Implementation of arbitrary trajectory fast spin-echo sequence on a memory-limited permanent magnet MRI scanner
… used to acquire images with higher resolution at faster acquisition times. These trajectories, which are implemented using time-varying gradient waveforms, are often non-Cartesian to provide more flexibility in sampling density and location, allowing for more undersampling and artifact resistance. …
-
High-resolution diffusion imaging with DIFRAD-FSE (diffusion-weighted radial acquisition with fast spin echo) MRI
… due to motion. Following a diffusion-weighted spin-echo preparation, multiple radial lines of Fourier data are acquired using spin-echo refocusing. Data can be acquired in either 2D or 3D Fourier space. Motion correction is accomplished via one of four correction techniques: phase correction, …
-
High-resolution Diffusion-weighted Magnetic Resonance Imaging: Development and Application of Novel Radial Fast Spin-echo Acquisitions
… taken for this purpose was to utilize radial fast spin-echo data acquisitions, which have been shown to produce high-resolution DWI without artifacts due to magnetic field inhomogeneities. In addition, there is little image distortion in radial fast spin-echo DWI, which allows for direct …
-
Rychlé MRI metody
… metody. Popsané jsou zde metody EPI (Echo Planar Imaging), rychlé gradientní echo GRE, FSE (Fast spin echo) dále pak snapshot-FLASH a FISP (Fast Imaging with Steady Precession). Experimentální část práce se zabývá rychlou metodou FSE (Fast Spin Echo). Speciálně je zde vysvětlen a …
-
MRI of the brain and spinal cord in multiple sclerosis and other disorders: Technical developments and clinical applications
… imaging of the brain and in particular the spinal cord: the cord is of great significance in the development of disability in MS but has proved technically more demanding to study. In the first section of this work recent advances in pulse sequence design (including fast spin echo, fast …
-
Dynamic Black Blood Carotid Artery Wall Imaging
… demonstrate a retrospectively gated black blood fast spin echo MR imaging technique to capture the motion of the carotid arterial wall over the cardiac cycle. The sequence was validated in digital phantoms and tested for functionality, accuracy and repeatability in volunteers. Distensibility …
-
Analysis of Noise Power Spectra in MR Parallel Imaging
… without parallel imaging using the conventional spinecho pulse sequence.The study was conducted using a GEMS SIGNA Premier 3.0 T MR scanner alongwith a 48-channel head coil to obtain several volumetric images of a vendor QC headphantom to obtain a total of 17 different sets of images using three …
-
Die Darstellung der Seitenbänder des Hufgelenkes und ihrer Erkrankungen mit Hilfe der Magnetresonanztomographie am stehenden Pferd
… wurden anhand eines transversalen und frontalen Fast Spin Echo T2 gewichtet durchgeführt. Um den Ursprungsbereich des Kollateralbandes am Kronbein und den Ansatzbereich am Hufbein zu bewerten wurden zusätzlich Gradientenechos T1 und T2* gewichtet, sowie die STIR Sequenz genutzt. Die Verwendung …
-
A multi-echo spin echo wrist MRI dataset at 1 Tesla
… a new open dataset of fully sampled multi-echo spin echo (MESE) k-space data of the wrist, acquired on a 1 Tesla permanent magnet MRI system. The dataset includes gradient-echo (GRE) and MESE scans, enabling estimation of magnetic and radiofrequency field inhomogeneities as well as …
-
Development of diffusion weighted magnetic resonance methodology and its application in renal imaging
… DWI studies commonly make use of single-shot Echo-Planar Imaging (ss-EPI) techniques that are prone to suffering from geometric distortion. Fast spin-echo imaging techniques (e.g. Rapid Acquisition Relaxation Enhancement - RARE) are less susceptible image distortions and can be an alternative …
-
High resolution 3D diffusion tensor imaging for delineating neuronal architectures
… full brain coverage within 14.4 minutes and a 3D fast spin echo acquisition for achieving 0.8 x 0.8 x 1 mm3 resolution with reduced field of view coverage within 22 minutes. Acquisition techniques and post processing algorithms have also been developed for correcting/minimizing common artifacts in …
-
THE RELATIONSHIP OF THIGH MUSCLE COMPOSITION AND FAT WITH MUSCLE POWER AND PHYSICAL FUNCTION IN WOMEN WITH KNEE OSTEOARTHRITIS
… The calf was also scanned using 1.0T MRI with a Fast Spin Echo (FSE) sequence. Knee extensor and flexor isokinetic power was measured at 20% and 40% of individuals’ maximum voluntary isometric contraction (MVIC) torque, and surface electromyography (EMG) measured activation. We found no …
-
Development and optimisation of high-field MRI techniques
… B1 mapping method was implemented that is faster than pre-existing methods. A quick, automated Fourier-based analysis was also introduced that is robust to experimental errors. T2-weighted Fast Spin Echo (FSE) imaging is very common in clinical use. However its high field application has …
-
The natural history of primary progressive multiple sclerosis: Serial clinical and MRI evaluation and application of new spinal imaging techniques
… As many of these patients have a predominant spinal cord syndrome which is responsible for much of their locomotor disability, the development of several techniques aimed at optimising spinal cord imaging are described. These include two new MR sequences, fast FLAIR and 3-dimensional fast spin …
-
Novel Deep Learning Methods for Enhanced MRI Acquisition and Reconstruction
… Optimized variable flip angle schemes for 3D Fast Spin Echo imaging are identified that balance signal-to-noise ratio (SNR) and the point-spread function. In vivo evaluations at ultra-high field demonstrate that these optimized schemes substantially reduce image blurring, enhance visibility of …
-
Parameter Estimation in Magnetic Resonance Imaging
… estimation of the T2 relaxation parameter from fast spin-echo (FSE) data. Various complications are considered, including partial volume and data from multiple receiver coils along with the effects of the timing parameters on the accuracy of T2 estimates. Next, the problem of classifying small …
-
Relaxometry in the Human Brain Using High Field Magnetic Resonance Imaging
… profiles. T2 may be quantified using multi-echo spin echo sequences; however, in practical imaging situations, imperfect refocussing due to RF interference and imperfect slice profiles results in contamination of the signal decay curve by contributions from indirect and stimulated echoes. …