Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 9 of 9 for “"Extended Phase Graph"”
-
A GPU-accelerated MRI sequence simulator for differentiable optimization and learning
The Extended Phase Graph (EPG) Algorithm is a powerful tool for magnetic resonance imaging (MRI) sequence simulation and quantitative fitting, but simulators based on EPG are mostly written to run on CPU only and (with some exception) are poorly parallelized. A parallelized simulator compatible …
-
Diets in England: change, continuity and regionality between the Iron Age and Domesday Book (700 B.C -1086 A.D.)
… more accurately model the signal, we utilize the extended phase graph (EPG) model and derive voxel-wise maps of B1, T2 and S0 simultaneously. We show that EPG fitting provides improved T2 mapping under inhomogeneous B1 field. A second issue for quantitative T2 mapping in post-mortem brains is the …
-
Quantitative T2 imaging of whole post-mortem brains in ALS
… more accurately model the signal, we utilize the extended phase graph (EPG) model and derive voxel-wise maps of B1, T2 and S0 simultaneously. We show that EPG fitting provides improved T2 mapping under inhomogeneous B1 field. A second issue for quantitative T2 mapping in post-mortem brains is the …
-
Relaxometry in the Human Brain Using High Field Magnetic Resonance Imaging
… spin echo sequence by either Bloch equations or Extended Phase Graph (EPG) allows for indirect and stimulated echo compensation (ISEC). In this work, it is demonstrated that EPG-ISEC and Bloch-ISEC yield very similar but systematically different T2 results. EPG fitting provides reasonably …
-
Multi-component MRI transverse-relaxation parameter estimation to detect and monitor neuromuscular disease
… A multi-component slice-profile-compensated extended phase graph (sEPG) model for multi-echo Carr-Purcell-Meiboom-Gill (CPMG) spin-echo sequence signals was implemented, modelling the fat signal as two empirically calibrated sEPG components with fixed parameters, and the remaining unknown …
-
Novel Methods for T2 Estimation Using Highly Undersampled Radial MRI Data
… introduced. Indirect echo correction using the extended phase graph approach is then studied for standard sampled data. A novel reconstruction algorithm (SERENADE) is presented for the reconstruction of decay curves with indirect echoes from highly undersampled data. The technique is evaluated …
-
Simultaneous Whole-Heart Anatomical Imaging and Myocardial Tissue Characterization
… This general framework was implemented and extended for four different applications. First, an acquisition scheme that permitted the acquisition of 3D co-registered bright-blood and black-blood images was developed and validated in healthy subject. In the second application both the …
-
B1+-mapping and B1+ inhomogeneity correction at high field
Magnetic resonance images acquired at the highest strength of the main magnetic field B0 are of interest since they highly benefit from an increased signal to noise ratio. At ultra high field strengths (B0 > 7 Tesla) images with more contrast and higher resolution can thus be obtained, opening new …
-
Advances in Fast MRI Experiments
… methods such as X-rays and Computer To- mography. One major drawback of MRI, however, are long acquisition times and associated high costs of experiments. Since the introduction of MRI, several important technical developments have been made to successfully reduce acquisition times. In this …