Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 21 for “"Fat suppression"”
-
Fat Suppression and Segmentation in Phase-Contrast MRI Flow Measurements
… circulation, the neighboring structure is fat, and it surrounds the whole vasculature bed. Current methods of addressing the fat related artifacts and problems will be discussed. One of these methods, spatial-spectral excitation, is implemented for PC flow imaging with the temporal …
-
Robust Fat and Fluid Suppression in MR Imaging: Technical Developments and Advanced Clinical Applications
Fat and fluid suppression methods are widely used in MR imaging to improve the lesion conspicuity, reduce the artifacts, increase quantification accuracy etc. However, these methods often suffer from either low signal to noise ratio (SNR), incomplete fat suppression or long scan times in some …
-
Novel Chemically Selective Rapid Magnetic Resonance Imaging Techniques and the Clinical Applications
… methods for the generation of high quality fat-only or water-only images in short scan durations. High quality fat imaging is mainly used for human fat distribution measurements. The study of fat distribution is important for both clinical diagnosis and basic research. The abnormal …
-
REAL-TIME FLOW QUANTIFICATION TECHNIQUES IN CARDIOVASCULAR MRI APPLICATIONS
… resulting from the off-resonance effect of fat spins limit the use of long echo train length, which compromises acquisition speed of the EPI method. This work investigated the problem of off-resonance artifacts and developed a fat-suppression method not only applicable to the EPI but also to …
-
Positive Contrast Magnetic Resonance Imaging with Multifunctionalised Magnetic Nanoparticles
… Inversion Recovery with ON-resonant water suppression (IRON) and Susceptibility Gradient Mapping (SGM). <br/><br/>Four novel SPIONs of different sizes, coatings and surface charges were assessed in terms of their application as MR contrast agents. The !" and !" ∗ relaxivities in water and …
-
RAPID DIXON ACQUISITIONS FOR WATER / LIPID SEPARATION IN MRI
The main limitation of current lipid/water suppression techniques in MRI is that these methods significantly increase the overall acquisition time of the particular sequence. For example, the multi-point Dixon methods utilize multiple acquisitions at different echo times to algebraically calculate …
-
Παρακολούθηση των ασθενών με πρωτοπαθές γαστρικό λέμφωμα με μαγνητική τομογραφία
… with a 2-3mm interslice gap.T2 TSE images with fat suppression were acquired. Gadopentetate dimeglumine (Magnevist, Schering AG, Germany) or gadodiamide (Omniscan, Nycomed Amersham, England) was administered at a dose of 0.1mmol/kg as a rapid hand-injected bolus, prior to the enhanced images. …
-
Design of Pulse Sequences for Low-Field Cardiac MRI Using Bloch Simulations
… focusing on improving SNR, contrast, and fat suppression. Both sequences were assessed using quantitative and qualitative scores, achieving excellent image quality and vessel sharpness comparable to previous 1.5T studies.<br/><br/>Finally, a comparison between the optimized 0.55T sequences …
-
Möglichkeiten der Frühdiagnostik der Osteomyelitis durch Magnetresonanz-Tomographie - Experimentelle Untersuchungen am Kaninchen
… improvement in sensitivity. In the clinical use fat suppression and STIR-sequence have provided further improvement. The role of MRT as a diagnostic instrument in osteomyelitis is established in clinical medicine and seems promising in veterinary medicine.
-
Precisión diagnóstica de la resonancia magnética para el diagnóstico de apendicitis aguda en pediatría
… without contrast, using T2 sequences with fat suppression, balanced fast field echo (BFFE) and high resolution T2. The studies were interpreted by 3 readers with different degrees of experience, who reviewed the technical quality of the MRI, the visualization of the appendix, its transverse …
-
CONTINUOUS SAMPLING IN MAGNETIC RESONANCE IMAGING
… CS sequence.</p> <p>A Cartesian CS Dixon fat/water separation techniques was developed by applying the Dixon echo time variation between CS echoes. The redundant data collected during CS produced two Dixon images in one acquisition. The CS Dixon resulted in equivalent fat suppression in …
-
T2-gewichtete MR-Tomographie fokaler Leberläsionen ohne und mit dem i.v. Kontrastmittel Resovist®: Vergleich einer schnellen mit einer hochaufgelösten Sequenz
… liver-lesion contrast, artifacts and quality of fat saturation were qualitatively evaluated on a scale of 1–5. Two parameters were determined quantitatively: Liver-lesion contrast and the number of recognizable lesions depending on the lesion diameter (≤ 4 mm, 5-9 mm,> 9 mm). In addition, lesions …
-
Water-fat imaging and general chemical shift imaging with spectrum modeling
Water-fat chemical shift imaging (CSI) has been an active research area in magnetic resonance imaging (MRI) since the early 1980's. There are two main reasons for water-fat imaging. First, water-fat imaging can serve as a fat-suppression method. Removing the usually bright fatty signals not only …
-
MRT des Rektumkarzinoms: Wert der kontrastmittelgestützten Bildgebung für das präoperative Staging unter Berücksichtigung neuerer zeitsparender Bildaufnahmetechniken
Einleitung Der Nutzen der MRT für das Tumorstaging und damit zur Erstellung eines Therapieplanes und der Prognose ist heute unumstritten. Mehrere Studien zeigten die Überlegenheit der MRT gegenüber anderen gebräuchlichen Verfahren wie CT, ERUS oder PET(-CT). Der heutige Untersuchungsstandard …
-
Optimierung des Signalverhaltens von Steady State Sequenzen in der Kernspintomographie durch variable Flipwinkel
In dieser Arbeit wurde die bSSFP-Bildgebung durch die Anwendung von variablen Flipwinkeln bei der HF-Anregung hinsichtlich des Signalverhaltens, der HF-Leistung und des Bildkontrastes optimiert, um Nachteile der konventionellen bSSFP-Bildgebung zu lösen. <br>In der Arbeit wird dazu zunächst der …
-
Improving Quality of Prostate MRI
… performance in assessing prostate coverage and fat suppression. Overall, the tool demonstrates promise for improving standardization and quality assurance in prostate MRI. Finally, Chapter 7 will conclude this PhD thesis and propose some potential future works.
-
Water Fat Separation with Multiple-Acquisition Balanced Steady-State Free Precession MRI
… from the hydrogen nuclei contained in water and fat molecules.Reliable and uniform water fat separation can be used to improve medical diagnosis. In many applications the water component is the primary signal of interest, while the fat component represents a signal which can obscure the …
-
Bildqualität und Umsetzbarkeit der mDixon Methode bei peripherer arterieller Verschlusskrankheit in der 3 Tesla Magnetresonanztomographie
Hintergrund: Die periphere arterielle Verschlusskrankheit (pAVK) stellt eine Erkrankung der Gefäße mit einer hohen Prävalenz dar und geht für die Patienten mit einer erhöhten Morbidität und Mortalität einher. Um die Komplikationen invasiver Methoden zu vermeiden, hat die nicht- invasive Bildgebung …
-
Suivi par thermométrie par imagerie par résonance magnétique (IRM) des ablations thermiques dans les tissus mous
… de la graisse après différentes méthodes de suppression de la graisse. Cette approche a été caractérisée lors d’expériences in vitro et in vivo. La précision des mesures de thermométrie IRM PRFS a été ensuite mesurée pour plusieurs quantités de gras avec différentes méthodes de suppression. …
Page 1 of 2