Desenvolvimento e caracterização de um compósito matriz metálica (CMM): aço EUROFER97 reforçado com Carbeto de Tântalo - TaC
Steel is an alloy EUROFER promising for use in nuclear reactors, or in applications where the material is subjected to temperatures up to 550 ° C due to their lower creep resistance under. One way to increase this property, so that the steel work at higher temperatures it is necessary to prevent …
-
Characterisation and development of advanced structural alloys for nuclear fusion reactors
… reduced activation ferritic martensitic steel EUROFER97, an oxide dispersion strengthened variant of EUROFER97, and the vanadium alloy, V-4Cr-4Ti. In this work high energy synchrotron X-ray diffraction during tensile testing is employed to characterise the microstructural evolution of these …
-
Interactions between irradiation defects and solute atoms in ferritic steels based on the binary Fe-Cr system
… RAFM steel proposed for this purpose is “Eurofer97”, a material developed in European research laboratories. RAFM steels exhibit some key mechanical properties and high resistance to radiation damage accumulation under irradiation. However, besides their many advantageous properties, their …
-
Určování lomově-mechanických charakteristik z podrozměrných zkušebních těles
… vyvinuté pro jaderný a energetický průmysl, ocel Eurofer97 a ODS ocel MA956. Za účelem hodnocení a interpretace napěťově deformačního stavu na čele trhliny ve zkoušených tělesech pro ocel Eurofer97 byly realizovány simulace provedených testů pomocí metody konečných prvků a pomocí mikromechanického …
-
Irradiation effects on the deformation of oxide dispersion strengthened steels
… steels (Fe-14wt%Cr and a European standard alloy EUROFER97) and two equivalent Oxide Dispersion Strengthened (ODS) steels (Fe-14wt%Cr ODS (CEA ODS) and EUROFER ODS).</p> <p>Neutron irradiation of the samples was impractical due to timescale and specific handling requirements for radioactive …
-
Finite Element Modelling of the Small Punch Test for Structure Critical Design
… materials and damage model parameters of P91 and Eurofer97 steels at room temperature. An effective method for the optimisation of the Johnson-Cook materials model parameters was developed. This method utilised the scripting capabilities of Abaqus in conjunction with the SciPy optimise module …