Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 132 for “"FLIR"”.
-
Experimental FLIR study
A single cell, serially scanned, thermal imaging FLIR system has been constructed at NPS Monterey. The system consisted of a Cassegrain type reflecting telescope with a convergent beam, oscillating mirror scan system,and HgCdTe and InSb single cell infrared detectors. The system was first tested …
-
Monitorování prostředí pomocí miniaturní termokamery FLIR Lepton
… technickými specifikacemi a funkcemi senzoru Flir LEPTON 3.5, a vývojové platformy OpenMV Cam H7 R2. Druhá část práce poskytuje informace a instrukce ohledně práce se senzorem a ukazuje některé možné aplikace. Také jsou zde ukázané způsoby jak překonat některé limitace senzoru a porovnání s …
-
Study for the performance parameters of a FLIR system
… Difference for a Forward Looking Infra-Red (FLIR) system were measured after optimization of the system. The achieved performance approached the theoretically evaluated limiting values.
-
Comparison of FLIR Tactical Decision Aids for Inter-service use
… thesis presents a comparison between the Army FLIR TDA, (ACQUIRE), and the infrared module of the Navy/Air Force TDA, WinEOTDA. Differences in the modeling of underlying physical principles, input parameters, and predicted target detection ranges are presented. Despite differences in input and …
-
Modeled detection and recognition range for a polarization filtered FLIR sensor
… Diego bay in 1996. These scenarios represent a FLIR sensor on a platform in level flight at 100 m or 1000 m approaching a ship target, represented as a gray body at the recorded ship hot-spot temperature. The polarized version of the SEARAD sea radiance code was used to provide sea background …
-
Evaluation of effective MDTD/MRTD for FLIR from PREOS92 measurement data
… and compares ATapp with MDTD/MRTD of a typical FLIR system. The atmospheric propagation code (SEARAD) and Planck's radiation law were employed to obtain atmospheric transmittance and path radiance. The atmospheric parameters were selected as close to the aircraft overflights as possible using …
-
The design of a FLIR sensor for the Korean Army RPV.
This thesis considers a forward looking infrared (FLIR) sensor system fot the Korean Army mounted in a remotely piloted vehicle such as the Pioneer RPV. Potential missions considered for this system included tactical reconnaissance, surveillance and intelligence gathering, target acquisition and …
-
Target identification algorithm for the AN/AAS-44V Forward Looking Infrared (FLIR)
… In particular, we use infrared images from FLIR video taken at sea, and obtain classification results for a small test set. We tested eighteen images with success rates varying between seventy-three and eighty-nine percent
-
Estimate of maximum detection range for FLIR from EOMET 95 measurement data
FLIR sensor maximum range predictions for operational use may be based on the intersection of apparent target contrast temperature difference (deltaT sub app) and sensor minimum resolvable (MRTD) or minimum detectable temperature difference (MDTD), each expressed as a function of range. Ranges …
-
Modeling second generation FLIR sensor detection recognition and identification range with polarization filtering
… ranges of a generic second generation FLIR sensor is examined with a computational model. The scenario studied represents a second generation FLIR sensor mounted on an aircraft in level flight at 3OOm approaching a ship target. The target ship radiant signature is modeled with an …
-
Analysis of the effects of dynamic characteristic dimension calculations on FLIR performance prediction models.
… ability to accurately predict the performance of FLIR systems has become critical to today's military. The current U.S. defense industry standard FLIR analysis model is FLIR92 by the U.S. Army's C2NVEO. The algorithm in FLIR92 for calculating target acquisition probabilities, called ACQUIRE, has …
-
The effect of random variations of radiosonde data on the predicted FLIR performance calculated by the program UFLR.
… and 10,000 ft.. It was also determined that the FLIR performance may be degraded up to 10 nautical miles for a height level of 5,000 ft., and up 12 nautical miles for a height level of 10,000 ft. due to the random atmospheric variations.
-
HH-60H Armed Helicopter Subsystem operator workload assessment
… of all the Forward Looking Infrared (FLIR) and AGM-114 Hellfire Missile launch and designation modes in mission representative flight profiles. Both ground and flight tests were conducted to verify specification and test and evaluation master plan compliance and mission suitability for …
-
Beauty and the heat : exploring transit user thermal perception beyond the surface
… (TS) measured via Forward-Looking Infrared (FLIR) imaging with Landsat 8 satellite-derived temperatures. Findings indicate that Landsat 8 measures TS 10.7 degrees Celsius higher on average than the FLIR, while FLIR offers finer-resolution data more closely aligned with thermal comfort indices …
-
Applying unmanned aerial systems (UAS) and thermal infrared technology for the detection and surveying of wild ungulates
… UAS paired with Forward Looking Infrared (FLIR) technology to survey forest-dwelling species has been particularly challenging because of unreliable animal detection. There is also little understood about how the novel technology of UAS compares to conventional methodologies for surveying …
-
Infrared thermography of Erinaceus europaeus: Applications with hypothermia and hibernation.
… a result of shock, three infrared camera models (FLIR E60bx, FLIR C2 and FLIR One) were tested at Prickles and Paws Hedgehog Rescue Centre, Cubert, Cornwall. Surface eye temperature was used as a proxy for core temperature. The FLIR E60bx demonstrated increased accuracy when compared to rescue …
-
Targeting and fire control system analysis of the New Turkish Attack Helicopter "The AH-1Z Kingcobra"
… Martin's 3-5 micrometers midwave staring array FLIR. On the other hand, the Turkish Secretariat for Defense Industries (SSM) has chosen Aselsan ASELFLIR-300T that contains an 8-12 micrometers longwave scanning second-generation FLIR. A comparison of range performance for these two systems has …
Page 1 of 7