Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 51 for “"Eurocode 8"”.
-
Seismic actions in the context of the Eurocode 8 revision and risk assessment of urban areas and critical infrastructure
… design actions in the upcoming revision of Eurocode 8, the European standard for seismic design, and on the other hand, to validate and apply seismic hazard and risk models for the assessment of urban environment and critical infrastructure. Combined, these two pillars provide a …
-
Líkangerð og mat á áraun á byggingu í Suðurlandsskjálfta 2008
… jarðskjálftaálags og þau skoðuð í samhengi við Eurocode 8 staðalinn. Einfalt líkan af tveggja hæða steinsteyptri veggjabyggingu er sett upp í FEM-forriti, líkt er eftir undirstöðum með gormaeiningum og gerð á því álagsgreining en burðarkerfi byggingarinnar hefði átt að skemmast í …
-
Analýza výškové budovy na účinky zemětřesení
… pomocí spektra odezvy v souladu s normou Eurocode 8. Výsledky obou modelů byly vzájemně porovnány a byly posouzeny možnosti jejich praktického využití.
-
Performance-Based Evaluation and Design of Cold-Formed Steel Lateral Force-Resisting Systems for Multi-Storey Buildings
… strap-braced frame, designed in accordance with Eurocode 8 specifications, exhibited very low ductility at some storey levels, below the target value of 4, while the design solution following the proposed methodology reached high ductility, preventing premature failure of the chord studs. The …
-
Ενίσχυση υφιστάμενων πλαισιακών κατασκευών με εμφάτνωση από Ο.Σ.: πειραματική και αναλυτική διερεύνηση
… frame. Because of this lack of knowledge, Eurocode 8 - Part 3 does not cover this technique. The Greek code for Structural Interventions (Kan.Epe.) refers to the dimensioning of these walls only in terms of forces and does not provide means for calculating deformation at yielding and …
-
Πολυκριτηριακή επιλογή ισχυρών εδαφικών κινήσεων για την αξιόπιστη εκτίμηση της σεισμικής απόκρισης των κατασκευών
… The first step was to assess the impact of Eurocode 8-based earthquake records selection procedure on the nonlinear response of a multi-storey, irregular reinforced concrete (R/C) building. The highly scattered inelastic response results highlighted the adverse implications of code-conformed …
-
Πειραματική διερεύνηση της συμπεριφοράς δοκών από σκυρόδεμα ενισχυμένων με πολυμερή οπλισμένα με χάλυβα ή άνθρακα
… of the specimens and by the use of ACI, Eurocode 8- part 3 and KAN.EPE provisions.
-
STUDY OF THE SEISMIC BEHAVIOUR OF REINFORCED CONCRETE FRAMES HAVING VERTICAL IRREGULARITIES
… EVALUATE THE ADEQUACY OFTHE DESIGN PROVISIONS IN EUROCODE 8 WITH REGARD TO THE BEHAVIOUR (G) FACTOR AND DUCTILITY. COVERED IN THIS THESIS ARE TWO SIX-STORY THREE-BAY FRAMES, ONE HAVING A TALL FIRST STORY (FRAME BF 1), AND THE OTHER HAVING A DISCONTINUING COLUMN (FRAME DCF). THE FRAMES WERE …
-
Numerical modelling of reinforced concrete bridge pier under artificially generated earthquake time-histories
… earthquake time-histories (AGETH) fitting to a Eurocode 8 (EC8) response spectrum are randomly generated using SIMQKE software and the average generated spectrum compares well with the EC8 one. Two Finite element (FE) smeared crack models, named Multi-crack and Craft, are well validated against …
-
Seismic response of acceleration-sensitive non-structural components mounted on irregular multi-storey reinforced concrete buildings
… of the NSCs and to evaluate the accuracy of Eurocode 8 (EC8) predictions when the NSCs are attached to the flexible sides along the heights of the primary structures (P-structures). Various sets of natural and artificial earthquake records consisting of 70 accelerograms were utilised. The …
-
Stochastic Modelling and Analysis for Bridges under Spatially Varying Ground Motions
… in modern seismic codes has been impeded. Eurocode 8 is currently the only seismic standard worldwide that gives a set of detailed guidelines to explicitly tackle spatial variabilities of ground motions in bridge design, providing both a simplified design scheme and an analytical approach. …
-
Near-fault ground motions and structural design issues
… spectra and their comparison with shapes of Eurocode 8 spectra, an introduction to inelastic behaviour of elastic-perfectly-plastic (EPP) SDOF systems is presented using models relating structural behaviour factor and displacement ductility. Finally other types of inelastic hysteretic …
-
Seismic Assessment, Repair and Retrofit of Existing Corroded Structures Using UHPC Jacketing
… event. Current assessment guidelines such as Eurocode 8-III or ASCE 41-17 take the lack of detailing into consideration in the assessment procedure however, they do not address a major concern, reinforcement corrosion. In this dissertation, modifications to current assessment guidelines were …
-
Development of procedures for real-time hybrid simulation and testing of a buckling-restrained braced structure
… response of realistic structures designed to Eurocode 8. Finally, the system was applied to RTHS with a viscoelastic damper, demonstrating the versatility of the adaptive system.
-
The behaviour of integral bridges undervertical and horizontal earthquake ground motion
… abutment bridge. The study is made based on Eurocode 8 recommendations, which provides data for different types of soil to be used for earthquake analysis. A symmetrical medium length integral bridge obtained from an existing structure is used for the analysis. Artificial EC8 spectrum …
-
Linear and Nonlinear Structure-Soil-Structure Interaction During Earthquakes
… The ground motion is spectrally matched with Eurocode-8 elastic spectra. Results show that the SSSI effects could be more pronounced when the nonlinear behaviour is considered.<br/>Chapter 6 presents a 3D model of SSSI between multiple buildings which shortens computational run-times for large …
-
Linear Time-History Analysis as EC8-compliant Design Method for Simplified Performance-Based Earthquake Engineering Assessment
… earthquake engineering but many codes, including Eurocode 8 (EC8), do not mention explicitly LTHA among the possible methods of analysis for design. LTHA can represent a simplified tool for engineers avoiding the complexity of nonlinear models for advanced analyses as well as approximate …
-
Response of linear-elastic structures to near-fault ground motions
… as the total height of the frames increased. The Eurocode 8 (EC8) storey force distribution approximates the dynamic behaviour by considering only a single mode. Results from time history analysis suggests that for near-fault sites the linear distribution of equivalent static storey forces in EC8 …
-
Seismic analysis of knee elements for steel frames
… with different pushover analysis methods (Eurocode 8, FEMA-356 and ATC-40) have been compared to those obtained wit the time history analyses. Moreover FEMA-356 method, which includes a more accurate representation of the structure's significant post-yield stiffness, gave the closest …
-
Finite element seismic analysis of guyed masts
… are also undertaken. Applicable sections of Eurocode 8 are followed wherever possible. It is shown that when subjected to substantial seismic events with peak ground accelerations in the region of 4m/s2, significant forces can develop in masts that are comparable to those produced during a …
Page 1 of 3