Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 29 for “"Equivalent damping"”.
-
Simple equivalent linearization of yielding MDF structures subjected to random excitation
A simple equivalent linear multi-degree-of-freedom (MDF) model is proposed to approximate the stationary rms response levels of yielding MDF structures subjected to Guassian random base excitation. The linear model is characterized by an equivalent stiffness for each yielding element, and a damping …
-
A MULTI-MODE MAGNETORHEOLOGICAL AXIAL ISOLATOR
… that are finding success where controllable damping is required. The goal of this work is to determine a suitable design of a six-degree-of-freedom MR isolator for vibration attenuation of a sensor platform and characterize its axial performance through experiments as well as theoretical …
-
Συμβολή στις μεθόδους ανάλυσης για τον αντισεισμικό σχεδιασμό μικτών καθ' ύψος κατασκευών από σκυρόδεμα και χάλυβα
… the two parts, and (ii) the determination of the damping ratios in a coupled analysis. The study of the decoupling error is performed arithmetically and covers a range of dynamic characteristics of the two parts of the structure. The result is error curves that allow the prediction of the …
-
Probabilistic Seismic Demand Model and Fragility Estimates for Symmetric Rigid Blocks Subject to Rocking Motions
… on the estimation of approximate period and equivalent damping ratio for the rocking motion. Thereafter, instead of using an iterative solution, which was previously proven defective, a new approximate technique is developed by finding the best representative ground motion intensities. …
-
The Damping of Vibration With a Particle Impact Damper
… The first problem is to determine the damping characteristics of free oscillation from an initial displacement for a vertical system. The second one was the application of a particle impact damper under the forced vibrating condition. This damper should reduce the vibration amplitude …
-
Damping and stiffening forces of a squeeze-film between two plates
… of the squeeze film has been represented by the damping effect in previous studies. Our goal, however, is to quantify the stiffening effect, which affects the resonance frequency of the squeeze film and oscillator system. In this research, the finite difference method for rectangular geometries …
-
An overdamped multimodal adaptive nonlinear static procedure for seismic assessment of rc infilled frames
… In addition, the D-DAP is equipped with an equivalent damping to consider the increase of the energy dissipation due the cumulated damage in the structure. To this end, the value of the equivalent damping is updated at each step according to a new damping law that has been properly …
-
Analytical and experimental investigations of ships impact interaction with one-sided barrier
… The difference between localized and distributed equivalent damping approaches is discussed. Extensive numerical simulations are carried out for all initial conditions covered by the ship grazing orbit for different values of excitation amplitude and frequency of external wave roll moment. The …
-
A Study of Variable Friction Base Isolation Systems
… Greater energy dissipation results in higher damping and, in turn, in lower seismic demand on the system. More specifically, more dissipative base isolation systems offer better seismic protection in that they lower the overall displacement demand and limit the lateral forces and accelerations …
-
Active adaptive auxiliary circuit for stabilizing dc distribution systems with constant power loads
… that address this problem use passive or active damping to reshape the source/load impedances so that stability may be achieved. The drawbacks of most existing methods include energy losses in passive components and/or requirement of changing the internal controls in existing loads. This thesis …
-
Development of an Efficient Design Method for Non-synchronous Vibrations
… are determined. This mode is acceptable if the equivalent damping is greater than zero for all IBPAs. A method for blade re-design is also proposed to determine the maximum blade response by finding the limit cycle oscillation (LCO) amplitude. It is assumed that outside of the lock-in region is …
-
Numerical Simulations of a Wave Energy Conversion Device Used for Oceanographic Buoys
… estimated using an iterative scheme to estimate equivalent damping of a hydraulic Power Take-Off (PTO) system. Several illustrative case studies are presented to verify that the electrical power output rate is in the range of the power demands needed by typical oceanographic buoys. It is …
-
Dynamical Modelling of an Idealized Hemispherical Skull Model with Fluid Pressure Interactions Using Modal Analysis
… of the results reveals that the dynamic model’s equivalent damping and stiffness parameters are sensitive to fluid pressure variations while the equivalent mass parameter is relatively unaffected. As a result of this study we conclude that variance in CSF pressure has a measurable effect on the …
-
Path Following Control for Multiple Quadrotors Carrying A Rigid-body Slung Payload
… payload delivery. The MPC method utilizes the equivalent damping force from the previous controller as the baseline stabilizing inner loop. The linearized closed-loop model is then calculated. Finally, the optimum controller is calculated after a prediction horizon and a cost function are …
-
High Temperature Leakage Performance of a Hybrid Brush Seal Compared to a Standard Brush Seal and a Labyrinth Seal
… tests. A combined structural and dry friction damping model represent well the measured flexibility. An equivalent damping is found based upon the energy dissipation. Based upon the damping ratio, the HBS has twice of the viscous damping as the brush seal at a supply pressure of 2.0 bar.
-
Vibration Modeling and Analysis of a Single Conductor With Stockbridge Dampers
… load and the Stockbridge damper is reduced to an equivalent discrete mass-spring-mass and viscous damping coefficient. The second model is based on a double-beam concept. The main beam with an axial load is a representation of the conductor and the Stockbridge damper is modeled as an in-span beam …
-
Soil-Spring Model for Fatigue Evaluation of Cyclic-Loaded Offshore Conductors
… head. The test interpretation involved deducing equivalent soil resistance (P) and pile deflection (y) measurements from the strain gage data. The former is particularly challenging, because it requires obtaining numerical second derivatives from a spatial array of strain gages. For this purpose …
-
Modal Analysis of Composite Structures with Damping Material
… coordinate vector and the assumed mode. The equivalent damping ratio of the active control system is calculated as the ratio between the kinetic energy absorbed by the piezoelectric actuator from the system in one oscillation and the maximum strain energy of the system during that …
-
Semi-active damping control for vibration isolation of base disturbances
This thesis is concerned with semi-active damping control for vibration isolation of base disturbances. The aim is to investigate the effectiveness and suitability of semi-active damping control strategies for improving steady-state vibration isolation. A single-degree-of-freedom (SDOF) system, …
-
Development of Magnetorheological Fluid Elastomeric Dampers for Helicopter Stability Augmentation
… energy and provide stiffness, but their damping and stiffness levels diminish markedly as amplitude of damper motion increases. Magnetorheological (MR) fluids based dampers have controllable damping with little or no stiffness. In order to combine the advantages of both elastomeric …
Page 1 of 2