysis of the varian enhanced dynamic wedge for symmetric and asymmetric configurations

    … telle technique dynamique implique l'usage du Enhanced Dynamic Wedge (EDW), qui module la dose de rayonnement à travers un axe d'un champ rectangulaire via le mouvement d'une mâchoire de collimator sous le contrôle informatique. La majorité d'applications cliniques de cette technique emploie un …

    mcgill Repository record for A dosimetric analysis of the varian enhanced dynamic wedge for symmetric and asymmetric configurations (opens in a new tab)

  3. Quantitative Analysis of the Head Scatter and Jaw Transmission Correction Factor for Commissioning of Enhanced Dynamic Wedge Fields Using a MapCHECK 2 Diode Array

    … using a two dimensional diode array for Enhanced Dynamic Wedge (EDW) fields. While these measurements met clinical standards for treatment, they revealed room for improvement in the EDW model. The purpose of this study is to analyze the head scatter and jaw transmission effects of the …

    ohiolink Repository record for Quantitative Analysis of the Head Scatter and Jaw Transmission Correction Factor for Commissioning of Enhanced Dynamic Wedge Fields Using a MapCHECK 2 Diode Array (opens in a new tab)

  4. Construction of a Liquid Scintillation Detector for Relative Megavoltage Dosimetry

    … dose factors, tissue maximum ratios, physical wedge factors, enhanced dynamic wedge factors and modulation factors for a patientint intensity modulated radiotherapy (IMRT) plan. Tests show that the measured values obtained agree well with a Protea ion chamber.

    alberta Repository record for Construction of a Liquid Scintillation Detector for Relative Megavoltage Dosimetry (opens in a new tab)

  5. The effects of intrafraction motion on dose heterogeneity

    … techniques commonly used in the clinic: physical wedge compensators (PWs), enhanced dynamic wedges (EDWs), and step-and-shoot intensity modulated radiation therapy (ssIMRT). Some of the effects of intrafraction motion can be eliminated with Gating Therapy. In this study, we have also investigated …

    sask Repository record for The effects of intrafraction motion on dose heterogeneity (opens in a new tab)

  6. Evaluation of an amorphous silicon electronic portal imaging device for use in radiation therapy dosimetry

    … of EPID and film images acquired during enhanced dynamic wedge treatments indicated that the film profiles show an increased response of film compared to the EPID as the distance from the central axis increases. The EPIDS dose response curve was characterized by comparing ion chamber …

    ubc Repository record for Evaluation of an amorphous silicon electronic portal imaging device for use in radiation therapy dosimetry (opens in a new tab)

  7. 2D transit dosimetry using electronic portal imaging device

    … and heterogeneous slab phantoms using open, enhanced dynamic wedge (EDW) and intensity modulated radiation therapy (IMRT) fields. Results showed that the model could accurately detect deviation between delivered and planned doses. Further evaluation with an anthropomorphic pelvic phantom and …

    glasgow Repository record for 2D transit dosimetry using electronic portal imaging device (opens in a new tab)

  8. Transit dosimetry based on water equivalent path length measured with an amorphous silicon electronic portal imaging device

    … The method was extended to include conformal and enhanced dynamic wedge (EDW) fields. A method was devised for the automatic calculation of areas (to establish the appropriate scatter correction) from the EPID image that facilitated the calculation of EPL for any field, and hence exit dose. For …

    glasgow Repository record for Transit dosimetry based on water equivalent path length measured with an amorphous silicon electronic portal imaging device (opens in a new tab)