Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 19 of 19 for “"Enthalpy relaxation"”
-
Enthalpy relaxation processes near the glass transition temperature of poly (ethylene terephthalate)
… spectra showed significant changes in the relaxation occurring in the annealed samples. In addition, volumetric studies of the annealed glasses showed changes in specific volume. In differential scanning calorimetry studies the absorbed thermal energy in the transition interval of annealed …
-
Phenomenological Study of Enthalpy Relaxation and Physical Aging of Glucose, Fructose and Their Mixture
"Enthalpy relaxation of glucose, fructose and their mixtures was investigated using the Tool-Narayanaswamy-Monihan (TNM) and the Adam-Gibbs model parameters. The apparent activation energy was found to decrease as the fructose content increased. The value of parameter x increased with the fructose …
-
EFFECT OF SILANOL CONTENT ON THE PROPERTIES OF SILICONE–POLYURETHANE HYBRID FILMS
… effectively invariant across all compositions. Enthalpy relaxation, quantified from the non-reversing heat flow component of MDSC, exhibited a non-monotonic dependence on PDMS content, with enthalpy relaxation decreasing from 7.90 J/g in the neat polyurethane to a minimum of 5.18 J/g at 2.5 wt% …
-
Stability of amorphous pharmaceuticals: Calorimetric studies
… was the feasibility of using IMC to assess enthalpy relaxation of amorphous pharmaceutical materials. In the first study, relaxation profiles for amorphous indomethacin obtained by differential scanning calorimetry (DSC) and IMC were compared. The results showed that the two techniques …
-
Glass transition kinetics of amorphous polymers
… lower than Tf', presumably due to the breadth of relaxation on cooling. The Tool-Narayanaswamy-Moynihan (TNM) model is used to fit the experimental data in order to ascertain the origins of higher value of Tg compared to Tf'. The values of Tg and Tf' are used to examine the relationship between …
-
Structure and Relaxation in Germanium Selenide and Arsenic Selenide Glasses
… changes in their properties, due to structural relaxation, over the weeks and months subsequent to their fabrication. Thus, obtaining a more thorough understanding of structural relaxation and its relation to the structure, composition, and processing of these glasses is important in furthering …
-
The effects of sub-TG annealing on the properties of glassy polymers
… state was studied as it related to volume and enthalpy relaxation. The polymers included PEEK (ICI) and co(imide methyl methacrylate) copolymers (Rohm & Haas) containing various levels of methyl methacrylate co-monomer in the main backbone. The polymers were characterized by DSC, dynamic …
-
Melt Dynamics Correlated with Glass Topological Phases in dry Li- and Na- Borates
… identified as fragility windows. Earlier, the enthalpy of relaxation at the glass transition temperature Tg , ?Hnr(x) of corresponding glasses were reported by Vignarooban et al. They observed square well-like reversibility windows in the same 20=x=40% and 14=x=27% composition ranges for NBG …
-
Glass Forming Ability and Relaxation Behavior of Zr Based Metallic Glasses
… the properties of metallic glasses change due to relaxation need to be understood better. The glass forming ability (GFA) with variation in composition and inclusion of different alloying elements was studied by using thermal techniques to determine important GFA indicators for Zr-based bulk …
-
Physical Aging of Miscible Polymer Blends
… and in the thermodynamic state (volume and enthalpy) were assessed for two different miscible polymer blends as a function of both composition and aging temperature. This investigation considered the physical aging behavior of blends containing atactic polystyrene (a-PS) and …
-
Thermal Properties of Commonly Used Clear Aligner Systems As-Received and After Clinical Use
… polymer went through the glass transition phase. Enthalpy relaxation, recrystallization temperature, and melting point were also analyzed. Results: There was no statistical difference in glass transition temperature between as-received and after use Invisalign, ClearCorrect, or Simpli5 aligners …
-
Time Dependent Properties of Semicrystalline Poly(Arylene Ether Ether Ketone) (Peek) Above and Below the Glass Transition
… the DSC scan of PEEK (peak maximum, transition enthalpy etc.) were found to evolve with annealing time and temperature during the secondary crystallization process in a way similar to the kinetics of development of the enthalpy relaxation process in amorphous polymeric glasses. This study …
-
Modified poly(lactic acid) sheets manufactured by one-step reactive extrusion-calendering : thermal, rheological, mechanical and fracture behaviours
… branch point). In the Tg region, the rate of enthalpy relaxation was found to decrease with increasing the entanglement network density under controlled aging periods at 30 °C. For a given thermal history, PLA-REX yielded comparative mechanical properties as those of PLA samples under uniaxial …
-
Structural relaxation of binary food systems
This project advanced the study of structural relaxation into two binary food systems. It studied the effect of anti-plasticizer addition (i.e. addition of glucose syrup solid and addition of starch) on structural relaxation of sucrose based amorphous mixtures. It also studied the effect of …
-
Structural relaxations and crystallization in amorphous food model formulations
… phase transitions associated with structural relaxations and their coupling with properties of food materials is still a challenging and developing area of food materials science. Our laboratory has developed a new approach for the use of α-relaxation times (τ) and introduced a “Strength, S” …
-
Advanced electrospun fibres as wound dressings for bacterial infections
… thermograms showed all the fibres have a PVA enthalpy relaxation peak at 47 °C and a PVA melting endotherm at 229 °C. The X-ray diffraction (XRD) patterns indicated decreased crystallinity of PVA after electrospinning. No crystalline drug could be detected in the fibres by either XRD or DSC. …
-
Crossing the glass transition during volcanic eruptions
… the modeling of heat capacity curves using the enthalpy relaxation geospeedometry method, which follows the Tool-Narayanaswamy-Moynihan (TNM) method. Cooling rates range from 10-1 to ca. 10-7 K min-1 and are dispersed inconsistently throughout the flow deposit. For the first time, the effect of …
-
Production and characterisation of bioresorbable polymers and polymer-glass composites for application in cardiac stents
… displayed severe embrittlement resulting from enthalpy relaxation, or degradation-induced crystallisation. Phosphate glasses are attractive as a reinforcing phase in polymer-glass composites to improve the mechanical properties, however uncertainty remains over their dissolution mechanisms, …
-
Dynamics and thermal behaviour of films of oriented DNA fibres investigated using neutron scattering and calorimetry techniques
… un comportement typique d’un verre. Leur relaxation thermique a été étudiée par calorimétrie. La diffusion inélastique de neutrons et de rayons X (INS et IXS) avaient été utilisées antérieurement pour mesurer les phonons longitudinaux dans des fibres d’ADN, avec des désaccords entre les …