  1. Structural Behaviour of Concrete Filled Steel Tubes With High Strength Materials.

    … For evaluation, test results were compared with Eurocode 4 predictions. It was found that ultra-high resistance could be achieved. Therefore, they are most suitable to be applied in high-rise constructions. It was also found that Eurocode 4 limitations on materials can be extended to UHSC and HSS …

    nus Repository record for Structural Behaviour of Concrete Filled Steel Tubes With High Strength Materials. (opens in a new tab) Download file for Structural Behaviour of Concrete Filled Steel Tubes With High Strength Materials. (opens in a new tab)

  2. Composite columns

    … The design methods according to AISC and Eurocode 4 are summarized and provide a procedure to design a composite column. In addition, equation are derived to determine the nominal flexural strength of typical composite cross-sections.

    njit Repository record for Composite columns (opens in a new tab)

  3. Behaviour of demountable shear connectors in composite structures

    … used for the welded shear connections given in Eurocode 4 and AISC 360-10 and the methods used for bolted connections in Eurocode 3 and ACI 318-08. It was found that the AISC 360-10 and ACI 318-08 methods overestimated the shear capacity in some cases. The Eurocode method is conservative and can …

    bradford Repository record for Behaviour of demountable shear connectors in composite structures (opens in a new tab)

  4. HEADED STUD SHEAR CONNECTORS IN FULL-SIZE COMPOSITE BEAMS WITH WIDE RIBBED METAL DECK

    … approximately 61%. The corresponding values for Eurocode 4 were 10% and 19%, respectively. The test results indicated an increase of 17 % in the shear strength per stud when the longitudinal stud spacing was changed from 3 to 8 times the stud diameter. The longitudinal stud spacing greatly …

    sask Repository record for HEADED STUD SHEAR CONNECTORS IN FULL-SIZE COMPOSITE BEAMS WITH WIDE RIBBED METAL DECK (opens in a new tab)

  5. SEMI-RIGID BEAM-TO-BEAM COMPOSITE JOINT FOR LONG SPAN COMPOSITE FLOOR BEAM

    … predictions based on the component method in Eurocode 4. According to these studies, it was revealed that the reasonable moment - rotation characteristics of BBCJs can be obtained by the component method to which the proposed effective width and effective length are applied. In addition, this …

    nus Repository record for SEMI-RIGID BEAM-TO-BEAM COMPOSITE JOINT FOR LONG SPAN COMPOSITE FLOOR BEAM (opens in a new tab) Download file for SEMI-RIGID BEAM-TO-BEAM COMPOSITE JOINT FOR LONG SPAN COMPOSITE FLOOR BEAM (opens in a new tab)

  6. Structural response of stainless steel composite bridge beams with welded shear studs

    … weld quality. Eight push-out tests according to Eurocode 4 were conducted; three with carbon steel studs, and five with austenitic EN 1.4301 studs, welded to lean duplex EN 1.4162 beams. A validated numerical model was used to conduct a parametric study on stainless steel welded shear studs in …

    soton Repository record for Structural response of stainless steel composite bridge beams with welded shear studs (opens in a new tab) Download PDF for Structural response of stainless steel composite bridge beams with welded shear studs (opens in a new tab)

  7. ULTIMATE STRENGTH BEHAVIOUR OF LIGHTWEIGHT STEEL-CONCRETE-STEEL SANDWICH COMPOSITE PANELS AND WALLS

    … effect. A new N-M interaction model based on Eurocode 4 method is developed to predict the ultimate resistance of SCS sandwich wall subjected to compression and end moments. The accuracy of the proposed methods is established by comparing the predicted results with those obtained from FE and …

    nus Repository record for ULTIMATE STRENGTH BEHAVIOUR OF LIGHTWEIGHT STEEL-CONCRETE-STEEL SANDWICH COMPOSITE PANELS AND WALLS (opens in a new tab) Download file for ULTIMATE STRENGTH BEHAVIOUR OF LIGHTWEIGHT STEEL-CONCRETE-STEEL SANDWICH COMPOSITE PANELS AND WALLS (opens in a new tab)

  8. A Database for Composite Columns

    … provision for composite columns (AISC 1999 and Eurocode 4), and reassessed by the upcoming 2005 AISC specification. The data indicates that the Eurocode gives good predictions for columns and the AISC 2005 method performs very well for beam-columns. For rectangular CFT columns, all three methods …

    gatech Repository record for A Database for Composite Columns (opens in a new tab)

  9. Buckling of slender composite piles in soft soils - A comparative study between the Swedish analytical method and 3D Finite Element

    … steel and concrete, are designed according to Eurocode 4 "Design of composite structures". While the Swedish analytical method consider the plastification of the surrounding soil with elastic conditions in the pile member. These assumption in both methods rises the question of how to design for …

    chalmers Repository record for Buckling of slender composite piles in soft soils - A comparative study between the Swedish analytical method and 3D Finite Element (opens in a new tab)

  10. Αριθμητική και πειραματική μελέτη της διεπιφάνειας χάλυβα - σκυροδέματος στις σύμμικτες πλάκες με χαλυβδόφυλλο μορφής

    … according to the rules and the restrictions of Eurocode 4. The experimental results have been processed by using the PSC method. The theoretical curve of the composite slab according to the Partial Shear Connection method has also been constructed. For the computational treatment of the problem, …

    greece Repository record for Αριθμητική και πειραματική μελέτη της διεπιφάνειας χάλυβα - σκυροδέματος στις σύμμικτες πλάκες με χαλυβδόφυλλο μορφής (opens in a new tab)

  11. Análise de estrutura de piso misto formado por vigas treliçadas em perfis formados a frio e lajes pré-moldadas de concreto

    … to the recommendations established by the Eurocode 4, and full-scale bending tests. The experimental results indicated that the connectors are adequate, in terms of resistant capacity and deformation capacity (ductility), to ensure full interaction between the steel trusses and the one-way …

    brazil-uerj Repository record for Análise de estrutura de piso misto formado por vigas treliçadas em perfis formados a frio e lajes pré-moldadas de concreto (opens in a new tab)

  12. Behaviour of elliptical concrete-filled steel tube (CFT) columns under axial compression load

    … a review of the existing design standards of Eurocode 4 (EC4) and American Specifications (AISC). The design expressions from these current design provisions for circular, square and rectangular concrete- filled tubes design strengths were used to predict the capacities of elliptical eFT …

    whiterose Download PDF for Behaviour of elliptical concrete-filled steel tube (CFT) columns under axial compression load (opens in a new tab)

  13. Comparative study of strength design methods for rectangular reinforced concrete and composite steel-concrete columns

    … 1984), the AISC-LRFD Specifications (1994), Eurocode 2 (Design 1992), and Eurocode 4 (Design 1994). The results of a finite element modelling (FEM) procedure were also compared by using a commercially available nonlinear FEM software (ABAQUS 1994a, 1994b). The columns used for comparison in …

    manitoba Repository record for Comparative study of strength design methods for rectangular reinforced concrete and composite steel-concrete columns (opens in a new tab)

  14. Behaviour of elliptical tube columns filled with self-compacting concrete

    … those predicted using simple methods provided in Eurocode 4 for concrete-filled steel rectangular tube columns showed a reasonable agreement. The proposed three dimensional FE model accurately predicted the failure modes, the load capacity and the load-deflection response of the columns tested. …

    bradford Repository record for Behaviour of elliptical tube columns filled with self-compacting concrete (opens in a new tab)

  15. The behaviour of profiled steel sheet/concrete slabs

    … regression approach of British Standards and the Eurocode 4. Comparison is made with the design values using the partial interaction method. The comparison indicates that both design methods are valid with the regression approach being slightly more conservative. Finite element methods and their …

    salford Download PDF for The behaviour of profiled steel sheet/concrete slabs (opens in a new tab)

  16. STRUCTURAL BEHAVIOUR AND DESIGN OF ALUMINIUM ALLOY-CONCRETE COMPOSITE STRUCTURAL MEMBERS

    … purposes and to assess the applicability of Eurocode 9 design standard. The experimental investigation of CFDSAT structural members includes 8 columns and 10 beams. The column tests are conducted using a pin-ended set-up for allowing the specimens to rotate around the buckling axis. The …

    liverpool-jm Repository record for STRUCTURAL BEHAVIOUR AND DESIGN OF ALUMINIUM ALLOY-CONCRETE COMPOSITE STRUCTURAL MEMBERS (opens in a new tab) Download PDF for STRUCTURAL BEHAVIOUR AND DESIGN OF ALUMINIUM ALLOY-CONCRETE COMPOSITE STRUCTURAL MEMBERS (opens in a new tab)

  17. Design and Behavior of Composite Steel-Concrete Flexural Members with a Focus on Shear Connectors

    … determining the strength of composite beams in Eurocode 4 (CEN 1992) and 1999 AISC Specification (AISC 1999) differ in many respects. This is particularly true when considering the design of shear connections. This part of the dissertation explores those differences through a comparative …

    vt Repository record for Design and Behavior of Composite Steel-Concrete Flexural Members with a Focus on Shear Connectors (opens in a new tab)

  18. DESIGN OF COMPOSITE END-PLATE CONNECTIONS

    … in accordance with the most modern code, Eurocode 3 (1992). A design procedure is given in the Annex J of Eurocode 3 ( hereafter: EC 3) for the joint type studied in this thesis. Since EC 3 has not been put into practice yet, it is calling for a wide-range of discussion for its future use …

    nus Repository record for DESIGN OF COMPOSITE END-PLATE CONNECTIONS (opens in a new tab) Download file for DESIGN OF COMPOSITE END-PLATE CONNECTIONS (opens in a new tab)

  19. ESTUDIO NUMÉRICO DE LA CAPACIDAD PORTANTE DE COLUMNAS MIXTAS CON DOBLE TUBO RELLENAS DE HORMIGON

    … calculation method for composite columns in Eurocode 4-Part 1.1, in order to evaluate the validity of the method for double-tube columns subjected to axial compression and combined compression and uniaxial bending, infilled with ultra-high strength concrete. The scope of this thesis is …

    upv Repository record for ESTUDIO NUMÉRICO DE LA CAPACIDAD PORTANTE DE COLUMNAS MIXTAS CON DOBLE TUBO RELLENAS DE HORMIGON (opens in a new tab)

  20. FIRE RESPONSE ANALYSIS OF CIRCULAR CONCRETE FILLED TUBULAR COLUMNS AND THE EFFECTS OF AXIAL AND ROTATIONAL RESTRAINTS

    … developing a simple calculation method based on Eurocode 4 and using the concept of equivalent concrete core cross-section. Finally, given the reduced computational cost of the fiber model, the effects of axial and rotational restraint in the fire response of CFT columns are investigated by …

    upv Repository record for FIRE RESPONSE ANALYSIS OF CIRCULAR CONCRETE FILLED TUBULAR COLUMNS AND THE EFFECTS OF AXIAL AND ROTATIONAL RESTRAINTS (opens in a new tab)