Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 455 for “"Excimer"”.
-
BROADBAND TUNABLE EXCIMER LASER STUDIES
… has been the studies of the broadband tunable excimer laser namely XeF(C $\to$ A). Wideband tunability of this excimer laser was first demonstrated with a simple compact dispersive stable cavity in a transverse e-beam pumped geometry. More recently, a series of experiments has been performed to …
-
Microhollow Cathode Discharge Excimer Lamps
… pressures favors three body processes such as excimer formation. This was confirmed by experiments in xenon and argon where emission of excimer radiation at 172 nm and 130 nm, respectively, was observed when the pressure was increased beyond 50 Torr. The intensity of excimer radiation in xenon …
-
ELECTRON BEAM PUMPED TUNABLE EXCIMER LASERS
… extensively for the broadband rare gas halide excimers Xe(,2)Cl, Kr(,2)F, and XeF (C(--->)A). The trimer Kr(,2)F was first observed to lase during these investigations, while Xe(,2)Cl and XeF (C(--->)A) had been previously demonstrated. Since all three excimers have unbound ground states, a …
-
Excimer laser microlithography at 193 NM
None provided.
-
Photoassociative excitation spectroscopy of excimer molecules
… states was explored as a tool for the study of excimer molecules. Since the repulsive nature of the ground state constrains collision pairs to large internuclear transitions, bound $\gets$ free excitation spectra contain more structure than the bound $\to$ free fluorescence spectra for the same …
-
Continuous microwave excitation of excimer lamps
… optical sources, with particular emphasis on excimer systems. In addition, microwave excitation of a gas laser is considered. A novel apparatus was designed and built to couple 2.45-GHz microwave radiation into a gas discharge. The microwave resonator is the essential part of this equipment, …
-
Investigations into the xenon chloride excimer laser
A discharge pumped LC inversion type XeCl excimer laser was constructed, and its discharge and output were examined. A maximum output energy of 167 mJ was achieved, with an efficiency of 0.56%, using 60 psi of a gas composed of 0.56% HCl, 2.48% Xe, 48.48% He, and 48.48% Ne. The 308 nm laser output …
-
Studies of tunable, high power excimer lasers
A detailed investigation of tunable, high power excimer lasers, particularly of the electron-beam pumped XeF(C $\to$ A) laser, is presented. A numerical model is described which simulates the performance of such lasers. The output energy and temporal profile of an injection controlled XeF(C $\to$ …
-
Neutron Detection by Noble Gas Excimer Scintillation
… that do not rely on <super>3</super>He. Excimer-based neutron detection (END) is a potential alternative with many advantages, notably the lack of dependence on <super>3</super>He. Similar to traditional proportional counters, END operates on the interaction of a neutron with a neutron …
-
Excimer Emission From Pulsed Microhollow Cathode Discharges
… MHCDs in xenon and argon have shown to emit excimer radiation at 172 and 127 nm, respectively. Internal efficiency of excimer emission in DC MHCD was measured to be 6–9% in xenon, and 1–6%, depending on the gas flow rate in argon. This high efficiency is due to the high rate of rare gas …
-
Modeling and Diagnosis of Excimer Laser Ablation
… multilayer substrate. A scanning projection excimer laser system has been utilized to fabricate the microvias. In this thesis, a novel technique implementing statistical experimental design and neural networks (NNs) is used to characterize and model the excimer laser ablation process for …
-
Corneal light scattering following excimer laser surgery
… the morphological changes in the cornea followingexcimer laser surgery.Methods Initially, the optical mechanisms of the image formation on the retina arediscussed. Following, the optical parameters of the corneal morphology are characterizedto form a theoretical model describing the forward light …
-
Optimization of ZeF(C-->A) excimer laser performance
… in the formation and removal of the diatomic excimer XeF(C). Significantly improved XeF(C-»A) laser performance has been achieved using e-beam excitation of a multi-component gas mixture that has permitted synthesis of near optimum medium properties for which XeF(C) is produced efficiently …
-
Compression of femtosecond krypton fluoride excimer laser pulses
Temporal characteristics of compressed femtosecond KrF pulses are measured with the help of a single-shot phase-sensitive autocorrelator for the UV. The performance of a prism compressor and the influence of higher order phase dispersion on the ultimate pulse width of compressed pulses is …
-
Amorphization of iron-boron alloys by excimer laser processing
… slightly overlapping single pulses from a XeCl excimer laser to study the extent to which amorphization occurs at extremely high heating and cooling rates. The influence of the initial microstructure and phases upon the structure that results after laser processing was also studied.</p> <p>A …
-
Studies in microwave and RF capacitively coupled excimer lamp
… in the plasmas generated by these two novel excimer lamps.;We designed, constructed and studied (1) a probe-coupled 2.45 GHz microwave arrangement to drive Xe and KrI excimer lamps and (2) a 13.45 GHz RF capacitively coupled arrangement to drive Xe/XeAr excimer lamps. In the 2.45 GHz …
Page 1 of 23