Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 12 of 12 for “"Excimer lamps"”.
-
Microhollow Cathode Discharge Excimer Lamps
… pressures favors three body processes such as excimer formation. This was confirmed by experiments in xenon and argon where emission of excimer radiation at 172 nm and 130 nm, respectively, was observed when the pressure was increased beyond 50 Torr. The intensity of excimer radiation in xenon …
-
Continuous microwave excitation of excimer lamps
… optical sources, with particular emphasis on excimer systems. In addition, microwave excitation of a gas laser is considered. A novel apparatus was designed and built to couple 2.45-GHz microwave radiation into a gas discharge. The microwave resonator is the essential part of this equipment, …
-
Excimer UV Radiation from a Cylindrical Dielectric Barrier Discharge
Excimer lamps are intense non-coherent radiation sources, which emit UV or VUV radiation in a narrow wavelength range. The operation of these excimer lamps depends on the decomposition of excimers that are created in various non-equilibrium discharge plasmas. Excimer lamps mainly use rare gases or …
-
Studies in microwave and RF capacitively coupled excimer lamp
… in the plasmas generated by these two novel excimer lamps.;We designed, constructed and studied (1) a probe-coupled 2.45 GHz microwave arrangement to drive Xe and KrI excimer lamps and (2) a 13.45 GHz RF capacitively coupled arrangement to drive Xe/XeAr excimer lamps. In the 2.45 GHz …
-
Enhancing the Destruction of Per- and Polyfluoroalkyl Substances in Aqueous Film-forming Foam with 222 NM UV-Photoreductive Technology
… thesis explores applying krypton chloride (KrCl) excimer lamps at 222 nm to enhance UV-ARP's ability to degrade PFAS. UV_222-ARP was applied to two treatment-relevant dilutions of PFOS-based AFFF, and fluoride release was measured over 24 hours. Comparative analysis of UV_222/sulfite and …
-
Enhancing the Destruction of Per- and Polyfluoroalkyl Substances in Aqueous Film-forming Foam with 222 NM UV-Photoreductive Technology
… thesis explores applying krypton chloride (KrCl) excimer lamps at 222 nm to enhance UV-ARP's ability to degrade PFAS. UV_222-ARP was applied to two treatment-relevant dilutions of PFOS-based AFFF, and fluoride release was measured over 24 hours. Comparative analysis of UV_222/sulfite and …
-
Enhancing the Destruction of Per- and Polyfluoroalkyl Substances in Aqueous Film-forming Foam with 222 NM UV-Photoreductive Technology
… thesis explores applying krypton chloride (KrCl) excimer lamps at 222 nm to enhance UV-ARP's ability to degrade PFAS. UV_222-ARP was applied to two treatment-relevant dilutions of PFOS-based AFFF, and fluoride release was measured over 24 hours. Comparative analysis of UV_222/sulfite and …
-
Enhancing the Destruction of Per- and Polyfluoroalkyl Substances in Aqueous Film-forming Foam with 222 NM UV-Photoreductive Technology
… thesis explores applying krypton chloride (KrCl) excimer lamps at 222 nm to enhance UV-ARP's ability to degrade PFAS. UV_222-ARP was applied to two treatment-relevant dilutions of PFOS-based AFFF, and fluoride release was measured over 24 hours. Comparative analysis of UV_222/sulfite and …
-
Impacts of Natural Organic Matter on Perchlorate Removal by an Advanced Reduction Process
… light produced by low-pressure mercury lamps or KrCl excimer lamps. The results indicate that NOM strongly inhibits perchlorate removal by either the sulfite/UV-KrCl or the sulfite/UV-L ARP, because NOM competes with sulfite for UV light and can possibly scavenge sulfite radicals. Even …
-
UV-Sulfite Based Advanced Reduction Treatment of Disinfection Byproducts and Perfluorooctanoic Acid
… of UV/SO3^2- ARP was tested under UV-L and excimer lamps. Quantum yields for the process were calculated to be in the range of 0.002 to 0.004 mol/Ein. Presence of radical scavengers such as alkalinity lowered the kinetics and quantum yields for the process. Excimer lamp offered improvement …
-
Mitigation of airborne PRRSV transmission with UV light treatment: Proof-of-concept
… aerosolized PRRSV, specifically, four UV lamps, UV-A (365 nm, both fluorescent and LED-based), "excimer" UV-C (222 nm), and germicidal UV-C (254 nm), were tested for this purpose. The two UV-C lamps effectively irradiated fast-moving PRRSV aerosols with short treatment times (<2 s), …
-
NONTHERMAL AND PHYSICOCHEMICAL APPROACHES FOR COMBATING PATHOGENIC BACTERIA IN FOOD PROCESSING AND HANDLING, AND HEALTHCARE ENVIRONMENTS
… However, conventional ultraviolet (UV) mercury lamps have limitations including inactivation variability, low energy efficiency, and detrimental effects on mammalian cells. Chapter One to Three in this thesis present a quantitative assessment of the potential of various light-based technologies, …