Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 114 for “"External beam radiation therapy"”

  1. In Vivo Dosimetry Using Plastic Scintillation Detectors For External Beam Radiation Therapy

    … measurement of dose delivered to patients during radiation therapy, has significant potential in ensuring safe and effective treatment in radiation therapy. It can serve as point-of-delivery, patient specific quality assurance and direct verification of treatment. Despite evidence that <em>in …

    uthsc Repository record for In Vivo Dosimetry Using Plastic Scintillation Detectors For External Beam Radiation Therapy (opens in a new tab)

  2. Towards personalized PTV margins for external beam radiation therapy of the prostate

    External Beam Radiation Therapy (EBRT) is a common treatment option for patients with prostate cancer. When treating the prostate with EBRT, a geometric volume (PTV margin) is added around the prostate to account for uncertainties in treatment planning and delivery. Current methods for estimating …

    uvic Repository record for Towards personalized PTV margins for external beam radiation therapy of the prostate (opens in a new tab)

  3. Feasibility Study of Intensity Modulation for Low Dose Rate External Beam Radiation Therapy

    Previous studies have shown that low dose rate radiation therapy has radiobiological advantages for normal tissue. External irradiation techniques have been developed which use static blocked fields to irradiate a target which give a uniform dose rate over the area of the field but are unable to …

    ohiolink Repository record for Feasibility Study of Intensity Modulation for Low Dose Rate External Beam Radiation Therapy (opens in a new tab)

  4. Development of Mailed Dosimetric Audit for External Beam Radiation Therapy Using Alanine Dosimeters

    … for the independent check of dose delivery in external beam radiation therapy in Canadian cancer centres. The service will use mailed alanine dosimeters, and therefore the main focus of the project was to develop a low dose, clinically applicable, alanine dosimetry protocol. Alanine dosimetry …

    carleton Repository record for Development of Mailed Dosimetric Audit for External Beam Radiation Therapy Using Alanine Dosimeters (opens in a new tab)

  5. Effects of Patient Communication on Bladder Filling for External Beam Radiation Therapy Prostate Cancer Treatments

    Purpose: To observe the effect of increased feedback and communication with prostate cancer patients on bladder volume at the time of treatment Methods:: This study has 36 total subjects;, 23 controls and 13 experimental participants. The controls were selected retrospectively from prostate cancer …

    ohiolink Repository record for Effects of Patient Communication on Bladder Filling for External Beam Radiation Therapy Prostate Cancer Treatments (opens in a new tab)

  6. The overall survival and local control benefit of external beam radiation therapy for selected cancers

    … benefits achievable with optimal access to radiotherapy in Australia are unknown. This information would be of use for planning, priority setting, and economic analysis. Methods: 5-year local control (LC) and 2-year and 5-year overall survival (OS) benefits were investigated for gynaecological, …

    unsw Repository record for The overall survival and local control benefit of external beam radiation therapy for selected cancers (opens in a new tab)

  7. Study of novel techniques for verification imaging and patient dose reconstruction in external beam radiation therapy

    … verification is an essential step of radiotherapy. The purpose of this thesis is to develop new methods to improve the verification of photon and electron beam radiotherapy treatments. This is achieved through developing and testing (1) a way to acquire portal images during electron beam …

    mcgill Repository record for Study of novel techniques for verification imaging and patient dose reconstruction in external beam radiation therapy (opens in a new tab)

  8. A biomechanical approach for real-time tracking of lung tumors during External Beam Radiation Therapy (EBRT)

    … of cancer related death in both men and women. Radiation therapy is widely used for lung cancer treatment. However, this method can be challenging due to respiratory motion. Motion modeling is a popular method for respiratory motion compensation, while biomechanics-based motion models are …

    uwo Repository record for A biomechanical approach for real-time tracking of lung tumors during External Beam Radiation Therapy (EBRT) (opens in a new tab)

  9. Application of Machine Learning in Prostate Cancer External Beam Radiation Therapy to Improve Biochemical Failure-Free Survival Prediction

    Curative external beam radiation therapy (EBRT) is a common treatment option for localized prostate cancer. The reported biochemical failure-free survival (BFFS) for prostate cancer patients post-EBRT varies significantly. The current, widely implemented clinical models that are used to predict …

    calgary Repository record for Application of Machine Learning in Prostate Cancer External Beam Radiation Therapy to Improve Biochemical Failure-Free Survival Prediction (opens in a new tab)

  10. Clinical implementation of MOSFETs for entrance dose in-vitro dosimetry with high energy photons for external beam radiation therapy

    In external beam radiotherapy quality assurance is carried out on the individual components of the treatment chain. The patient simulating device, planning system and linear accelerators are tested regularly according to set protocols developed by national and international organizations. Even …

    adelaide Repository record for Clinical implementation of MOSFETs for entrance dose in-vitro dosimetry with high energy photons for external beam radiation therapy (opens in a new tab)

  11. A quantitative method for reproducible ionization chamber alignment to a water surface for external beam radiation therapy depth dose measurements

    … (ICs) are the most commonly used detectors for radiation therapy dose measurements. Typical IC measurements use cylindrical ICs in a water phantom and therefore require initial IC alignment to the water surface. This alignment has long been ignored and only recently has a qualitative governing …

    vcu Repository record for A quantitative method for reproducible ionization chamber alignment to a water surface for external beam radiation therapy depth dose measurements (opens in a new tab)

  12. The Relationship Of Physical Activity And Perceived Fatigue In Men Receiving External Beam Radiation Therapy For Non-Metastatic Prostate Cancer

    … to be the most distressing side effect of radiation therapy (RT), negatively effecting physical function and quality of life (Minton et al., 2013). Finding measures to predict, treat and help prevent fatigue can improve long term outcomes in cancer treatment. The primary aim of this study …

    nodak Repository record for The Relationship Of Physical Activity And Perceived Fatigue In Men Receiving External Beam Radiation Therapy For Non-Metastatic Prostate Cancer (opens in a new tab)

  13. Relationship of Mitochondrial Enzymes to Fatigue Intensity and Health-Related Quality of Life in Men with Prostate Cancer Receiving External Beam Radiation Therapy

    … of life (HRQOL) before and at the completion of external beam radiation therapy (EBRT) in men with nonmetastatic prostate cancer (NM-PC). To achieve this aim a secondary analysis of a descriptive, longitudinal study was conducted (#10-NR-0128). Results: A total of n = 22 men with NM-PC were …

    vcu Repository record for Relationship of Mitochondrial Enzymes to Fatigue Intensity and Health-Related Quality of Life in Men with Prostate Cancer Receiving External Beam Radiation Therapy (opens in a new tab)

  14. Protecting the Pee-Pee: A Comparison of Robotic Assisted Laparoscopic Prostatectomy and External Beam Radiation Therapy for Urinary and Sexual Function in Men Treated for Prostate Cancer

    … Assisted Laparoscopic Prostatectomy (RALP) and External Beam Radiation Therapy (EBRT) are standard treatments for clinically localized prostate cancer, but both of these treatments have negative consequences for urinary and sexual function in patients PURPOSE: To compare changes in urinary and …

    oregon Repository record for Protecting the Pee-Pee: A Comparison of Robotic Assisted Laparoscopic Prostatectomy and External Beam Radiation Therapy for Urinary and Sexual Function in Men Treated for Prostate Cancer (opens in a new tab)

  15. Overall survival and biochemical failure-free survival comparison of brachytherapy treatment options versus external beam radiation therapy for both low and intermediate-risk prostate cancer: A propensity-score matched analysis

    … prostate cancer patients that received brachytherapy [low-dose-rate brachytherapy (LDR-BT) or high-dose-rate brachytherapy with external beam radiation therapy (HDR-BT+EBRT)] versus external beam radiation therapy (EBRT) alone. Materials/Methods: Patient data was obtained from the ProCaRS …

    uwo Repository record for Overall survival and biochemical failure-free survival comparison of brachytherapy treatment options versus external beam radiation therapy for both low and intermediate-risk prostate cancer: A propensity-score matched analysis (opens in a new tab)

  16. Prevention of Radiation-Induced Skin Reactions in Breast Cancer External Irradiation

    Radiation dermatitis is a common side effect of external beam radiation therapy. The purpose of this study was to evaluate the effectiveness of applying an aloe vera based skin gel to the target area skin in preventing the development of radiation dermatitis to postlumpectomy/ mastectomy patients …

    wku-diss Repository record for Prevention of Radiation-Induced Skin Reactions in Breast Cancer External Irradiation (opens in a new tab)

  17. Development of an Arduino-based 3D printed 6DOF robotic phantom and a MATLAB-based software for Radiation Therapy Quality Assurance

    … accelerators (linac) is the primary concern in external beam radiation therapy. In this research, we have developed a MATLAB-based software named Quality Assurance for Linacs (QALMA), which is unique, due to cost-effectiveness, user friendly interface, and customizability. It includes five …

    fau Repository record for Development of an Arduino-based 3D printed 6DOF robotic phantom and a MATLAB-based software for Radiation Therapy Quality Assurance (opens in a new tab)

Page 1 of 6