Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 12 of 12 for “"Fan Coil unit"”.
-
A MODELLING STUDY OF VARIABLE AIR-VOLUME FAN COIL UNIT (VAV-FCU)
… Energy consuming equipment such as chillers, fans, pumps and lights are sized to meet demands dictated by the building function. In particular, air-conditioning equipment must be . capable of meeting the building peak cooling load. Air-conditioning system is the largest single consumer of …
-
Experimental Investigation of a Direct Expansion Solar-Assisted Heat Pump
… the solar evaporator with a standard outdoor fan coil unit. A novel, dual-source (hybrid) direct expansion solar-assisted heat pump is proposed that integrates the fan coil and solar collector units into one component.
-
Empirical validation of building energy simulation software: DOE2.E, HAP and TRACE
… with terminal reheat (CAVRH), and four-pipe fan coil unit (4PFCU).;Three building energy simulation programs were used. The programs were DOE2, HAP and TRACE. These programs represent a wide range in the level of detail available for energy simulation software. Site weather data were used to …
-
Heating, ventilation and air conditioning system optimization: a study of the effect of climate, building design, system selection and control strategy on the energy consumption of a typical office building in London and Athens
… system with terminal re-heaters, or a four-pipe fan coil unit (FCU) system with fresh air supply from a central plant, using mainly a dynamic simulation tool and the response surface methodology. The evaluation of the energy performance of the HVAC systems is for two types of climate, using …
-
INDOOR AIR QUALITY AND ENERGY IMPLICATIONS IN THE USE OF VRV SYSTEM FOR OFFICE BUILDING
… the ceiling space instead of connecting to the Fan Coil Unit. In the case of subjective measurement, Building Symptoms index (BSI) was adopted for the statistical analysis. In general comparisons, the BSI computed for the occupant in the building installed with VRV system is seen to be …
-
ENERGY SAVINGS AND THERMAL COMFORT OF SEPARATE SENSIBLE AND LATENT COOLING AIR-CONDITIONING SYSTEMS
… comfort to occupants. Compared to the baseline fan-coil unit, the low ΔT indoor heat exchanger creates better thermal comfort in terms of reducing temperature stratification from head to feet by 0.8 K and providing higher operative temperature at the foot level in winter. Numerical models were …
-
Vzduchotechnika obecního úřadu
… Systém je doplněn návrhem cirkulačních jednotek Fan Coil.
-
Vzduchotechnika skladovací haly s řízenou vlhkostí vzduchu
… objektu je navržena kombinovaná klimatizace s fancoily. Část práce se zabývá návrhem klimatizace s řízenou vlhkostí vzduchu ve skladovací hale. Teoretická část se zabývá vodními systémy chlazení. Projektová část obsahuje vypracování projektové dokumentace vzduchotechnického zařízení.
-
Polyfunkční budova Brno Purkyňova
… je zabezpečené vodným systémom reverzných fancoilov. V serverovni je navrhnutý samostatný chladivový systém typu multisplit s dvoma nástennými jednotkami. Objekt zároveň využíva dažďovú vodu, ktorá je zhromažďovaná zo strechy a spevnených plôch do akumulačnej nádrže umiestnenej v južnej …
-
Vytápění a chlazení skladu potravin s administrativou
Cílem této diplomové práce je návrh systému vytápění, chlazení a přípravy teplé vody administrativního objektu se skladovací halou. Teoretická část práce se zaměřuje na vysvětlení principů průmyslového chlazení a přehled základních typů chladiv a chladících okruhů. Výpočtová část zahrnuje návrh …
-
Budova občanské vybavenosti
… Chlad bude distribuován pomocí jednotek fan – coil. Teplo bude distribuováno podlahovým topením. Obsahem třetí části diplomové práce je posouzení dětské skupiny z hlediska prostorové akustiky a optimalizací kritických místností – hrací místnost č. 101 a místnost keramické dílny č. 201. …