Showing 1 to 12 of 12 for “"Equal Area Criterion"”.

  1. REAL-TIME POWER SWING DETECTION USING EQUAL AREA CRITERION

    … relays. The technique is based on the well known equal area criterion in the time domain. The basis of the protection technique is described in the thesis. The results from computer simulations show that the technique is able to correctly identify swings that are likely to result in dynamic …

    sask Repository record for REAL-TIME POWER SWING DETECTION USING EQUAL AREA CRITERION (opens in a new tab)

  2. Algorithms for power system security analysis

    … transient energy function methods: Extended Equal Area Criterion method, Relative Unstable Equilibrium Point method, Potential Energy Boundary Surface method. Assumptions for these methods and their affect on the accuracy are given. Detailed theoretical analysis, algorithms, and sensitivity …

    manitoba Repository record for Algorithms for power system security analysis (opens in a new tab)

  3. Out-of-step Protection Using Energy Equilibrium Criterion in the Time Domain

    … An out-of-step algorithm is proposed based on equal area criterion in time domain. The equal area criterion in time domain is obtained by modifying the traditional equal area criterion in power angle domain. A single machine infinite bus system, a two machine infinite bus system and a three …

    sask Repository record for Out-of-step Protection Using Energy Equilibrium Criterion in the Time Domain (opens in a new tab)

  4. A Practical Method for Power Systems Transient Stability and Security

    … of step-by-step and direct methods using Equal Area Criterion. The proposed method is extended for transient stability analysis of multi machine power systems. The proposed method calculates the potential and kinetic energies for all machines in a power system and then compares the largest …

    uno Repository record for A Practical Method for Power Systems Transient Stability and Security (opens in a new tab)

  5. The electrical breakdown characteristics of oil/paper insulation under fast front impulse voltages

    … using the histogram, Weibull distribution and equal area criterion methods. A 2% probability V-t curve was generated and fits the data well. The V₅₀ test results showed that the fast front impulse waveform has the lowest breakdown voltage and the switching impulse has the highest breakdown …

    ubc Repository record for The electrical breakdown characteristics of oil/paper insulation under fast front impulse voltages (opens in a new tab) Download PDF for The electrical breakdown characteristics of oil/paper insulation under fast front impulse voltages (opens in a new tab)

  6. Adaptive out-of-step relaying with phasor measurement

    … made more secure by applying the principle of equal area criterion. The main contribution of this dissertation is the use and application of old and new adaptive concepts as well as new technology to the solution of the out-of-step problem for a system that behaves like a two machine system. …

    vt Repository record for Adaptive out-of-step relaying with phasor measurement (opens in a new tab)

  7. Adaptive out of step relay algorithm

    … for these two types of disturbances the extended equal area criterion(EEAC) is used to make an extremely quick and accurate prediction of the relative stability between them. For stable oscillations following a disturbance, circuit breakers at the 500 kV interconnections are blocked from tripping. …

    vt Repository record for Adaptive out of step relay algorithm (opens in a new tab)

  8. Real-time phasor measurements for improved monitoring and control of power system stability

    … conjunction with a. new version of the Extended Equal Area Criterion (EEAC) method. The latter is able to handle complex loads through the dynamic Ward equivalencing method. The performance of the approach is illustrated on three test systems which have been reduced to the internal generator …

    vt Repository record for Real-time phasor measurements for improved monitoring and control of power system stability (opens in a new tab)

  9. A fast method for out-of-step protection using state plane trajectories analysis

    … at the instant the fault is cleared should be equal to the maximum potential energy of the system. The critical clearing time corresponding to this value of critical clearing angle is obtained directly using the time calibration of the relative speed versus power angle solution curve. The …

    sask Repository record for A fast method for out-of-step protection using state plane trajectories analysis (opens in a new tab)

  10. MACHINE LEARNING-BASED FRAMEWORK FOR REMEDIAL CONTROL ACTION PREDICTION USING WIDE-AREA MEASUREMENTS IN INTERCONNECTED POWER SYSTEMS

    … implementation, practical aspects, and wide-area measurement systems (WAMS). In this study, the different parts of the framework are discussed in detail and implemented. Based on the above discussion, first, an optimized artificial neural network (ANN) is implemented to make a comprehensive …

    sask Repository record for MACHINE LEARNING-BASED FRAMEWORK FOR REMEDIAL CONTROL ACTION PREDICTION USING WIDE-AREA MEASUREMENTS IN INTERCONNECTED POWER SYSTEMS (opens in a new tab)

  11. Machine Learning-Incorporated Transient Stability Prediction and Preventive Dispatch for Power Systems with High Wind Power Penetration

    Historically, transient instability has been the most severe stability challenge for most systems. Transient stability prediction and preventive dispatch are two important measures against instability. The former measure refers to the rapid prediction of impending system stability issues in case of …

    sask Repository record for Machine Learning-Incorporated Transient Stability Prediction and Preventive Dispatch for Power Systems with High Wind Power Penetration (opens in a new tab)

  12. A Local Measurement Based Protection Methodology for Initiating Controlled Islanding in Power Systems

    … methods to solve this aspect are based on wide area measurement system (WAMS), which are either offline (Decision Tree) based that require time-consuming periodic offline simulation, or real-time based using a computationally intensive algorithm. The complexity in most of the real-time methods …

    sask Repository record for A Local Measurement Based Protection Methodology for Initiating Controlled Islanding in Power Systems (opens in a new tab)