Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 32 for “"Equilibrium cell"”

  1. Gas Sweetening; Determination of Equilibrium Distribution Coefficients for Hydrogen Sulfide, Carbon Dioxide and Methane in Methanol

    Equilibrium distribution coefficients for hydrogen sulfide, carbon dioxide and methane in methanol were determined for a pressure range of 100 psi - 1000 psi and room temperature. An equilibrium cell was used and vapor molar fractions were determined by gas chromatograph.

    okstate Repository record for Gas Sweetening; Determination of Equilibrium Distribution Coefficients for Hydrogen Sulfide, Carbon Dioxide and Methane in Methanol (opens in a new tab)

  2. High pressure phase equilibrium studies.

    … multipmpose high-pressure vapour-liquid equilibrium (HPVLE) apparatus of the static type. The equilibrium cell was approximately 200 cm3 in volume, and by use of a stepper motor and piston, was also variable in volume. The equipment had a combined pressure and temperature operating limit …

    ukzn Repository record for High pressure phase equilibrium studies. (opens in a new tab)

  3. DESIGN AND DEVELOPMENT OF GENERALIZED APPARATI TO STUDY THE PHASE AND VOLUMETRIC BEHAVIOR OF PURE COMPONENTS AND MIXTURES AT ADVANCED TEMPERATURES AND PRESSURES, AND ANALYTICAL EXAMINATION OF THE RESULTING OBSERVATIONS

    … high temperature-high pressure vapor-liquid-equilibrium (VLE), gas solubility, and pressure-volume-temperature (PVT) data for compounds and mixtures which are of interest in coal liquefaction processes. The heart of the apparatus was a novel variable volume equilibrium cell which consisted of …

    rice Repository record for DESIGN AND DEVELOPMENT OF GENERALIZED APPARATI TO STUDY THE PHASE AND VOLUMETRIC BEHAVIOR OF PURE COMPONENTS AND MIXTURES AT ADVANCED TEMPERATURES AND PRESSURES, AND ANALYTICAL EXAMINATION OF THE RESULTING OBSERVATIONS (opens in a new tab)

  4. Development of techniques for the supercritical fluid extraction of oils

    … analysis method have been developed to provide equilibrium data for supercritical fluid solvents CO₂, C₂H₄, C₂H₆, C₃H₆ and C₃H₈ in tne presence of a multicomponent separator oil. The equilibrium cell was developed around a 1 dm³ high pressure autoclave. The maximum pressure and temperature …

    ubc Repository record for Development of techniques for the supercritical fluid extraction of oils (opens in a new tab)

  5. Experimental investigation of the thermophysical properties affecting CO₂ enhanced oil recovery

    … were measured with a setup which consists of an equilibrium cell, cryostat, rocking/pivot mechanism, and temperature/pressure recording equipment controlled by a PC. The equilibrium cell is a piston-type variable volume (maximum effective volume of 300 ml), titanium cylindrical pressure vessel …

    heriot-watt Repository record for Experimental investigation of the thermophysical properties affecting CO₂ enhanced oil recovery (opens in a new tab)

  6. A vapour-liquid equilibrium study on sub-critical systems using a static apparatus.

    High pressure vapour-liquid equilibrium experiments were undertaken with a static high-pressure apparatus designed by Prof. J. D. Raal and commissioned by Prof. D. Ramjugernath. Isothermal VLE binary data data was measured at moderate temperatures and pressures ranging from atmospheric to 7.2 bar. …

    ukzn

  7. Model and theoretical simulation of solid oxide fuel cells

    <p>Solid oxide fuel cells have been investigated frequently with models predicated on linear electrical circuit elements, ignoring finer details of electrochemical transport. To gain better understanding of the operation of solid oxide fuel cells based on their underlying physics, the most simple …

    ohiolink Repository record for Model and theoretical simulation of solid oxide fuel cells (opens in a new tab)

  8. Caracterização de amostras de petróleo e modelagem termodinâmica

    … experiments were performed with the sample in an equilibrium cell in which it is possible to apply the visual method and the expansion chamber, under specific conditions of molar concentration (20 – 60 % of sample) and temperature (30 - 120 °C). The results obtained were compared with those …

    brazil-ufrn Repository record for Caracterização de amostras de petróleo e modelagem termodinâmica (opens in a new tab)

  9. Cellular osmotic properties and cellular responses to cooling

    … hypothesis of cryoinjury, depending on cellular osmotic properties, will describe outcomes of cryobiological experiments. In addition, this thesis demonstrated that knowledge gained from improved descriptions of cellular osmotic parameters allows better understanding of cryoinjury and …

    alberta Repository record for Cellular osmotic properties and cellular responses to cooling (opens in a new tab)

  10. The design of two apparati to measure solid-liquid and liquid-liquid equilibria data.

    … uses a cryogenic fluid in a thermostatted glass cell for cooling of the sample. The Peltier design is for small sample volumes, with a 10 cm3 aluminium equilibrium cell and has a minimum operating temperature of 253.15 K. The glass design is developed to complement the Peltier and has a larger …

    ukzn Repository record for The design of two apparati to measure solid-liquid and liquid-liquid equilibria data. (opens in a new tab)

  11. Chromium poisoning of cathode in solid oxide fuel cells: mechanisms and mitigation strategies

    Solid oxide fuel cells (SOFCs) have gained renewed interest due to their high energy-conversion efficiency, new discovery of fossil fuel sources, and low greenhouse gas emission. However, performance degradation during long-term operation is one of the greatest challenges to overcome for …

    bu Repository record for Chromium poisoning of cathode in solid oxide fuel cells: mechanisms and mitigation strategies (opens in a new tab)

  12. Dados de equilíbrio de fases a altas pressões para sistemas sintéticos e amostras de petróleo

    … systems of petroleum. A high pressure phase equilibrium cell, that allows a range of pressure between 6 and 30 MPa and temperatures up to 393 K, based on synthetic visual method, was used for the PVT study. This cell was also used for PVT data determination using the non-visual synthetic …

    brazil-ufrn Repository record for Dados de equilíbrio de fases a altas pressões para sistemas sintéticos e amostras de petróleo (opens in a new tab)

  13. Modification and commissioning of a static high pressure apparatus and phase equilibria measurements for fluorinated hydrocarbons.

    … to a static high pressure vapour-liquid equilibrium (VLE) apparatus described by Naidoo [2004]. The alterations were made to improve the sample analysis technique. These modifications included the incorporation of the ROLSITM sampling device into the equilibrium cell, a re-design of the …

    ukzn Repository record for Modification and commissioning of a static high pressure apparatus and phase equilibria measurements for fluorinated hydrocarbons. (opens in a new tab)

  14. Phase equilibrium studies at normal pressures

    … has been developed to measure vapour-liquid equilibrium data on binary mixtures at atmospheric and sub-atmospheric pressures. The method gives isothermal data which can be obtained rapidly. Only measurements of total pressure are made as a direct function of composition of synthetic liquid …

    aston Repository record for Phase equilibrium studies at normal pressures (opens in a new tab)

  15. Equilíbrio de fases e comportamento volumétrico de sistemas aquosos contendo CO2, monoetileno glicol e NaCl nas condições de explotação de gás natural

    … the evaluation of volumetric behavior and phase equilibrium in mixtures, under conditions of temperature and pressure, close to those of gas exploration in deep waters, evaluating parameters such as density and solubility, at pressures from 4,0 to 31.0 MPa and temperatures of 293.15 and 323.15 K. …

    brazil-ufrn Repository record for Equilíbrio de fases e comportamento volumétrico de sistemas aquosos contendo CO2, monoetileno glicol e NaCl nas condições de explotação de gás natural (opens in a new tab)

  16. Phase equilibria studies on chemical mixtures encountered in the natural gas industry.

    … processing of natural gas were studied. Phase equilibrium measurements were performed using a combined static (synthetic or analytic) apparatus. The apparatus comprises a horizontal cylindrical sapphire tube fitted with a movable piston that can be used to adjust the cell volume, thereby …

    ukzn Repository record for Phase equilibria studies on chemical mixtures encountered in the natural gas industry. (opens in a new tab)

  17. Analysis and performance of symmetric nonaqueous redox flow batteries

    … the same solution composition to operate at high cell voltages. This research effort targets these systems since they offer performance improvements derived from using nonaqueous systems and symmetric active species. Nonaqueous solutions permit significantly higher cell voltages than …

    oxford Repository record for Analysis and performance of symmetric nonaqueous redox flow batteries (opens in a new tab)

  18. Separation of noble gas mixtures of (Xe, Ar and Kr) using gas hydrate technology.

    … with the use of a 52 ml stainless steel equilibrium cell. Different gas mixtures with various compositions ranging from 19 to 70 mol% xenon were investigated. To check the reliability of both the experimental equipment and procedures used in this study, dissociation data for the simple …

    ukzn Repository record for Separation of noble gas mixtures of (Xe, Ar and Kr) using gas hydrate technology. (opens in a new tab)

  19. Obtaining Temperature Dependence of Cell Membrane Permeability Parameters Using Non-Ideal Thermodynamic Assumptions to Mathematically Model Real Cryopreservation Protocols

    … process of preserving biological matter such as cells, tissues, and organs, at sub-zero temperatures for long-term storage. Cells at low temperatures are susceptible to mechanical damage due to intracellular ice formation and osmotic injuries related to increasing concentration of solutes as the …

    alberta Repository record for Obtaining Temperature Dependence of Cell Membrane Permeability Parameters Using Non-Ideal Thermodynamic Assumptions to Mathematically Model Real Cryopreservation Protocols (opens in a new tab)

Page 1 of 2