Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 25 for “"Eurocode 5"”

  1. Stiffness of Bolted Timber Connection

    … equation for connections using fasteners in Eurocode 5 is specified as a function of wood density and fastener diameter only. In this research, an analysis of available data sets on various configurations of tested bolted steel-wood-steel (SWS) connections loaded in tension parallel to grain …

    auckland-ms Repository record for Stiffness of Bolted Timber Connection (opens in a new tab)

  2. Combined loading of angled screws in timber connections A study to evaluate the stiffness and load-carrying capacity of inclined screws

    … with inclined screws are underestimated by Eurocode 5 in general but especially when considering certain angles. This does still remain true with the second generation of Eurocode 5. The research does however demonstrate that the use of inclined screws can significantly increase the …

    chalmers Repository record for Combined loading of angled screws in timber connections A study to evaluate the stiffness and load-carrying capacity of inclined screws (opens in a new tab)

  3. Experimentální a numerická analýza spřažených dřevobetonových konstrukcí

    … vzorcích. Dále byl proveden ruční výpočet podle Eurocode 5 zkoušených prvků a v programu Asteres byly namodelovány tři varianty zkušebních prvků s různými hodnotami tuhosti spřažení podle pracovního diagramu spřahovacích prostředků. Na závěr byly porovnány experimentální, výpočetní a numerické …

    brno-tech Repository record for Experimentální a numerická analýza spřažených dřevobetonových konstrukcí (opens in a new tab)

  4. Fracture behaviour of acetylated wood : Material characterisation and dowel-type connections

    … pine were studied. Results were compared to Eurocode 5 estimations to evaluate the validity of current design provisions for acetylated wood. It was found that, for all the tested enddistances for loading parallel to the grain, joints made from acetylated wood failed in a brittle manner. …

    lund Repository record for Fracture behaviour of acetylated wood : Material characterisation and dowel-type connections (opens in a new tab)

  5. Entwurf eines HBV-Deckensystems für Anwendungen im Neubau

    … Deckensystems auf der normativen Grundlage des Eurocode 5 werden teilweise vom Regelwerk abweichende Ansätze begründet. Außerdem wird dieses System in wirtschaftlicher und ökologischer Hinsicht bewertet.

    qucosa-diss Repository record for Entwurf eines HBV-Deckensystems für Anwendungen im Neubau (opens in a new tab)

  6. Structural Assessment of Glued-Laminated Timber Columns Subjected to Real Fires

    … rates and rates predicted by CSA O86 (2019), and Eurocode 5 (2004). Uneven charring and adhesive degradation were significant factors affecting post-fire performance. Despite extensive charring, the columns retained much of their structural integrity, supporting potential repairs over replacement. …

    carleton Repository record for Structural Assessment of Glued-Laminated Timber Columns Subjected to Real Fires (opens in a new tab)

  7. Untersuchungen an Verbindungselementen für Holzkonstruktionen im Maschinen- und Anlagenbau

    … eingegangen, schwerpunktmäßig durch die im Eurocode 5 (DIN EN 1995) definierten Modelle für stiftförmige Verbindungsmittel. Im zweiten, praktischen Teil der Arbeit erfolgt die Durchführung und Auswertung umfangreicher Versuche. Dabei werden in einem ersten Schritt wesentliche …

    qucosa-diss Repository record for Untersuchungen an Verbindungselementen für Holzkonstruktionen im Maschinen- und Anlagenbau (opens in a new tab)

  8. Impact of connections on the system behaviour and reliability of timber - Nonlinear Finite Element analyses of laterally loaded CLT wall

    … analyses and the design approach according to Eurocode 5 show that the first connection in the wall system is the most important one in terms of global load-carrying capacity. The nonlinear analyses show that when the maximum load is reached in the first connection, the load is redistributed to …

    chalmers Repository record for Impact of connections on the system behaviour and reliability of timber - Nonlinear Finite Element analyses of laterally loaded CLT wall (opens in a new tab)

  9. Development of Empirical Model of Shear Force Capacity and Stiffness of the Screw Connections in Timber – Concrete Composite Structures

    … was carried out due to some limitations found in Eurocode 5 (EC5) and existing predictive strength and slip modulus models of screw connections. One deficiency seen in these models is the neglect of consideration of the local characteristics of the screw embedded within the concrete on the …

    bristol Repository record for Development of Empirical Model of Shear Force Capacity and Stiffness of the Screw Connections in Timber – Concrete Composite Structures (opens in a new tab)

  10. Évaluation du comportement en vibration et optimisation de la conception des planchers composite en bois lamellé collé croisé-béton

    … analytiques, dont une est proposée par la norme Eurocode 5, ainsi qu’un modèle simplifié par éléments finis ont donné de bonnes estimations des fréquences naturelles mesurées. Pourtant, une calibration des modules des panneaux en bois lamellé collé croisé due à l’impact des entailles a été …

    star-france Repository record for Évaluation du comportement en vibration et optimisation de la conception des planchers composite en bois lamellé collé croisé-béton (opens in a new tab)

  11. Experimental and numerical uncertain vibration analysis of multilayered timber structures assembled using compressed wood dowels

    … au regard des critères de conception exigés par Eurocode 5 en ce qui concerne le confort vibratoire des planchers bois. Un modèle EF simplifié a ensuite été développé pour réduire les coûts de calcul. Le niveau de variabilité des résultats des AFEWP a été également étudié et discuté. La …

    star-france Repository record for Experimental and numerical uncertain vibration analysis of multilayered timber structures assembled using compressed wood dowels (opens in a new tab)

  12. Assessing the Fire Integrity Performance of Cross-Laminated Timber Floor Panel-to-Panel Joints

    … joints using simple analytical models, such as Eurocode 5: Part 1-2. The contribution of this study is to increase the knowledge of CLT exposed to fire and to facilitate its use in Canada and US by complementing current fire-resistance design methodologies of CLT assemblies, namely with respect …

    carleton Repository record for Assessing the Fire Integrity Performance of Cross-Laminated Timber Floor Panel-to-Panel Joints (opens in a new tab)

  13. Long-term behaviour of Timber Concrete Composite elements - Finite element study of long-term deflections caused by creep and shrinkage

    … aspect. The design approach presented in Eurocode 5 is based on an analytical calculation method called the γ-method (“gamma”-method). There, an effective cross-sectional stiffness is calculated based on the interaction degree between the timber and con crete. The γ-method has several …

    chalmers Repository record for Long-term behaviour of Timber Concrete Composite elements - Finite element study of long-term deflections caused by creep and shrinkage (opens in a new tab)

  14. Comportamento estrutural de painéis Cross-Laminated Timber sob cargas perpendiculares ao seu plano : abordagem experimental e numérica

    … Tendo em vista que as normas, NBR 7190 e Eurocode 5, encontramse atualmente em revisão para incluir esse produto de madeira engenheirada, ainda encontramse diversos focos de estudo na medida em que a arquitetura ganha confiança nesse material. Uma situação de carregamento que chama a …

    brazil-ufrgs Repository record for Comportamento estrutural de painéis Cross-Laminated Timber sob cargas perpendiculares ao seu plano : abordagem experimental e numérica (opens in a new tab)

  15. Robustness of multi-story timber buildings in seismic regions

    … indicate that the detailing requirements of Eurocode 5 and Eurocode 8 are su cient to achieve the required performance, even though they also indicate that these requirements can be optimized to achieve more cost-e ective connections and members. Finally, the progressive collapse potential of …

    minho-thes Repository record for Robustness of multi-story timber buildings in seismic regions (opens in a new tab)

  16. Stiffness of dowel-type timber connections and its influence on structures Finite element analysis of high performance timber connections and their impact in a case study

    … for evaluating stiffness in standards such as Eurocode 5 are limited. For this reason, detailed information on stiffness and ductility of connections might be neglected in design process. This might results in inefficient material utilisation and unknown effects. Therefor, the aim of this …

    chalmers Repository record for Stiffness of dowel-type timber connections and its influence on structures Finite element analysis of high performance timber connections and their impact in a case study (opens in a new tab)

  17. Comportement thermo-hygro-mécanique différé des feuillus : des sciences du bois à l'ingénierie

    … Génie Civil, est régie par la norme Européenne Eurocode 5. Elle permet de dimensionner tout élément de structure en fonction du chargement qui lui est appliqué et d’hypothèses relatives à son environnement. Coordonnée particulièrement par la filière bois des pays Nordiques, cette norme est basée …

    star-france Repository record for Comportement thermo-hygro-mécanique différé des feuillus : des sciences du bois à l'ingénierie (opens in a new tab)

  18. Evaluation and Calibration of Pedestrian Bridge Standards for Vibration Serviceability

    … and Europe are evaluated, including ISO 10137, Eurocode 5, the British National Annex to Eurocode 1, and SÉTRA. The experimental program was undertaken on three full-scale aluminum pedestrian bridges; one in the field and two in the laboratory. Aluminum structures provide a high …

    waterloo Repository record for Evaluation and Calibration of Pedestrian Bridge Standards for Vibration Serviceability (opens in a new tab)

  19. Optimisation du dimensionnement des structures en bois en fonction de l'humidité

    … cette sensibilité aux variations climatiques, l'Eurocode bois considère trois classes de service définies par rapport aux conditions climatiques extérieures. Ces classes de service induisent au niveau des règles de dimensionnement des coefficients correcteurs pour les propriétés mécaniques, les …

    star-france Repository record for Optimisation du dimensionnement des structures en bois en fonction de l'humidité (opens in a new tab)

  20. Comportement Thermo-Hygro-Mécanique du bois soumis à des sollicitations accidentelles d'incendie

    … par sa teneur en humidité. Bien que l'Eurocode 5 intègre certains aspects climatiques dans la conception des structures en bois, il néglige l'influence de l'humidité et des gradients hydriques pouvant se développer à l'intérieur du matériau, altérant ainsi ses performances mécaniques. …

    star-france Repository record for Comportement Thermo-Hygro-Mécanique du bois soumis à des sollicitations accidentelles d'incendie (opens in a new tab)

Page 1 of 2