Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 39 for “"Facepiece"”
-
Simulation-based assessment for N95 filtering facepiece respirator
N95 filtering facepiece respirators (FFRs) are most commonly used for personal protection from exposures to respirable aerosol particles. FFR comfort and fit are two important parameters for FFR designers, manufacturers, users, and standards developers. Although experimental approaches for assess …
-
Quantitative Respirator Fit Testing: Probed Facepiece versus Probed Cartridge
… between quantitative fit testing using a probed facepiece and a probed cartridge. Four subjects were tested on four different respirators. The respirators used were MSA & 3M full and half face respirator. Each subject performed each method five times per respirator. The results indicated no …
-
Development of a low resistance facepiece for collection of expired gases
Thesis (M.S.)--Michigan State University. Dept. of Health, Physical Education, and Recreation, 1966
-
Performance Aspects of Filtering Facepiece Respirators Against Ultrafine Inert and Biological Particles
… of filter testing and performance of filtering-facepiece respirators (FFRs) were investigated with focus on particles in the ultrafine size range. Three specific aims were pursued in four related studies.</p> <p>In the first study, the contribution to measured concentration made by the ultrafine …
-
Design and Development of Electrospun Nanofiber Filter Media for Filtering Facepiece Respirators
Conventional filtering facepiece respirators (FFRs) rely on electrostatically charged meltblown polypropylene filter media, whose dependence on electrostatic charging introduces limitations in manufacturing consistency, performance stability during use, compatibility with decontamination …
-
Correlation of in-facepiece sampling methods using a simulated health-care workplace test.
For a number of years, it was assumed that the protection measured during a laboratory fit test was indicative of the protection provided by the respirator during actual use in the workplace. Beginning in the early 1980's, workplace protection factor studies were conducted to validate this …
-
Evaluation and development of methods for measurement of penetration of filtering facepiece respirators
… been linked to adverse health effects. Filtering facepiece respirators (FFRs) are widely used as a form of respiratory protection against diesel particulate matter (DPM) in occupational settings. The objective of this study was to evaluate NIOSH-certified R95 and P95 electret respirators …
-
Filtration Performance of a NIOSH-Approved N95 Filtering Facepiece Respirator With Stapled Head Straps
Certain models of NIOSH-approved filtering facepiece air purifying respirators are manufactured with stapled head straps. Depending on the manufacturer, these head straps may be stapled to the filter media itself. This may cause leakage through the filter media of the respirator, potentially …
-
Efficiency Measurement of N95 Filtering Facepiece Respirators against Ultrafine Particles under Cyclic and Constant Flows
… can be controlled by means of N95 filtering facepiece respirators (FFRs), widely used by industrial and healthcare workers. In this regard, investigation of N95 FFRs efficiency, against UFPs, under cyclic flow, in addition with constant flow, is very necessary, since cyclic flow represents …
-
Predicting Fit of Filtering Facepiece Respirators Through New Face Anthropometry and 3D Face Shape Acquisition
… on enhancing the fit and design of filtering facepiece respirators (FFRs). The study addressed the need for improved respirator fit, particularly in occupational settings where respiratory protection is paramount for safeguarding workers' health. Combining anthropometric analysis, …
-
Effect of Particle Concentration, Sealing Condition and Breathing Rate on Total Inward Leakage for N95 Filtering Facepiece Respirators
… on the penetration efficiency of filtering facepiece respirators (FFRs), hence, this study aims to study the effect of varying NaCl particle concentration, sealing condition and breathing rate on the TIL as a result of the filtering efficiency of the filters. To achieve this, we followed the …
-
An investigation of the relationship between respirator half-facepiece fit and facial anthropometry using three-dimensional laser scanning technology.
… relationship between industrial respirator half-facepiece fit and facial anthropometry, including three-dimensional parameters. The investigation included application of laser scanning technology to the measurement of faces. The goal was to identify facially-related variables that are worthy of …
-
New NIOSH Headforms: Developing Novel Methods for Fabricating a More Realistic Physical Headform and Custom Facepieces and Evaluating Existing Commercially-Available Respirators
… be determined whether a shift to five sizes of facepieces would improve fit factors. This can be attributed to the high cost of prototyping limiting the availability of the headforms to use in testing. This collection of studies is intended to be a starting point in the assessment of any …
-
Oxygen and Carbon Dioxide Levels During Qualitative Respirator Fit Testing
… qualitative fit test were performed with a full facepiece respirator. Then a quantitative and a qualitative fit test were performed with an N95 filtering facepiece respirator. Parameters measured include: subjects height, weight, and age, oxygen and carbon dioxide levels, air temperature, heart …
-
Analysis Of Activated Carbon Fiber (Acf) As Particulate Filtration And Volatile Organic Compound (Voc) Media For The Development Of A Dual-Air Purifying Facepiece Respirator
… air-purifying respirators (PAPRs), and filtering facepiece respirators (FFRs) with nuisance-level vapor protection, often limited by bulk, discomfort, high pressure drop, and misuse. We identified a need for alternative dual-exposure media and a respiratory protection device that is lighter, and …
-
Evaluation of Training Technique as a Means of Influencing Safety Knowledge, Risk Perception and Proper Respirator Donning Ability Among Respiratory Protection Users
… Fit Testing (QFT) after donning half- and full- facepiece negative pressure respirators was evaluated. Training methods were assessed in terms of donning instructions. Additional effects evaluated were respirator presentation order, age, education level and gender differences. Evaluation studies …
-
Collection efficiencies of airpurifying respirators containing electrostatic filter media
… air purifying cartridges and filtering facepiece respirators. Such media provides high collection efficiency while affording low breathing resistance to the wearer. The certification method used by National Institute for Occupational Safety and Health (NIOSH) is considered to represent …
-
An evaluation of the efficiency of various respiratory protective equipment, used within platinum processing
… hair influenced the seal efficiency of the facepiece. Three life-size mannequins, each connected to a personal sampling pump, were used to test the efficiency of respirators within three different work environments. It was found that the 3M 8822, 3M 6000, Moldex 8000 and Drager air-stream …
-
Effects of Faceseal Leakage, Combustion Material, Particle Size, Breathing Frequency and Flow Rate on the Performance of Respiratory Protection Devices
… devices, including an elastomeric full facepiece, an elastomeric half-mask, an N95 filtering facepiece respirator (FFR), and a surgical mask. Challenge aerosols included NaCl particles and combustion particles generated by burning different materials. This research effort consists of …
-
The effects of personal protective respirators on human motor, visual, and cognitive skills
… powered-air purifying respirator and full-facepiece respirator in terms of their effect on fine motor, visual and cognitive tasks. Thirty participants performed the Hand Tool Dexterity test, Motor-Free Visual Perception test (MVPT-3) and Serial Seven test. Each participant performed each …
Page 1 of 2