Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 65 for “"FC-72"”
-
Pool boiling and spray cooling with FC-72
Doctor of Philosophy (Ph.D.)
-
Computer simulation of a spray cooling system with fc-72
Doctor of Philosophy (Ph.D.)
-
Fundamental Study Of Fc-72 Pool Boiling Surface Temperature Fluctuations And Bubble Behavior
A heater designed to monitor surface temperature fluctuations during pool boiling experiments while the bubbles were simultaneously being observed has been fabricated and tested. The heat source was a transparent indium tin oxide (ITO) layer commercially deposited on a fused quartz substrate. Four …
-
Heat transfer enhancement due to bubble pumping in FC-72 near the saturation temperature.
The use of boiling heat transfer in the liquid immersion cooling of electronic components has always been hampered by the excessive superheat necessary to initiate nucleation in the fluorinated hydrocarbons used as dielectric cooling fluids. In an attempt to overcome some of these difficulties, an …
-
The Effect of Variable Gravity on the Cooling Performance of a Partially-Confined FC-72 Spray
… chamber. The fluid used for this testing was FC-72, which is a non-toxic, non-flammable, and non-reactive refrigerant. Due to its dielectric nature, FC-72 was sprayed directly onto the electric thick film heaters. The parametric ranges of this experiment were as follows: Heat flux to the …
-
The Effect of Dissolved Air on the Cooling Performance of a Partially-Confined FC-72 Spray
… transfer performance of a partially-confined FC-72 spray with varying dissolved air concentrations. An experimental test rig consisting of a spray chamber coupled to a fluid delivery loop system was used to obtain temperature, pressure, and critical heat flux (CHF) data. A downward facing …
-
Pool boiling heat transfer from porous-coated surfaces in FC-72, the effects of subcooling and non-boiling immersion time
Thesis (M.S.)--Michigan State University. Department of Mechanical Engineering, 2005
-
Experimental investigations of temperature controlled innovative annular flow-boiling of FC-72 in millimeter scale ducts – steady and enhanced pulsatile realizations
… The experimental investigations (with FC-72 as a working fluid) were carried out within a horizontal test-section of 50 cm length and rectangular cross-section (depth = 15 mm and height = 2 mm). Temperature controlled heating (by using reversed and controllable thermo-electric coolers) …
-
Convection and Flow Boiling in Microgaps and Porous Foam Coolers
… model and, together with the convective FC-72 data, establish a baseline for microgap cooler performance. The two-phase heat transfer characteristics of FC-72 are examined at various microgap dimensions, heat fluxes, and mass fluxes and the results are projected onto a flow regime map. …
-
Effects of flow orientation on condensation in tubes
… characteristics of annular condensation of FC-72 in vertical downflow, vertical upflow and horizontal flow as well as the effects of channel orientation on flow condensation. Two separate condensation test modules are employed, one for high-speed video imaging of the film interface and the …
-
Enhancement of boiling heat transfer in di-electric fluids.
… components in flouorinated hydrocarbons (FC-72), is severely inhibited by the excessive amount of superheat required to initiate nucleate boiling. To conduct an experimental study of nucleate pool boiling of FC-72, an experimental test chamber was constructed. This chamber utilized five …
-
Heat Transfer in Boiling Dilute Emulsion with Strong Buoyancy
… Heat transfer experiments were carried out with FC-72 in water emulsions. FC-72 has a saturation temperature of 56 °C, far below that of water. The parameters were varied as follows: 0% ≤ ≤ 1% and 1.82 × 1012 ≤ RaH ≤ 4.42 × 1012. Surface temperatures along the heated surface reached temperature …
-
Direct liquid cooling of simulated electronic chips in a rectangular channel
… chips in a rectangular channel using water and FC-72. The experimental data of single-phase heat transfer cover the laminar flow and turbulent flow with Reynolds number based on chip length (Z,=10 mm)ranging from 6xl02 to 8xl04 for an inlet temperature of T^25°C. The effects of geometrical …
-
Flow Boiling of a Dilute Emulsion on a Microporous Surface
… 550 kg/m2s. The emulsions comprised droplets of FC-72 suspended in water at FC-72 volume fractions of 0.1, 0.5, 1 and 2%. Experiments were conducted for a smooth surface and three microporous surfaces of varying thickness (708, 633, 412 μm) and porosity (0.354, 0.410, 0.413). For water on the …
-
Flow Boiling of A Dilute Emulsion In the Transition Regime
… this study is an oil-in-water emulsions, where FC-72 is the oil whose droplets are suspended in water. The volume fractions for the emulsions are 1% and 2%. The heated test section is smooth. For single phase experiments, the heat transfer coefficient of water with increasing Reynolds number and …
-
SHEAR DRIVEN SUPPRESSED NUCLEATION ANNULAR FLOW-BOILING IN MILLIMETER-SCALE CHANNELS: DIRECT NUMERICAL SIMULATIONS
… detailed solutions for annular flow-boiling of FC-72 in a horizontal channel are presented.
-
Nucleate boiling heat transfer study of direct immersion cooling of a 3x3 array of vertically orientated electronic components in a dielectric fluid
… components in fluorinated hydrocarbons (FC-72), is severely inhibited by the excessive amount of superheat required to initiate nucleate boiling. This phenomenon is well documented. To experimentally study the effects of nucleate pool boiling, a test chamber was constructed. This chamber …
-
Analyses of steady and unsteady thermal behaviour of simulated electronic chips in a liquid cooled vertical rectangular channel
… a vertical rectangular channel using water and FC-72 as the working fluids. The steady-state experimental data covers a laminar flow regime with Reynolds number based on channel hydraulic diameter and Reynolds number based on heater length ranging from 0 to 2220 and 0 to 2775 respectively. The …
-
Effects of surface parameters on boiling heat transfer phenomena
… on pool boiling CHF of a well-wetting fluid, FC-72, was investigated. Nanoporosity or surface roughness alone had no effect on pool boiling CHF of FC-72. Data obtained in the literature mostly for microporous coatings showed CHF enhancement for well wetting fluids, and existing CHF models are …
-
Pool Boiling on Structured Surfaces: Heat Transfer and Critical Heat Flux : Experiments and Mechanistic Modelling
… structured surfaces with dielectric liquids (HFE-7200, NOVEC-649, FC-72), organic liquids (Acetone, Pentane) and deionized water.In the first step, nanoparticle coatings on copper surfaces were prepared by an electrophoretic deposition method, with Cu-Zn nanoparticles (100 nm) and Cu nanoparticles …
Page 1 of 4