Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 19 of 19 for “"Eyelet"”

  1. Two Point Resolution of a Defocused Multi-Aperture System Eyelet

    … amounts of system redundancy. An individual eyelet of a multi-aperture system consists of a gradient index lens coupled to optical fibers which transfer the incident light on the lens to individual detectors. A mathematical model of an individual eyelet was developed. It is a flexible model …

    ucf Repository record for Two Point Resolution of a Defocused Multi-Aperture System Eyelet (opens in a new tab)

  2. Optimising nanopores for DNA sequencing: A computational perspective

    … dynamics and ability to allow DNA translocation. Eyelet loops forming the CsgG constriction were found to exhibit large variations in their mobility, with at least one loop moving upwards into the vestibule under an applied electric field. CsgF was found to stabilise CsgG and the eyelet loop …

    soton Repository record for Optimising nanopores for DNA sequencing: A computational perspective (opens in a new tab)

  3. Analysis of the light--entrainment pathways for the circadian clock of Drosophila melanogaster

    … by norpAP41); gl60j in addition removes the H-B eyelet and a subset of DNs (DN1s). The H-B eyelet projects axons toward the s-LNvs pacemaker neurons. Both in the s-LNvs and in the DN1s the molecular PER and TIM cyclings can still be synchronized by light in norpAP41;cryb double mutant flies. …

    regensburg-diss Repository record for Analysis of the light--entrainment pathways for the circadian clock of Drosophila melanogaster (opens in a new tab)

  4. Standardization of test methodology: a comparison between three suture anchors

    … determine whether suture anchor failure due to eyelet cut-out or suture wear-out resulting from the sharp edges of the eyelet is the major cause of failure of bone-suture anchor-bone complexes. Cyclic loading of suture anchors during testing for durability has not been used previously even …

    tamu Repository record for Standardization of test methodology: a comparison between three suture anchors (opens in a new tab)

  5. Force and centre of pressure measurements during ice hockey skating with a regular and a modfied ice hockey skate

    … modified skate with an altered tendon guard and eyelet configuration which allows for increased dorsiflexion and plantarflexion. The objective of this study was to determine if those skate design changes would result in biomechanical changes in the skaters during forward skating. Both left and …

    mcgill Repository record for Force and centre of pressure measurements during ice hockey skating with a regular and a modfied ice hockey skate (opens in a new tab)

  6. A comparison of the treating mandibular fractures at the department of maxillofacial and oral surgery, Groote Schuur hospital

    … This method entails the placement of eyelet wires between or around teeth in both arches and then placing the patient into intermaxillary fixation. This is the method of choice when treating an undisplaced fracture of the mandible.

    western-cape Repository record for A comparison of the treating mandibular fractures at the department of maxillofacial and oral surgery, Groote Schuur hospital (opens in a new tab)

  7. Šiaudų paruošimo įrenginys /

    … the desired power extraction, equipment lifting eyelet load allowed stress calculation). The third part analyzed three parts fabrication. Were selected blank parts, created technological routes, determinated equipment necessary for manufacturing operations, calculated it‘s amount. Determinated an …

    vilnius Repository record for Šiaudų paruošimo įrenginys / (opens in a new tab)

  8. Εμβιομηχανική της συρραφής και καθήλωσης του μυοτενόντιου πετάλου του ώμου: πειραματική μελέτη σε παρασκευάσματα προβάτου

    … ones and often in either of them the eyelet fails first. Metallic anchors mounted with modern non-absorbable sutures will fail last. The tendon-suture level using simple and mattress technique will fail first, however, it can be improved with MCT or MMA techniques.

    greece Repository record for Εμβιομηχανική της συρραφής και καθήλωσης του μυοτενόντιου πετάλου του ώμου: πειραματική μελέτη σε παρασκευάσματα προβάτου (opens in a new tab)

  9. Comparisons of player calibers and skate models during an ice hockey explosive transitional maneuver

    … modified skate with an altered tendon guard and eyelet configuration which allows for increased dorsiflexion and plantarflexion. The objective of this study was to describe the differences in skating mechanics and kinetics between high and low caliber skaters and between the two different skate …

    mcgill Repository record for Comparisons of player calibers and skate models during an ice hockey explosive transitional maneuver (opens in a new tab)

  10. Force measurement and ankle motion of the forward skating and crossovers with a standard hockey skate and a modified hockey skate

    … a second One95 with a modified tendon guard and eyelet configuration (DROM). The intent was to determine if mechanical differences exist in push-off force and ankle kinematics between the two skates. The right skate of each type was instrumented with a calibrated force transducer system to …

    mcgill Repository record for Force measurement and ankle motion of the forward skating and crossovers with a standard hockey skate and a modified hockey skate (opens in a new tab)

  11. Frontal Plane Humeral Elevation Effects on the Pullout Strength of Suture Anchors Used in Rotator Cuff Repair

    … prone to various types of failure such as anchor eyelet breakage, suture failure, and anchor pullout. These failure modes necessitate intervention to reattach the tendon thus prolonging the healing period. Identifying and minimizing these failure modes will ensure optimum healing. There are two …

    calpoly Repository record for Frontal Plane Humeral Elevation Effects on the Pullout Strength of Suture Anchors Used in Rotator Cuff Repair (opens in a new tab)

  12. Spacially Sampled Multi-Aperture Optical System for Robot Vision

    … no need for optical alignment. An individual eyelet of the vision system consists of a Gradient Index (GRIN) lens, and seven optical fibers which transfer the incident light on the lens to individual detectors. Each detector or pixel, integrates the intensity over the unique region that it …

    ucf Repository record for Spacially Sampled Multi-Aperture Optical System for Robot Vision (opens in a new tab)

  13. Development of Two Forecasting Systems and the Design of Hard Copy Information Displays

    … company of fastener manufacturers Geo. Tucker Eyelet Co. Ltd. Two main projects at the company are reported. The first being the forecasting of raw material requirements. The need for more accurate forecasting is examined together with the existing materials control systems and the Materials …

    aston Repository record for Development of Two Forecasting Systems and the Design of Hard Copy Information Displays (opens in a new tab)

  14. MECHANCIAL PROPERTIES OF ELASTIC THREAD FORCE SYSTEMS IN CANINE EXPOSURES AND APPLICATION OF FORCE

    … was tied to the fifth link opposite the bondable eyelet. The length of the elastic thread and the total apparatus was measured to the hundredth of a millimeter and recorded. An Instron with a ramp speed of 100 mm/min was used for all testing. Results: The addition of the gold chain, as compared to …

    temple Repository record for MECHANCIAL PROPERTIES OF ELASTIC THREAD FORCE SYSTEMS IN CANINE EXPOSURES AND APPLICATION OF FORCE (opens in a new tab)

  15. Experimental simulation of the natural shoulder joint

    … deltoid) using a modified finger trap suture. Eyelet screws were attached to the scapula to act as pulleys and maintain the line of action of the muscles. Forces applied by the stepper motors were measured using a custom load measurement platform and a compression load cell. The human shoulder …

    whiterose Repository record for Experimental simulation of the natural shoulder joint (opens in a new tab)

  16. Light entrainment of the circadian clock: the importance of the visual system for adjusting Drosophila melanogaster´s activity pattern

    … of the extraretinal Hofbauer-Buchner eyelet for clock synchronization. Excitation of the eyelet leads to Ca2+ and cAMP increases in specific clock neurons, consequently resulting in a shift of the flies´ rhythmic activity. Taken together, the experiments conducted in this thesis …

    wurz-thes Repository record for Light entrainment of the circadian clock: the importance of the visual system for adjusting Drosophila melanogaster´s activity pattern (opens in a new tab)

  17. Unusual eye design: The compound-lens eyes of Strepsiptera and the scanning eyes of Sunburst Diving Beetle larvae

    … of a smaller number of relatively large units (eyelets), each with an extended retina with often more than one hundred photoreceptors. In the strepsipteran species, Xenos peckii, each eye has about 50 eyelets. By using a behavioral paradigm based on the optomotor response, I have provided …

    ohiolink Repository record for Unusual eye design: The compound-lens eyes of Strepsiptera and the scanning eyes of Sunburst Diving Beetle larvae (opens in a new tab)

  18. The impact of thermogenetic depolarizations of specific clock neurons on Drosophila melanogaster's circadian clock

    … from the photoreceptive organs (Hofbauer-Buchner eyelet, photoreceptor cells of compound eyes, ocelli) or from other clock neurons, which might inhibit phase advances during the subjective day. To get an impression of the molecular state of the clock in the delay and advance zone, staining …

    wurz-thes Repository record for The impact of thermogenetic depolarizations of specific clock neurons on Drosophila melanogaster's circadian clock (opens in a new tab)

  19. Contribution des rhodopsines et des récepteurs à l’histamine dans la synchronisation de l’horloge circadienne par la système visuel chez Drosophila melanogaster

    … l'oeil composé, les ocelles et l'eyelet de Hofbauer-Buchner, qui expriment chacun une ou plusieurs rhodopsines. La cascade de phototransduction activée par la lumière dépend de la phospholipase C-ß NORPA et conduit à une libération d’histamine. Dans notre étude, nous avons tenté de …

    star-france Repository record for Contribution des rhodopsines et des récepteurs à l’histamine dans la synchronisation de l’horloge circadienne par la système visuel chez Drosophila melanogaster (opens in a new tab) Restricted access