Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 32 for “"Error Sensor"”.
-
Error Sensor Placement for Active Control of an Axial Cooling Fan
… (ANC) for cooling fans have used near-field error sensors whose locations are determined according to a theoretical condition of minimized sound power. A theoretical point source model, based on the condition previously stated, reveals the location of near-field pressure nulls that may be …
-
Optimization of Control Source and Error Sensor Locations in Free Field Active Noise Control
… fans. Optimization of the control source and error sensor placement is desired to maximize the attenuation using ANC. A genetic algorithm was developed to find the optimal placement of control sources for a given primary source. The optimal configuration of control sources around a single …
-
Error Sensor Strategies for Active Noise Control and Active Acoustic Equalization in a Free Field
Several measurements may be used as error signals to determine how to appropriately control a sound field. These include pressure, particle velocity, energy density and intensity. In this thesis, numerical models are used to show which signals perform best in is free-field active noise control …
-
Active Control of Cylindrical Shells Using the Weighted Sum of Spatial Gradients (WSSG) Control Metric
… In most cases a considerable number of error sensors and secondary sources are needed. However, in practice it is much preferred to have the fewest number of error sensors and control forces possible. Most methods presented have shown considerable dependence on the error sensor location. …
-
Hybrid adaptive feedforward control of structures to seismic inputs
… system. 3. Peak. structural responses during sensor failures were observed to increase, in particular for the failure of the first error sensor. However, the peak. responses during these failures never reached the peak. values obtained by the system with passive control. This demonstrated the …
-
Active control of vibration in stiffened structures
… of control source(s) and the location of the error sensor(s) on the achievable attenuation and the control forces required for optimal control. Comparison is also made between the results for the cases with multiple control sources driven by the same signal and with multiple independently …
-
Investigation of combined feedback and adaptive control of cylinder vibrations
… condition Polyvinylidene Fluoride Filnl (PVDF) sensor outputs as strain rate signals. The strain rate signals are used in the feedback loop to provide damping to the structure. In conjunction with the feedback loop a feedforward loop is also implemented. The feedforward loop utilizes the …
-
Analytical investigation of active control of radiated inlet noise from turbofan engines
… configurations of secondary control sources and error sensors. Two error sensing strategies are considered in this work. The first approach uses microphones placed in the acoustic far field. The second sensing technique consists of placing distributed error sensors in the engine inlet. …
-
Active control of low frequency ‘buzz-saw’ tones radiated from an aircraft engine on take off
… sum of the square pressures at a single ring of error sensors using a single ring of control actuators. In the absence of noise and extraneous modes, the level of control performance is fundamentally limited by the level of the evanescent modes at the error sensor array. An analytic model is …
-
Design of Active Structure Acoustic Control Systems Using Eigenassignment Approach
… system has equal number of control inputs and error sensor outputs, the feedforward controller can effectively modify the system dynamics (i.e., resonance frequencies and mode shapes). This provides the theoretical basis for the eigenassignment method. For the non-volumetric design, the …
-
Active Minimization of Acoustic Energy Density in a Mock Tractor Cab
… sides and a Plexiglas® front. An energy density sensor, capable of measuring acoustic pressure as well as acoustic particle velocity, provided the error signal to the control system. The ANC system operated on a single reference signal, which, for experiments involving recorded tractor engine …
-
Attenuation of Turbulent Boundary Layer Induced Interior Noise Using Integrated Smart Foam Elements
… Smart Foam actuators each having a reference and error sensor along with a feed forward, filtered-x controller. Studies were performed to determine if the use of multiple instances of single input, single output (SISO) control systems could be implemented with success given the difficulty of …
-
Spatially fixed and moving virtual sensing methods for active noise control.
… systems generate a zone of quiet at the physical error sensor location. While significant attenuation is achieved at the error sensor, local noise control is not without its problems, chiefly that the zone of quiet is generally small and impractically sized. It may be inconvenient to place the …
-
Active control of automobile cabin noise with conventional and advanced speakers
… in order to optimize the positions of the error sensors and the control sources. Experimental work was performed with the optimized actuator and sensor locations in order to validate the model, and draw conclusions regarding the conditions to obtain global control of the sound field. …
-
Active Minimization of Acoustic Energy Density to Attenuate Radiated Noise from a Diesel Generator
… control, but this was limited to regions at the error sensor. An overall SPL reduction of 1.9 dBA outside the enclosure was achieved near the power terminal side of the enclosure. This was accomplished using tonal and broadband feedforward control. Experimental results show that control source …
-
Intelligent Fault Tolerant Control Schemes For Autonomous Underwater Vehicles
… in order to increase its fault tolerance to both sensor and actuator faults. Faults occurring within the sensors for both the yaw and roll channels of the AUV are considered. Novel fuzzy inference systems (FISs) are developed and tuned using both the adaptive neuro-fuzzy inference system (ANFIS) …
-
Sensitivity Analyses of Optimized Attitude Estimators Using Sensor Fusion Solutions for Low-Cost MEMS Configurations
… analyses the performance and sensitivity of four sensor fusion solutions for attitude estimation under multiple simulated flight conditions. There are three different hardware configurations between the four estimators. For this reason, each estimator is tuned to be experimentally optimal, as to …
-
Active Control of the Human Voice from a Sphere
… a sphere using a genetic algorithm. The optimal error sensor location was found from exploring the nulls associated with the magnitude of the radiated pressure with reference to the primary pressure field. Both numerically predicted and experimentally validated results for the attenuation of …
-
Optimum design for feedforward structural-acoustic control of complex structural systems
… where the optimum modal control forces and modal error sensor components which minimize the total radiated power are obtained. These optimum modal parameters are then used in a set of lower level optimization problems to find the physical characteristics of the actuators and sensors to be …
Page 1 of 2