Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 126 for “"FT-ICR"”.
-
FT-ICR studies of giant carbon fullerenes
FT-ICR studies of high mass $\rm (C\sb{>150})$ carbon clusters have brought insight to the controversial structures of carbon fullerenes. Laser vaporization followed by supersonic beam technique produced carbon clusters that directly injected into the bore tube of a 6 Tesla magnet. Mass spectra of …
-
FT-ICR studies of gallium arsenide cluster ions
… on a Fourier transform ion cyclotron resonance(FT-ICR) mass spectrometer with an external supersonic cluster source. Reaction of GaAs cluster cations with ammonia revealed that all cluster cations larger than seven atoms were most reactive near the 1/1 composition ratio of gallium/arsenic. The …
-
FT-ICR-massenspektrometrische Untersuchungen zur Fragmentierung isomerer Oligosaccharide
… ations-Ionenzyklotronresonanz-Massenspektrometer (FT-ICR-MS) verwendet. Maltopentaose (MP), Lacto-N-fucopentaose I (LNFP I) und Lacto-N-fucopentaose II (LNFP II) wurden zur Verbesserung der Absorption mit verschiedenen Chromophoren derivatisiert. Je nach verwendeter Ionenspezies des Derivats werden …
-
Fragmentierungsverhalten von Rhodamin-Farbstoffen unter Stoß- und Laser-Aktivierung im FT-ICR-Massenspektrometer
… Arbeit wurden die Fragmentierungseigenschaften von Rhodamin B und weiteren Stoffen mit einem Xanthen-Grundgerüst untersucht. Die Experimente fanden hauptsächlich in einem Fourier-Transform-Ionencyclotronresonanz-Massenspektrometer unter Aktivierung durch niederenergetische Stöße und …
-
Utveckling av metoder för att mäta isotopkvoter i kolesterol med FT-ICR-masspektrometri
… Ion Cyclotron Resonance mass spectrometry (FT-ICR-MS). Particular emphasis was placed on achieving efficient and reproducible ionization of this inherently challenging analyte. Method development was carried out in two stages. In the first phase, analytical parameters were optimized using a …
-
Transformation of soil organic matter in forest fire impacted watersheds elucidated by FT-ICR mass spectrometry
… ion cyclotron resonance mass spectrometry (FT-ICR MS) was critically evaluated for the analysis of SOM. Data processing methods for FT-ICR MS were investigated to improve compositional analysis. Laboratory-simulated and field-based burn samples were collected and used to investigate changes …
-
Characterization of Dissolved Organic Matter Released from Decomposing Wood in Denitrifying Bioreactors: An FT-ICR MS Study
… ion cyclotron resonance mass spectrometry (FT-ICR MS) for analysis of complex dissolved organic matter (DOM), using FT-ICR MS to analyze molecular-level changes in labile carbon over time remains a largely unexplored area of woodchip bioreactor (WBR) design and optimization. In this study, a …
-
Anion-Peptide Adduct Formation and Decomposition As Studied by Fourier Transform Ion Cyclotron Resonance (FT-ICR) Mass Spectrometry
… adducts with [Glu]Fibrinopeptide B. However, after multiple Na+/H+ exchanges, F- and CH3COO- do form stable adducts. This phenomenon can be rationalized by considering that Na+ cations serve to “block” the highly acidic sites, thereby forcing them to remain overall neutral. This leaves the less …
-
Chemisorption of hydrogen(2) and carbon monoxide on positive transition metal cluster ions in an FT-ICR apparatus
A new FT-ICR apparatus (Fourier Transform - Ion Cyclotron Resonance) has been developed, where clusters produced in a laser vaporization supersonic cluster source were efficiently injected and trapped in an elongated cylindrical Penning type ion trap located in the center of a magnetic field of 6 …
-
Integrated Computational and Experimental Platform for Characterizing Protein Isoforms and PTMs in Microbial Systems by Top-Down FT-ICR Mass Spectrometry
… and post translational modifications (PTMs) in microbial systems by top-down FT-ICR mass spectrometry. To accomplish this goal, we employed methodologies of microbial growth, intact protein and protein complex extractions, followed by sample preparation and then progressed to identification of …
-
FT-ICR studies of gas phase silicon cluster ion reactivity and a new model for predicting the structure of silicon clusters
… a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer has been designed and implemented. Cluster ions generated in the supersonic beam source are injected down the bore of the superconducting ICR magnet and trapped in an elongated cylindrical FT-ICR ion trap. Cluster ions can …
-
The factors and protocols that influence, accuracy, precision and uncertainty of accurate mass measurements by FT-ICR ms to validate the assignment of elemental composition
… ion cyclotron resonance mass spectrometry (FT-ICR MS) is a very powerful tool for undertaking accurate mass measurements because of its high resolving power and mass accuracy. The use of FT-ICR MS in a high-throughput environment is limited due to the need of operator intervention required …
-
Development and implementation of a FT-ICR mass spectrometer for the investigation of ion conformations of peptide sequence isomers containing basic amino acid residues by gas-phase hydrogen/deuterium exchange
… a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. Bimolecular reactions are monitored as a function of time providing exchange efficiencies and temporal distributions for the peptide ions. Results from these experiments indicated that position of the basic residue within …
-
An Integrated Experimental and Computational Approach to Proteomics: Scaling from High Resolution Qualitative Analysis to Quantitative Measurements with Confidence Evaluation
… ion cyclotron resonance mass spectrometry (FT-ICR-MS) and quantitative measurements with statistically derived confidence evaluation.</p> <p>Although FT-ICR-MS provides high-performance mass measurements, its potential has not yet been fully explored for proteomics applications. A novel …
-
Development of data processing methods for high resolution mass spectrometry-based metabolomics with an application to human liver transplantation
… (DI) Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) is becoming a popular measurement platform in metabolomics. This thesis aims to advance the data processing and analysis pipeline of the DI FT-ICR based metabolomics, and broaden its applicability to a clinical …
-
Unraveling biogeochemical cycling of carbon, sulfur and nitrogen with high resolution mass spectrometry: from California vineyards to thawing permafrost in Sweden
… frozen ground covering approximately one-fifth of the Northern Hemisphere's land—plays a crucial role in global biogeochemical cycles. These frozen soils are vast reservoirs, holding roughly twice the organic carbon found in the atmosphere and about half of the global subterranean organic …
-
Improved mass spectrometry characterization of organic compounds using analyte preconcentration and radio-frequency ionization.
… (VOCs) in real world samples, which are often present at low concentrations and within complex mixtures, require the use of efficient sampling techniques and versatile ionization sources. Presented research projects focus on the use of analyte preconcentration and radio-frequency …
-
The Nature, Origin and Preservation of Amide Organic Nitrogen in Organic Matter
… ion cyclotron resonance mass spectrometry (FT-ICR-MS) and nuclear magnetic resonance (NMR) spectroscopy I investigated the molecular amide composition in sedimentary/aqueous systems while reassessing their preservation and formation routes. Development of a suitable methodology is essential …
-
Laser annealing of silicon clusters
… transform ion cyclotron resonance apparatus (FT-ICR) so that the clusters were directly injected into the ICR ion trap. Mass-selected positive silicon cluster ions were levitated in the FT-ICR, and probed in chemisorption reactions with ethylene and ammonia. Clusters in the 36-51 atom size …
Page 1 of 7