Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 531 for “"FWHM"”.

  1. Fission fragment distribution measurements with time of flight - energy (ToF-E) spectrometers

    … of 1.5 amu full width at half maximum (FWHM) for light fission products and 3.0 amu FWHM for heavy fission products, operating with a 40 cm arm length, a stretched polypropylene entrance window (92 μg/cm2 thickness), and 30 μg/cm2 thick carbon conversion foils. Several methods for …

    colo-mines Repository record for Fission fragment distribution measurements with time of flight - energy (ToF-E) spectrometers (opens in a new tab)

  2. Modular multi-wire drift chambers for the TRIUMF QQD-spectrometer

    … this corresponds to a resolution of 1.97mm FWHM at the position of the scattering target. In the vertical direction, using a charge division method, the best achieved resolution was < 2mm FWHM per wire, which gives an angular resolution of 71mrads or 15mm FWHM at the target position. The …

    ubc Repository record for Modular multi-wire drift chambers for the TRIUMF QQD-spectrometer (opens in a new tab) Download PDF for Modular multi-wire drift chambers for the TRIUMF QQD-spectrometer (opens in a new tab)

  3. Investigations into the xenon chloride excimer laser

    … 48.48% Ne. The 308 nm laser output pulse had a fwhm of 20 ns and a peak power of 8.6 MW. When charged to 35 kV, the voltage inversion reached a peak of ~45 kV and dropped to zero in ~35 ns. The fwhm of the discharge current was 46 ns, with a peak current of 15.3 kA. The electron density in the …

    ubc Repository record for Investigations into the xenon chloride excimer laser (opens in a new tab) Download PDF for Investigations into the xenon chloride excimer laser (opens in a new tab)

  4. Fast timing using NaI crystals

    … obtained using two NE 102 plastic scintillators (FWHM: 640 psec) with that using a cooled Nal scintillator and a NE 102 scintillator (FWHM: 680-psee) showed that Nal is a satisfactory fast coincidence gamma ray detector at 185°K.

    ubc Repository record for Fast timing using NaI crystals (opens in a new tab) Download PDF for Fast timing using NaI crystals (opens in a new tab)

  5. Pulsed photoneutron source driven by electrons from laser wakefield acceleration

    … a cylindrical plasma channel of 60 um radius (FWHM) and 1.5 mm length (FWHM). Electron beams of ~80 pC with Gaussian energy distribution centered at 37MeV and a width of 30MeV (FWHM) were produced via laser wakefield acceleration. A 2D particle in cell (PIC) simulation was performed to study …

    texas Repository record for Pulsed photoneutron source driven by electrons from laser wakefield acceleration (opens in a new tab)

  6. Higher-Order Statistics and Normalized Decay Analysis for Detector Deadtime Characterization

    … decay curves with Full Width at Half Maximum (FWHM) analysis. Hybrid models incorporated paralyzable and non-paralyzable components with dead times of 2.5–50 microseconds and paralysis factors of 0.1–0.99. Results showed distinct sensitivity patterns among statistical measures. CV demonstrated …

    must-thes Repository record for Higher-Order Statistics and Normalized Decay Analysis for Detector Deadtime Characterization (opens in a new tab)

  7. Quantitative performance characterization of image quality and radiation dose for dental CBCT machine (CS9300)

    … air, and aluminum, respectively. The measured FWHM and spatial resolution were larger than the voxel size. FWHM were 0.49-0.65 mm; spatial resolution was 194.81-467.68. Dose distributions were symmetric about the rotation angle’s bisector. For large and medium FOVs at 4 mA, 80-90 kVp, and …

    ubc Repository record for Quantitative performance characterization of image quality and radiation dose for dental CBCT machine (CS9300) (opens in a new tab) Download PDF for Quantitative performance characterization of image quality and radiation dose for dental CBCT machine (CS9300) (opens in a new tab)

  8. Raman analysis of octocoral carbonate ion lattice disorder along a natural depth gradient, Kona coast, Hawai‘i

    … disorder (full width at half maximum height [FWHM] of ν1) and Mg content (ν1 position, Raman shift). The total lattice disorder was then partitioned into Mg-driven and non-Mg driven components (residual FWHM). The total lattice disorder and Mg content decreased significantly with increasing …

    hawaii Repository record for Raman analysis of octocoral carbonate ion lattice disorder along a natural depth gradient, Kona coast, Hawai‘i (opens in a new tab)

  9. An Investigation of Broadband Current Preamplification for Obtaining Simultaneous High-Resolution Energy and Time Information from Nuclear Radiation Detectors

    … yielded noise line widths as low as 2.35 key FWHM for the integrated current output shaped by a 1.6 microsecond time constant RC-RC filter. The noise line width measured for the gated current pulse shaped by the RLC filter was 2.70 kev FWHM compared to 2.76 key FWHM obtained, without gating, …

    utk-theses Repository record for An Investigation of Broadband Current Preamplification for Obtaining Simultaneous High-Resolution Energy and Time Information from Nuclear Radiation Detectors (opens in a new tab)

  10. Discrete NaI(TI) crystal detector optimization for small animal SPECT molecular imaging

    … spectral energy resolution, spatial resolution (FWHM), count rate, and tomograhic pre-clinical performance employing a 3D-OSEM algorithm with geometrical misalignment corrections. Camera gamma-ray sensitivity was calculated to be 3.5, 37 and 73 cps/[mu] Ci for the 0.5, 2 and 3 mm pinhole …

    missouri Repository record for Discrete NaI(TI) crystal detector optimization for small animal SPECT molecular imaging (opens in a new tab)

  11. Características das sparks espontâneas de Ca2+ em cardiomiócitos de ratos espontaneamente hipertensos submetidos ao treinamento e ao destreinamento físico.

    … confocal. As análises da amplitude, frequência, FWHM, FDHM, Tpico, Imax e τ das sparks foram feitas por meio do programa SparkMaster. Para as análises estatísticas foram usados os testes Kolmogorov-Smirnov, Shapiro-Wilk, Kruskal-Wallis e ANOVA two-way com teste post-hoc de Tukey. O nível de …

    brazil-ufv Repository record for Características das sparks espontâneas de Ca2+ em cardiomiócitos de ratos espontaneamente hipertensos submetidos ao treinamento e ao destreinamento físico. (opens in a new tab)

  12. Development of REBCO Tapes on Non-Metallic Flexible Substrates for RF Applications

    … were optimized to 2° full-width-at-half-maximum (FWHM) and 5.5° FWHM, respectively. LMO out-of-plane and in-plane texture values were optimized to 2.6° and 6.8° FWHM, respectively. Epitaxial GdYBCO was grown by an Advanced Metal Organic Chemical Vapor Deposition (A-MOCVD) on the buffered-YSZ …

    houston Repository record for Development of REBCO Tapes on Non-Metallic Flexible Substrates for RF Applications (opens in a new tab)

  13. Position-sensitive proportional counters using resistance-capacitance position encoding

    … spatial uncertainty was reduced to 28 &micro; fwhm for alpha particles and 100 &micro;fwhm for low-energy x rays (2 to 6 keV). Also, the signal processing time was reduced to 0.6 &micro;sec without seriously degrading the spatial resolution.</p><p>These results have opened new fields of …

    ut-knoxville Repository record for Position-sensitive proportional counters using resistance-capacitance position encoding (opens in a new tab)

  14. Plasmonic properties of subwavelength structures and plasmonic optical devices

    … well as a narrower full width at half maximum (FWHM) are observed. The asymmetry from the rectangular shape gives this structure high selectivity for light with different polarizations. Furthermore, the RCDC shape gives extra degrees of geometrical variables to 2D-MHA for tuning the location of …

    texas Repository record for Plasmonic properties of subwavelength structures and plasmonic optical devices (opens in a new tab)

  15. Dielectric characterization and dopant profile extraction using scanning capacitance microscopy

    … was shown that the full-width at half-maximum (FWHM), of the SCM dC/dV peak is correlated with the trap density (Dit) at the oxide-semiconductor interface. A theoretical model was developed in this work to allow Dit to be obtained from the extracted FWHM values.

    nus Repository record for Dielectric characterization and dopant profile extraction using scanning capacitance microscopy (opens in a new tab) Download file for Dielectric characterization and dopant profile extraction using scanning capacitance microscopy (opens in a new tab)

  16. Mousebed and anaesthetic delivery system for in vivo MRI

    … and motion. The full width at half maximum (FWHM) of the distribution gives an indication of the image quality. With arbitrary values for signal intensities, comparisons of FWHM between images can be fairly made comparing the ratio of the FWHM and mean of the signal intensity. Oscillating …

    manitoba Repository record for Mousebed and anaesthetic delivery system for in vivo MRI (opens in a new tab)

  17. Novel phosphorus precursors to group III-V semiconductor nanoparticles

    … 550 and 650 nm, with full width at half maxima (FWHM) between 68 and 128 nm.</p> <p><strong>Chapter 4</strong> explores the reactivity of N-, N,N-, and P-functionalised phosphinecarboxamides in solution. The effect of phosphinecarboxamide side-chain functionalisation on reactivity is also …

    oxford Repository record for Novel phosphorus precursors to group III-V semiconductor nanoparticles (opens in a new tab)

  18. Statistically designed experimental study of sol-gel based film coating scheme for high temperature super conductors and buffer materials and related manufacturing process cost evaluation

    … Through experimental data collected on omega FWHM, phi FWHM, and composition of orientations, a set of models was generated to characterize the epitaxial growth response to the processing factors consisting of thermal processing time, temperature, atmosphere, nickel surface roughness, degree …

    ut-knoxville Repository record for Statistically designed experimental study of sol-gel based film coating scheme for high temperature super conductors and buffer materials and related manufacturing process cost evaluation (opens in a new tab)

  19. Quickbird II Two-Dimensional On-Orbit Modulation Transfer Function Analysis Using Convex Mirror Array

    … system. MTF and Full Width at Half Maximum (FWHM) estimates for the satellite were then derived from the estimated PSF. The MTF and FWHM measurements obtained from the twodimensional model were validated, by comparing onedimensional slices of the PSF to results obtained previously using …

    sdstate Repository record for Quickbird II Two-Dimensional On-Orbit Modulation Transfer Function Analysis Using Convex Mirror Array (opens in a new tab)

  20. Sub-pixel event repositioning algorithms for Chandra X-ray astronomical imaging

    … Gaussian with full width half maximum (FWHM) about 2 to 4 microns. This fact indicates that the impact positions of photons that generate split events are near the pixel boundaries, instead of the pixel centers. Considering ACIS CCDs have pixel size of 24 microns, subpixel event …

    rit Repository record for Sub-pixel event repositioning algorithms for Chandra X-ray astronomical imaging (opens in a new tab)

Page 1 of 27