Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 8 of 8 for “"FFF beam"”

  1. Determination of the Shape of a Flattening Filter Free (FFF) Radiation Beam When Modified by a Physical Wedge

    The determination of a flattening filter free (FFF) beam profile when the collimator is intentionally modified to incorporate a physical wedge. Specifically, radiation beam profiles change shape when a metallic wedge is placed in the path of the beam. Examination of this unknown is necessary to …

    ohiolink Repository record for Determination of the Shape of a Flattening Filter Free (FFF) Radiation Beam When Modified by a Physical Wedge (opens in a new tab)

  2. Unflattened Radiotherapy beams; characterisation, optimisation and application

    … was to investigate flattening filter free (FFF) beams produced by medical linear accelerators for radiotherapy applications, from their initial setup through to their clinical implementation. This was split into four sections that comprise the main experimental chapters of this thesis. The …

    whiterose Repository record for Unflattened Radiotherapy beams; characterisation, optimisation and application (opens in a new tab)

  3. Efficacy of the virtual cone method using fixed small multi-leaf collimator field for stereotactic radiosurgery

    … MLC field of 10 MV flattening filter-free (FFF) beam defined at 100 cm SAD, while jaws are positioned at 1.5 cm x 1.5 cm. A spherical dose distribution equivalent to 5 mm cone was generated by using 10–14 non-coplanar partial arcs. The dosimetric accuracy of this technique was validated …

    fau Repository record for Efficacy of the virtual cone method using fixed small multi-leaf collimator field for stereotactic radiosurgery (opens in a new tab)

  4. Improved Target Coverage of Spinal Metastases Through The Use of Flattening Filter Free Beams

    … recurrence at follow-up. Flattening Filter Free (FFF) photon beams have been shown to have lower out-of-field dose and sharper dose gradients when compared with conventionally flattened (FF) photon beams of similar energy; this sharp dose fall-off could potentially prove beneficial in cases where …

    uthsc Repository record for Improved Target Coverage of Spinal Metastases Through The Use of Flattening Filter Free Beams (opens in a new tab)

  5. Acquisition and Analysis of Megavoltage Linac Beam Transmission Data for Direct Verification of Photon Spectra Models in a Treatment Planning System

    … cone convolution algorithm, which relies on beam spectrum information for calculation of scatter contribution. Typically beam spectra are derived from a set of measurements collected during commissioning of a linear accelerator. The purpose of this project is to measure beam spectra …

    ohiolink Repository record for Acquisition and Analysis of Megavoltage Linac Beam Transmission Data for Direct Verification of Photon Spectra Models in a Treatment Planning System (opens in a new tab)

  6. IMRT and Rotational IMRT (mARC) Using Flat and Unflat Photon Beams

    … attening filters have been inserted into the beam path oflinacs to produce a uniform energy fluence distribution of the photon beam and make it suitable for clinical use. Recently, linacs without flattening fifilter (Flattening FilterFree - FFF) are increasingly used in radiotherapy because of …

    qucosa-diss Repository record for IMRT and Rotational IMRT (mARC) Using Flat and Unflat Photon Beams (opens in a new tab)

  7. Enhanced Optimization with VMAT Treatment Plan Delivered Using Varian TrueBeam System

    Purpose: To model the Varian TrueBeam linear accelerator (linac) in Monte Carlo dose calculation code, EGSnrc, using the phase space files provided by Varian. To broaden the applicability of Enhanced Optimization (EO) onto TrueBeam treatment plans (delivered with 6X/6X FFF beams, and HD MLCs), and …

    buffalo Repository record for Enhanced Optimization with VMAT Treatment Plan Delivered Using Varian TrueBeam System (opens in a new tab)

  8. Exploring RayStation Treatment Planning System: Commissioning Varian TrueBeam Photon and Electron Energies, and Feasibility of Using FFF Photon Beam to Deliver Conventional Flat Beam

    … process, an accurate model of the TrueBeam linear accelerator was made prior to clinical acceptances. Data collection, importing measurements, beam modeling, point dose verifications and clinical plan comparisons are procedures that must be done in order to complete the commissioning of …

    ohiolink Repository record for Exploring RayStation Treatment Planning System: Commissioning Varian TrueBeam Photon and Electron Energies, and Feasibility of Using FFF Photon Beam to Deliver Conventional Flat Beam (opens in a new tab)