Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 46 for “"Eurocode 3"”.
-
Optimum design of cold-formed steel purlins using genetic algorithms
… geometrical and strength constraints provided in Eurocode 3, Part 1.3, and fabrication constraints. The design of cold-formed steel purlins is based on Eurocode 3, Part 1.3. The integrated design method is general for any shape of cold-formed steel purlins. However, in this thesis, the …
-
Behaviour of unstiffened column webs in bolted beam-to-column connections in building frames
… endplates connections.<br/>Investigation of Eurocode 3-Annex J was also undertaken with emphasis on the 7 connections that failed by column web buckling. Comparison between the three different prediction methods were investigated, this involved comparing physical test, Eurocode 3 and finite …
-
Problematika spolehlivosti ocelových prutových prvků citlivých na imperfekce
… a vyhotoveno porovnání s přístupem popsaným v Eurocode 3.
-
Flange Buckling Behavior of Stainless Steel Girders with Trapezoidally Corrugated Webs - A parametric numerical study
… models for carbon steel girders suggested by Eurocode 3(EN1993-1-5), the DASt Richtlinie 015 and Jáger et al. In case these prove to be inaccurate, a design model is developed. The results of the comparisons generally showed that the method of approxi mating the buckling coefficient and …
-
Behaviour of unstiffened flush end plate beam-to-column connections in structural steelwork
… results obtained by applying the design rules of Eurocode 3 was made.<br/><br/>By comparing the experimental results with the analytical results using finite element method, it was found that the finite element method was quite capable of tackling the complex problem of flush end plate …
-
Nouvelle approche de la classification par rigidité des assemblages poutre-colonne en construction métallique
… The current criterion mentioned in Eurocode 3, part 1-8, is very approximate. Some joints are therefore classified as semi-rigid or stiffened, which increases their cost, even if they are actually already rigid. The purpose of this work is to define a new, less restrictive but still …
-
Nonlinear finite element analysis of stainless steel corrugated web girders subjected to patch loading
… models and the formula from the newest draft of Eurocode 3 to examine its validity and accuracy level for stainless steel corrugated web girders. The results showed that the Eurocode 3 formula was very conservative and none of the other available design models analyzed in this study were …
-
DESIGN OF COMPOSITE END-PLATE CONNECTIONS
… in accordance with the most modern code, Eurocode 3 (1992). A design procedure is given in the Annex J of Eurocode 3 ( hereafter: EC 3) for the joint type studied in this thesis. Since EC 3 has not been put into practice yet, it is calling for a wide-range of discussion for its future use …
-
Vulnerability assessment of extended end-plate connections under mainshock-aftershock sequences
… mechanical models in accordance with Eurocode 3 were developed to simulate the behavior of extended end-plate connections under mainshock-aftershock loading in this study. An understrength factor was developed in order to account for the inherent conservatism within Eurocode 3. For the …
-
Υπολογισμός μεταλλικών φορέων με ημιάκαμπτες συνδέσεις
… the classification according to the Annex J of Eurocode 3 is performed. Following this, a fine meshed three-dimensional finite element model is developed to describe this specific joint. Based on this model, a series of parametric analyses is conducted. Finally, a comparison between the Eurocode …
-
Development of plastic design procedures for stainless steel indeterminate structures
… structures is currently not permitted by Eurocode 3: Part 1.4 despite the excellent material ductility and the existence of a Class 1 slenderness limit, thereby compromising design efficiency. This dissertation focuses on the structural behaviour and design of stainless steel continuous …
-
Colapso por flexo-torção de colunas de aço formadas a frio sob temperaturas elevadas :resistência última e dimensionamento via MRD
… The steel is simulated by models prescribed in Eurocode 3: part 1.2. The numerical failure loads obtained in this research and collected in the international literature were used to validated the efficiency of DSM and to propose a modification, making it capable of handling flexural torsional …
-
Influência da flexibilidade das ligações no projeto de estruturas metálicas
… embasados nos métodos descritos pelo anexo J do Eurocode 3 e recomendações do BCSA/SCI. Com intuito de automatizar o cálculo das conexões semi-rígidas foi implementado um programa computacional que fornece as propriedades necessárias das ligações entre vigas e pilares através da entrada de dados …
-
Behaviour, optimisation and design of cold-formed steel purlins
… assess the accuracy of the design predictions of Eurocode 3 and the Direct strength method (DSM). On the other hand, Sigma sections employ a non-flat web which offers greater strength against local and distortional buckling at the expense of reduced resistance to web crippling. Furthermore, …
-
Behaviours of steel connections with unfitted stiffeners
… be applied in design calculations according to Eurocode 3 to adjust for the effects of stiffener gaps.<br/><br/>Key results indicate that adding fitted stiffeners significantly enhances connection performance, reducing maximum stresses and improving load-bearing capacity. While stiffeners with …
Page 1 of 3