Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 10 of 10 for “"FPIA"”

  1. Validation of Floc Size Measurements Made with Flow Particle Image Analyzer (FPIA)

    … suspensions. The Flow Particle Image Analyzer (FPIA) is an image analysis based instrument used for particle size measurement. In this study, floc size measurements are made for suspensions of kaolinite in water. Size analysis results are additionally obtained using the Malvern Mastersizer and …

    alberta Repository record for Validation of Floc Size Measurements Made with Flow Particle Image Analyzer (FPIA) (opens in a new tab)

  2. Development of a sensitive, quantitative high-performance liquid chromatographic assay for the measurement of digoxin in patient groups with high levels of digoxin-like immunoreactive substances

    … (RIA) and fluorescence polarization immunoassay (FPIA) procedures, are used in the clinical laboratory because of their speed, precision, sensitivity and relatively low cost. However, reaction of the digoxin antibodies used in the immunoassay methods with digoxin metabolites, endogenous compounds …

    ubc Repository record for Development of a sensitive, quantitative high-performance liquid chromatographic assay for the measurement of digoxin in patient groups with high levels of digoxin-like immunoreactive substances (opens in a new tab)

  3. Analyse der Wirkstoffkonzentration von Paracetamol in Serum und Speichel nach rektaler Applikation bei gynäkologischen Eingriffen - Vergleichende Bestimmung der Paracetamol-Konzentrationen mittels HPLC und Immunoassay

    … und Fluoreszenz-Polarisations-Immunoassay (FPIA) bestimmt. Wir untersuchten 38 Patientinnen, die sich kleineren gynäkologischen Eingriffen unterzogen. Die Frauen erhielten 30 oder 40 mg/kg Paracetamol rektal verabreicht. Dann wurden 1, 2, 3, 4, 6, 8 und 12 Stunden nach Applikation simultan …

    fu-berlin Repository record for Analyse der Wirkstoffkonzentration von Paracetamol in Serum und Speichel nach rektaler Applikation bei gynäkologischen Eingriffen - Vergleichende Bestimmung der Paracetamol-Konzentrationen mittels HPLC und Immunoassay (opens in a new tab)

  4. Papain: a Novel Urine Adulterant.

    … such as the Fluorescence Polarized Immunoassay (FPIA) technique. Typical chemical adulterants such as nitrites are easily detected or render the urine specimen invalid as defined in the proposed federal guidelines for specimen validity testing based on creatinine, specific gravity and pH. Papain …

    etsu Repository record for Papain: a Novel Urine Adulterant. (opens in a new tab)

  5. Microdevice-integrated immunoassays for Point-of-Care Therapeutic Drug Monitoring

    … fluorescence polarization immunoassays (FPIA). The main feature offered by the FP assay format was the ability to perform homogeneous measurements with no separation or washing steps required. An important result of this thesis is the demonstration that the concentration of small drugs …

    epfl Repository record for Microdevice-integrated immunoassays for Point-of-Care Therapeutic Drug Monitoring (opens in a new tab)

  6. The Effect of Fine Flocculating Particles and Fine Inerts on Carrier Fluid Viscosity

    … optical-based particle size analysis technique (FPIA) was commissioned to study flocculating and inert fines and estimate volume fraction of aggregates. Experimental data suggest that viscosity correlations are improved significantly if the volume fraction of aggregates is used as the primary …

    alberta Repository record for The Effect of Fine Flocculating Particles and Fine Inerts on Carrier Fluid Viscosity (opens in a new tab)

  7. Effect of Sonication on the Particle Size of Kaolinite Clays

    … out using a Flow Particle Image Analyzer (Sysmex FPIA-3000). This study demonstrates that sonication results in a reduction of the number of large particles and also an increase in the proportion of the smallest particles. Results of experiments conducted on slurries having different pH, …

    alberta Repository record for Effect of Sonication on the Particle Size of Kaolinite Clays (opens in a new tab)

  8. Study of the opto-mechanical stability and optical performance for the future ELT-class telescope instrumentations.

    … the synergy between Focal Plane Image Analysis (FPIA) and the laser-based Telescope Metrology System (TMS). I contributed to the TMS integration with Adaptive Secondary Mirrors and optimized Collimation Look-Up Tables (CLUTs) to ensure stability across the full elevation range. Regarding the …

    bologna

  9. The pharmacokinetic interaction between cyclosporine and methoxsalen

    … using a fluorescence polarisation immunoassay (FPIA) technique. There was a statistical significant difference in AUCo-00 and Cmax ' for cyclosporine when methoxsalen was added to the drug regimen. When the methoxsalen levels were compared with those in the presence of cyclosporine, the levels …

    nwu-za Repository record for The pharmacokinetic interaction between cyclosporine and methoxsalen (opens in a new tab)

  10. Influência da função renal na otimização da terapêutica da amicacina

    … de imunoensaio de polarização fluorescente (FPIA). A determinação dos parâmetros farmacocinéticos da amostra foi realizada recorrendo ao programa informático PKS e às equações Sawchuk e Zaske, tendo sido admitidas 793 concentrações séricas, obtidas em pleno estado de equilíbrio estacionário …

    coimbro Repository record for Influência da função renal na otimização da terapêutica da amicacina (opens in a new tab)