Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"Evaporator performance"”.

  1. Nucleate pool boiling of R-114 and R-114/oil mixtures from single enhanced tubes

    … overall cycle efficiency, the heat transfer performance in the evaporator can be improved by using enhanced boiling surfaces. This thesis looks at the pool boiling characteristics of R-114 (presently used in large shipboard AC systems) from 10 enhanced single copper tubes and compares …

    nps Repository record for Nucleate pool boiling of R-114 and R-114/oil mixtures from single enhanced tubes (opens in a new tab)

  2. EXPERIMENTAL INVESTIGATION OF THE THERMAL PERFORMANCE OF VERTICAL AND ELBOW THERMOSYPHONS

    The thermal performance of two thermosyphons with different geometries was experimentally investigated in this study. The first thermosyphon utilized a 310 mm long vertical evaporator and a 385 mm long condenser section that was inclined at 5 degrees from the vertical. The second was an elbow …

    mcmaster Repository record for EXPERIMENTAL INVESTIGATION OF THE THERMAL PERFORMANCE OF VERTICAL AND ELBOW THERMOSYPHONS (opens in a new tab)

  3. INVESTIGATION OF PERFORMANCE DEGRADATION OF EVAPORATOR FOR LOW TEMPERATURE REFRIGERATION APPLICATIONS

    An evaporator test stand has been designed, sized, constructed, calibrated and operated to investigate the evaporator performance degradation for low temperature refrigeration applications. Measurements have been taken of air- and refrigerant-side temperatures, refrigerant-side pressures, air- and …

    maryland Repository record for INVESTIGATION OF PERFORMANCE DEGRADATION OF EVAPORATOR FOR LOW TEMPERATURE REFRIGERATION APPLICATIONS (opens in a new tab)

  4. Experimental and numerical investigation of the design and control of vapor-compression systems with integration of two-phase ejectors for performance enhancement through expansion work recovery

    … Research has focused primarily on the design and performance of the ejector and the effect the ejector has on cycle performance. However, recent research has shown that additional factors, such as cycle architecture, improvement in evaporator performance, and cycle control, can also have …

    uiuc Repository record for Experimental and numerical investigation of the design and control of vapor-compression systems with integration of two-phase ejectors for performance enhancement through expansion work recovery (opens in a new tab)

  5. Theoretical analysis and experimental investigation of ejector heat pumps and its water heating applications

    … applications. The main goal is to improve performance, identify environmentally friendly working fluids, and determine how EHP technology can be applied to residential and commercial heating systems. The work combines analytical modeling, refrigerant screening, ejector geometry studies, and …

    missouri Repository record for Theoretical analysis and experimental investigation of ejector heat pumps and its water heating applications (opens in a new tab) Embargoed until 2026-12-01

  6. Enhanced Two-Phase Heat Spreading Enabled by Dropwise Condensation

    … condensation in vapor chambers, the thermal performance and scalability can be further improved due to the enhanced condensation heat transfer and unique droplet dynamics. However, an industrial-ready dropwise vapor chamber has yet to be developed mainly due to the lack of feasible dropwise …

    south-carolina Repository record for Enhanced Two-Phase Heat Spreading Enabled by Dropwise Condensation (opens in a new tab)

  7. Investigation and analysis of lubricant effects on the performance of an HFC-134a refrigeration system

    … and viscosity were evaluated by measuring the performance of an HFC-134a refrigeration system. The focus of this study is different from past studies which have been based on investigating system reliability in that is based on evaluating system efficiency, i.e., coefficient of performance;The …

    iastate Repository record for Investigation and analysis of lubricant effects on the performance of an HFC-134a refrigeration system (opens in a new tab)

  8. Experimental and modeling study of lubricant effect on refrigerant distribution in microchannel evaporators

    … can significantly deteriorate the performance of heat exchanger (especially evaporator) and system. In real air conditioning systems especially automobile air conditioning systems where oil separator is less commonly used, the lubricant pumped out of the compressor is mixed with …

    uiuc Repository record for Experimental and modeling study of lubricant effect on refrigerant distribution in microchannel evaporators (opens in a new tab)

  9. Characteristics of heat transfer fouling of thin stillage using model thin stillage and evaporator concentrates

    … wet grains and liquid fraction as thin stillage. Evaporator fouling occurs during thin stillage concentration to syrup and decreases evaporator performance. Evaporators need to be shutdown to clean the deposits from the evaporator surfaces. Scheduled and unscheduled evaporator shutdowns decrease …

    uiuc Repository record for Characteristics of heat transfer fouling of thin stillage using model thin stillage and evaporator concentrates (opens in a new tab)

  10. Flash gas bypass - a way to improve distribution of adiabatic two-phase refrigerant flow in headers of microchannel evaporators

    … phase adiabatic flow in headers of parallel flow evaporators, of typically microchannel design. Three main issues that will be explored in this thesis are: 1) separation of vapor-liquid refrigerant immediately after an expansion device in a compact T-junction and design options to enhance its …

    uiuc Repository record for Flash gas bypass - a way to improve distribution of adiabatic two-phase refrigerant flow in headers of microchannel evaporators (opens in a new tab)