Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 22 for “"FRP tube"”

  1. RETROFIT OF STRUCTURAL STEEL COLUMNS USING FRP-CONCRETE COMPOSITE SYSTEMS

    <p>Fiber reinforced polymer (FRP) - confined concrete-steel composite columns have been recently introduced as a retrofit technique for structural steel columns. This technique involves placing an FRP tube around an in situ steel column and subsequently filling the void between the steel section …

    mcmaster Repository record for RETROFIT OF STRUCTURAL STEEL COLUMNS USING FRP-CONCRETE COMPOSITE SYSTEMS (opens in a new tab)

  2. Mechanical Behavior of Hybrid Concrete-Filled Fiber Reinforced Polymer Tube Columns

    … the concrete-filled fiber reinforced polymer (FRP) tube (CFFT) system has been extensively studied the past few decades as an alternative design for bridge columns. This column system greatly simplifies construction by eliminating the need for column formwork and associated scaffolding. It also …

    uconn-diss Repository record for Mechanical Behavior of Hybrid Concrete-Filled Fiber Reinforced Polymer Tube Columns (opens in a new tab)

  3. Behavior of hollow-core fiber reinforced polymer-concrete-steel bridge columns under extreme loading

    … between an outer fiber reinforced polymer (FRP) tube and an inner steel tube. The steel tube was embedded into a reinforced concrete footing with an embedded length of 1.6-1.8 times the diameter of the steel tube. The FRP tube only confined the concrete wall and truncated at the top of the …

    must-thes Repository record for Behavior of hollow-core fiber reinforced polymer-concrete-steel bridge columns under extreme loading (opens in a new tab)

  4. Flexural Behavior of Composite FRP-Concrete-Steel Poles

    … consists of an outer fiber reinforced polymer (FRP) shell, inside steel tube, and concrete filled between the two tubes (The composite FRP-concrete-steel pole is hereafter referred to as CFCSP). The FRP tube used in this research is produced using a centrifugal casting technique with …

    uab Repository record for Flexural Behavior of Composite FRP-Concrete-Steel Poles (opens in a new tab)

  5. FRP-concrete-steel composite structural members

    The use of fibre reinforced polymer (FRP) composites as a confinement material for concrete has received a great deal of attention over the past two decades. Together with the retrofitting applications, the use of FRP as confinement material in the construction of new high-performance composite …

    adelaide Repository record for FRP-concrete-steel composite structural members (opens in a new tab)

  6. Static and Fatigue Behaviour of Hybrid Precast Concrete Truss Bridge Girders with Connections Reinforced with Single-Headed Bars

    … of both fibre reinforced polymers (FRPs) and concrete combined in a hybrid form for construction of light and durable bridge structures. The composite bridge system comprises transversely spaced precast prestressed truss girders and a cast-in-place or precast concrete deck connected …

    calgary Repository record for Static and Fatigue Behaviour of Hybrid Precast Concrete Truss Bridge Girders with Connections Reinforced with Single-Headed Bars (opens in a new tab)

  7. Long-term behavior of fiber reinforced polymer (FRP) confined concrete cylinders subjected to severe weather and seawater solution conditions

    … on durability of fiber-reinforced polymer (FRP) confined concrete cylinders subjected to various environmental conditions. Two types of cylinders were tested in this experiment: concrete-filled FRP tube (CFFT) and hollow-core FRP-concrete-steel (HC-FCS), with FRP tubes having two different …

    must-thes Repository record for Long-term behavior of fiber reinforced polymer (FRP) confined concrete cylinders subjected to severe weather and seawater solution conditions (opens in a new tab)

  8. Performance evaluation of fibreglass reinforced polymer resins in hydrometallurgical process solutions

    Fibre reinforced plastic (FRP) tanks and pipes exposed to corrosive environment in hydrometallurgical process plants are expected to degrade. The objective of this research is to develop a series of tests which are sensitive to the exposure and will be able to distinguish different materials used …

    newfoundland Repository record for Performance evaluation of fibreglass reinforced polymer resins in hydrometallurgical process solutions (opens in a new tab)

  9. Flexural behaviour of spun-cast concrete-filled fibre reinforced polymer tubes for pole applications

    … with structural Fibre-Reinforced Polymer (FRP) tubes and eliminating steel reinforcement is explored for the first time. This would make spun-cast FRP tubes (SCFTs) desirable in pole applications, as they are relatively light-weight, protected from deicing salts and other elements by the …

    queens Repository record for Flexural behaviour of spun-cast concrete-filled fibre reinforced polymer tubes for pole applications (opens in a new tab)

  10. Development of an Ultra-Lightweight Buckling-Restrained Brace Using Analytical and Numerical Methods

    … using a highly ductile aluminum core and FRP restrainer. Utilization of lightweight materials results in a BRB that is 25% the weight of traditional mortar-filled tube varieties allowing easy installation in small to medium sized buildings requiring seismic retrofit without the need for …

    portland-state Repository record for Development of an Ultra-Lightweight Buckling-Restrained Brace Using Analytical and Numerical Methods (opens in a new tab)

  11. Torsion and Combined Loading of Concrete-Filled Fibre-Reinforced Polymer Tubes

    The concrete-filled fibre-reinforced polymer tube (CFFT) is a unique structural system well suited for applications in harsh environments. The loading response of CFFTs has been widely studied; however, their torsional behaviour has not been evaluated. This thesis presents a study on CFFT response …

    queens Repository record for Torsion and Combined Loading of Concrete-Filled Fibre-Reinforced Polymer Tubes (opens in a new tab)

  12. Moment Connections of Concrete-Filled Fibre Reinforced Polymer Tubes to Reinforced Concrete Footings

    Fiber reinforced polymers (FRPs) are increasingly being accepted in structural engineering applications. One promising system involves the use of concrete-filled FRP tubes (CFFTs) as bridge piers, columns or piles. While CFFT members have been extensively studied under various loading conditions, …

    queens Repository record for Moment Connections of Concrete-Filled Fibre Reinforced Polymer Tubes to Reinforced Concrete Footings (opens in a new tab)

  13. Flexural Performance and Moment Connections of Concrete-Filled GFRP Tubes (CFFTs) and CFFT-encased Steel I-Sections

    … addresses a new hybrid system, concrete-filled FRP tube (CFFT)-encased steel I-sections. The embedded steel section enhances flexural strength, stiffness and ductility, and facilitates connection of the CFFT member to footings or other members. Phase I addresses the flexural behaviour of the …

    queens Repository record for Flexural Performance and Moment Connections of Concrete-Filled GFRP Tubes (CFFTs) and CFFT-encased Steel I-Sections (opens in a new tab)

  14. Design and characterization of natural flax fibre reinforced polymer tube encased coir fibre reinforced concrete composite structure

    … materials in fibre reinforced polymer (FRP) composites. The use of natural fibres, i.e. coir, as reinforcement within concrete structures will help to achieve a sustainable consumption pattern of building materials. Based on this fact, steelfree concrete structure using natural fibre …

    auckland-ms Repository record for Design and characterization of natural flax fibre reinforced polymer tube encased coir fibre reinforced concrete composite structure (opens in a new tab)

  15. Axial compressive behavior of FRP-concrete-steel double-skin tubular columns

    … structural system has been proposed in terms of FRP-concrete-steel double-skin tubular columns (DSTCs). This composite system consists of a steel tube inside, an FRP tube outside with concrete in between, and it combines the advantages of all three materials to achieve a high-performance …

    adelaide Repository record for Axial compressive behavior of FRP-concrete-steel double-skin tubular columns (opens in a new tab)

  16. Investigations of Ultra-High Performance Fibre Reinforced Concrete (UHPFRC) Column

    … performances of the concrete-filled carbon FRP tube (CFRP-CFFT) columns manufactured with ultra-high-performance fibre reinforced concrete (UHPFRC). Furthermore, finite element (FE) analysis incorporating CDP and Hashin’s damage model is then conducted to simulate both the structural …

    adelaide Repository record for Investigations of Ultra-High Performance Fibre Reinforced Concrete (UHPFRC) Column (opens in a new tab)

  17. Experimental and Analytical Seismic Studies of a Four-Span Bridge System with Composite Piers

    … model was supported on fiber-reinforced polymer (FRP) composite piers implementing accelerated bridge construction (ABC) techniques. The bridge was a quarter scale model of a 4-span bridge with continuous reinforced concrete superstructure and a drop cap, two-column pier design. Each pier utilized …

    unr Repository record for Experimental and Analytical Seismic Studies of a Four-Span Bridge System with Composite Piers (opens in a new tab)

  18. Concrete-filled fibre-reinforced polymer tubes for axial and flexural structural members

    The use of fibre reinforced polymers, FRP, in new structures is still limited to few demonstration projects. Innovative hybrid systems such as the concrete-filled FRP tubes are effective in facing the great demand for piling, poles, highway overhead sign structures and bridge components. The new …

    manitoba Repository record for Concrete-filled fibre-reinforced polymer tubes for axial and flexural structural members (opens in a new tab)

  19. Damage Threshold of Near-Cross-Ply and Angle-Ply Tubes Used in Concrete Filled FRP Tubes Loaded in Flexure

    Concrete-filled fibre-reinforced polymer (FRP) tubes (CFFTs) have been studied extensively, but a lingering question remains regarding the vulnerability of the exposed tube to accidental damage or vandalism. In this thesis, the effect of damage induced in the tubes on the flexural strength of CFFTs …

    queens Repository record for Damage Threshold of Near-Cross-Ply and Angle-Ply Tubes Used in Concrete Filled FRP Tubes Loaded in Flexure (opens in a new tab)

Page 1 of 2