Results 1 to 8 of 8 for “"Fat/Water separation"”

  1. Joint estimation of water and fat images from magnetic resonance signals

    Fat-water separation is a classical problem for in vivo magnetic resonance imaging, with multiple applications both in cases where the aim is the removal of fat signal, as well as in cases where the fat signal itself is of diagnostic interest. Although many methods have been proposed, robust …

    uiuc Repository record for Joint estimation of water and fat images from magnetic resonance signals (opens in a new tab)

  2. Efficient Fat/Water Separated MRI: Applications in Musculoskeletal Imaging and Whole-Body Imaging in Multiple Myeloma

    In the realm of fat signal suppression methods in MRI, Dixon methods are unique in that they separate out water and fat proton signal, instead of purely saturating the fat signal, which allows for analysis of a water-only and a fat-only image. The work presented in this thesis focuses on a …

    utswmed Repository record for Efficient Fat/Water Separated MRI: Applications in Musculoskeletal Imaging and Whole-Body Imaging in Multiple Myeloma (opens in a new tab)

  3. Development of MR Thermometry Strategies for Hyperthermia of Extremity and Breast Tumors

    … These include magnetic field system drift, fatty tissue, and breathing motion.</p> <p>The purpose of this research was to develop a system for the hyperthermia treatment of LABC while performing MR thermometry. A hardware system was developed for performing the hyperthermia treatment within …

    duke Repository record for Development of MR Thermometry Strategies for Hyperthermia of Extremity and Breast Tumors (opens in a new tab)

  4. CONTINUOUS SAMPLING IN MAGNETIC RESONANCE IMAGING

    … CS sequence.</p> <p>A Cartesian CS Dixon fat/water separation techniques was developed by applying the Dixon echo time variation between CS echoes. The redundant data collected during CS produced two Dixon images in one acquisition. The CS Dixon resulted in equivalent fat suppression in …

    ohiolink Repository record for CONTINUOUS SAMPLING IN MAGNETIC RESONANCE IMAGING (opens in a new tab)

  5. Advanced Methods For Magnetic Resonance Image Reconstruction, Motion Artifact Correction And Quantitative Susceptibility Mapping

    … mapping technique capable of estimating water T1, water T2, fat fraction (FF), and R2*. Using a multi-echo 3D stack-of-spirals acquisition with inversion-recovery and T2-preparation, we designed an implicit neural representation–based fingerprinting method (FINR) that jointly reconstructs …

    cornell Repository record for Advanced Methods For Magnetic Resonance Image Reconstruction, Motion Artifact Correction And Quantitative Susceptibility Mapping (opens in a new tab)

  6. Cardiac magnetic resonance-based prediction of left atrial fibrosis as a feature of left atrial myopathy using left atrial epicardial adipose tissue volume quantification

    … the development of left atrial fibrosis by fibro-fatty infiltration. This corresponds to low voltage zones (LVZ), that are characterized by impaired myocardial electrical conduction during invasive electroanatomic mapping. Epicardial adipose tissue (EAT) has been revealed to be a key player in …

    qucosa-diss Repository record for Cardiac magnetic resonance-based prediction of left atrial fibrosis as a feature of left atrial myopathy using left atrial epicardial adipose tissue volume quantification (opens in a new tab)

  7. Methods to Improve Bone Marrow Dosimetry in Molecular Radiotherapy

    … imaging (MRI) for quantification of the fat volume fraction, and ii) to validate a method based on dual-energy quantitative computed tomography (DEQCT) for quantification of the trabecular bone volume fraction. In a first step, an MRI sequence (two-point Dixon) for fat-water separation …

    wurz-thes Repository record for Methods to Improve Bone Marrow Dosimetry in Molecular Radiotherapy (opens in a new tab)

  8. Suivi par thermométrie par imagerie par résonance magnétique (IRM) des ablations thermiques dans les tissus mous

    Les ablations thermiques constituent des alternatives prometteuses aux techniques conventionnelles, notamment pour le traitement de cancers. Le caractère minimalement invasif de ces thérapies contribue à réduire la morbidité et les effets secondaires, transformant ainsi la prise en charge des …

    star-france Repository record for Suivi par thermométrie par imagerie par résonance magnétique (IRM) des ablations thermiques dans les tissus mous (opens in a new tab)