Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 51 for “"Exposure system"”.
-
Inhalation exposure system for diesel exhaust particulates
… particulate (DEP) needed for animal inhalation exposures. Second, instrumentation was evaluated for aerosolizing DEP, monitoring the mass concentration and size distribution, and determining the uniformity of the aerosol.;The Jet-O-Mizer jet mill produced a single mode DEP mass median diameter …
-
Validation of Nanosecond Pulse Cancellation Using a Quadrupole Exposure System
… bioeffects be exploited in a complex electrode exposure system to spatially modulate cell permeabilization? This dissertation presents a systematic study of an efficient coplanar quadrupole electrode nsPEF delivery system that exploits unique differences between unipolar and bipolar nsPEF …
-
Biomimetic Aerosol Exposure System for in vitro Human Airway Exposure Studies
… their health effects. Current in vitro emissions systems, also called smoking robots, lack biomimicry, use unrealistic flow conditions, produce unrealistic aerosol dose, and provide inaccurate bio-mechanical cues to cell cultures, limiting ability to correlate in vitro outcomes with in vivo health …
-
A far-field radio frequency experimental exposure system for yeast: creating a new standard
… the potential effects of radiofrequency (RF) exposure on gene expression and cellular processes. Utilizing Schizosaccharomyces Pombe (S. pombe) as a model organism and specialized equipment to create a standard test environment for continued research in this field. Key methods include …
-
A Far-Field Radio Frequency Experimental Exposure System and 31 Day Exposure Experiment on Understanding Mice
… This thesis describes a new far field RF exposure system for unrestrained murine models that reduces experimental error and a 31 day experiment using mice in vivo. The experiment uses whole body exposure to continuous RF energy at 2.45 GHz on unrestrained, in vivo mice. Using RNA-seq to …
-
Dosimetric Characterization of a Waveguide-Based Exposure System for Laboratory Studies with Unrestrained Mice at 1.9 GHZ
… energy to be conducted using well-characterized exposure systems in order to ensure the reliability of research outcomes. Realizing this importance, a waveguide-based in vivo exposure system was developed at the Consumer and Clinical Radiation Protection Bureau of Health Canada for conducting …
-
Optimization of the VITROCELL® Exposure System for In Vitro Toxicity Testing of Diesel Emissions at the Air-Liquid Interface
… traditional methods, air-liquid interface (ALI) exposures constitute a superior in vitro model for assessing the toxicological activity of complex aerosols. By removing the medium barrier, aerosols can be delivered to the cells at their apical surface. This project investigated the utility of the …
-
Direct cigarette smoke exposure to 3D epithelial cell cultures by an aerosol exposure system - Development and evaluation of an in vitro model for COPD with direct cigarette smoke exposure on small airway epithelial cells in the air-liquid interface by the Vitrocell smoking system
… causes of deaths worldwide. Cigarette smoke exposure is one of the major risk factors for developing COPD. Up to 40% of smokers develop COPD over time, and continuous smoking drives the development and progression of the disease. The aim of this project was to develop and evaluate an in vitro …
-
An integrative approach for understanding the adverse outcome pathways in algae
… design and a suitable physical algal exposure system tailored towards hypothesis of acute chemical mode of action (MoA) and key events in adverse outcome pathways (AOPs) driven by time-resolved multi-omics profiling of algae. An experimental design aligned with the AOP framework was …
-
Investigate Woodsmoke and Interventions in an Exposure Chamber: A Tent Project
… not reached a consensus due to variations in exposure scenarios and health outcome measurements. Additionally, researchers have not tested the wildfire smoke PM intervention strategies, especially HEPA (high-efficiency particulate air)-filter portable air cleaners (PACs) and HEPA-installed …
-
Subnanosecond Exposure Systems for Biological Studies
… study of subnanosecond pulse effects calls for exposure systems for both cells and tissues. Two systems were designed in the scope of this thesis, used for cells and tissues respectively. The exposure system designed for cell exposure is a cuvette consisting of two parallel aluminum gaps. This …
-
Developing and validating a novel in vitro smoke exposure model and investigating the innate immunological impact of cannabis smoke exposure on primary human bronchial epithelial cells
… that are amenable to study whole cannabis smoke exposure are needed for immunological and toxicological studies that inform public health policy as well as medicinal and recreational cannabis use. In the present study, we developed and validated a novel three-dimensional (3D)-printed in vitro …
-
5 ns Electric pulses evoke longer-lived calcium responses in adrenal chromaffin cells than the physiological stimulus: an experimental and computational study
… the electric field distribution between the two exposure systems used in our laboratory that could explain why calcium responses evoked by a 5 ns pulse varied in duration with each exposure system. Experiments by our group were initially conducted with a gold strip electrode exposure system where …
-
Manufacturing immersion gratings, evolving circumstellar disks, and the archive in-between
… a highly uniform UV light source we call the UV Exposure System. In Chapter 1, I discuss the design and testing of an improved high uniformity UV Exposure system, which reaches 6.25% non-uniformity over a 130 mm diameter while preserving a high-intensity power throughput. The Immersion GRating …
-
The effects of ultrasound on endothelial cell behaviour and angiogenesis
… healing. The biological effects of ultrasound exposure have been reported in vitro and in vivo and represents a developing field of research. However, the effects of low frequency kHz ultrasound on cells remains under-researched. The aim of the present work was to study the effects of low …
-
Electromagnetic Analysis of Exposure Systems - Potential Factors Underlying the Variation in Duration of Nanosecond Electric Pulse-Evoked Changes in Intracellular Calcium Level in Adrenal Chromaffin Cells
… pulse. In our research, the first NEP delivery system that was used consisted of a gold strip chamber. Cells exposed to a 5 ns, 5 MV/m pulse with this exposure system resulted in short-lived (< 10 s) Ca2+ responses, similar to that evoked by physiological stimulus (5 - 6 s). However, when …
-
Characterizing exposure conditions for a quantum dot exposure chamber
… imperative. This project deals with inhalation exposures, culminating in an apparatus that generates a Qdot-containing test atmosphere in a small chamber. By putting test organisms in this chamber, the extent of toxicological and biotransformational effects can be measured. The main purpose of …
-
Biomonitoring of exposure to air pollutants: early biomarkers of exposure and effect
… have a relevant contribution towards the total exposure to pollutants. The biomarkers of exposure and effect were analysed in general population, to evaluate the impact of VOCs, PAHs and tobacco smoke exposure in everyday life. We designed a model for toxicological studies, as proof of concept …
-
Biological effects of low frequency ultrasound on bone and tooth cells
… DuoSon (SRA developments) therapeutic ultrasound exposure system, which allowed the comparison of kHz, MHz and a combined frequency ultrasound. Odontoblast-like cells positively responded to all ultrasound frequencies applied and can increase VEGF expression, increase cell number and increase …
Page 1 of 3