Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 40 for “"Fault Ride Through (FRT)"”

  1. Control strategies of MMC-HVDC connected to large offshore wind farms for improving fault ride-through capability

    This paper proposes strategies to improve fault ride-through (FRT) capability of the modular multi-level converter (MMC) - high voltage direct current (HVDC) system connected to large offshore wind farms and performs simulations. In offshore wind power plants, HVDC system is indispensable for …

    umn Repository record for Control strategies of MMC-HVDC connected to large offshore wind farms for improving fault ride-through capability (opens in a new tab)

  2. Cybersecurity and Protection Strategies for Inverter-Based Resource Integration

    … of cyberattacks. Moreover, the unconventional fault behavior of IBRs can cause traditional protection schemes to misoperate. These difficulties are compounded by the black-box nature of IBR controllers, which makes it challenging to develop comprehensive cybersecurity and protection strategies. …

    vt Repository record for Cybersecurity and Protection Strategies for Inverter-Based Resource Integration (opens in a new tab)

  3. Diagnóstico del SCR para WPP en zona de Colectora 2 y 3

    … y de perturbaciones [1]; además, se verifica el Fault-Ride Through (FRT), que muestra la capacidad de una turbina eólica o generador eléctrico de permanecer conectada durante una caída o aumento de la tensión del sistema [2]. El sistema modelado resultó ser débil para soportar la generación …

    uniandes Repository record for Diagnóstico del SCR para WPP en zona de Colectora 2 y 3 (opens in a new tab)

  4. Modeling and investigation of fault ride through capability of variable speed wind turbines

    … speed wind turbines and the investigation of fault ride trough capability of the wind turbines for grid integration studies. In the thesis, detailed models of different variable speed wind turbines will be presented. Requirements of grid codes for wind power integration will also be discussed …

    metu Repository record for Modeling and investigation of fault ride through capability of variable speed wind turbines (opens in a new tab)

  5. Probabilistic short circuit calculation and its application in voltage sag estimation considering fault ride through of distributed generator

    Short circuit (SC) fault is one of the most severe disturbances faced by the power system. The traditional worst cases based SC calculation concept ignores the random nature of factors affecting SC current and only gives maximum and minimum SC current results. In this paper, the stochastic behavior …

    eindhoven Repository record for Probabilistic short circuit calculation and its application in voltage sag estimation considering fault ride through of distributed generator (opens in a new tab)

  6. Consideration of the effects of symmetrical and asymmetrical voltage dips in the control and operation of a grid-connected doubly-fed induction generator.

    … focused on the control aspects of the DFIG. The fault ride-through (FRT) capability of the 0.8 kW DFIG test bench is also analyzed in this research. It is deduced that it is possible to control a DFIG WECS during voltage dips that are less than 32 % in depth by solely using the traditional dual …

    ukzn Repository record for Consideration of the effects of symmetrical and asymmetrical voltage dips in the control and operation of a grid-connected doubly-fed induction generator. (opens in a new tab)

  7. Stability Analysis of grid-connected solar PV systems under asymmetrical faults.

    … solar PV systems during asymmetrical fault conditions remains a challenge. Voltage and current imbalances can spread across the network, potentially leading to cascading faults and widespread instability. This study examines the stability of grid-connected solar PV systems under …

    ttu Repository record for Stability Analysis of grid-connected solar PV systems under asymmetrical faults. (opens in a new tab)

  8. Estudio de viabilidad técnica y económica de cables superconductores HVDC HTS para la evacuación de energía eólica costa afuera en el Caribe colombiano

    … llevaron a cabo estudios de flujo de carga, SCR, FRT, así como un análisis de viabilidad económica mediante el cálculo del Valor Presente Neto (VPN). A partir de los resultados técnicos obtenidos con el flujo de carga, se determinó que la solución HVDC HTS es viable para evacuar 2000 MW costa …

    uniandes Repository record for Estudio de viabilidad técnica y económica de cables superconductores HVDC HTS para la evacuación de energía eólica costa afuera en el Caribe colombiano (opens in a new tab)

  9. Control and operation of wind power plants connected to DC grids

    … wind power plants (WPPs) are being linked through high-voltage de voltage-source converter (VSC-HVdc) transmission to the main grids. The current deployments of HVdc grid connections for offshore WPPs are point-to-point transmission systems. Moreover, WPPs connected to the offshore VSC-HVdc …

    barcelona Repository record for Control and operation of wind power plants connected to DC grids (opens in a new tab)

  10. Application of Series Compensation to Improve the Voltage Stability and Power Quality of Wind Farms

    … converter (VSC) based series compensation on the fault levels of symmetrical and asymmetrical faults. From stability and power quality analyses, the cases studied show that large-scale wind power penetration substantially degrades the voltage stability but that series compensation can enhance the …

    unsw Repository record for Application of Series Compensation to Improve the Voltage Stability and Power Quality of Wind Farms (opens in a new tab)

  11. Performance Assessment and Management of Large Wind Farms under Abnormal Grid Operating Conditions

    … stability following its large scale integration. Fault responses and protection schemes are currently not standardized and neither following consistent practices for existing wind farms which provides research opportunities. This is because different wind generation technologies exhibit diverse …

    auckland-ms Repository record for Performance Assessment and Management of Large Wind Farms under Abnormal Grid Operating Conditions (opens in a new tab)

  12. Grid-forming converter control for modern high-voltage transmission networks

    … the GFM-STATCOM control. The impact of different fault locations on the fault ride-through (FRT) performance of the GFM-STATCOM is analyzed and compared using both time-domain simulations and scanning methods. Finally, based on the experience and results obtained from PSCAD modeling, control …

    barcelona Repository record for Grid-forming converter control for modern high-voltage transmission networks (opens in a new tab) Embargoed

  13. Advanced Current-limiting Control of Inverter-interfaced Distributed Energy Resources to Develop Self-Protected Microgrids

    … under a lower value than its maximum during faults, the proposed controller fully utilizes the inverter capacity. An inherent current limitation is proven through nonlinear ultimate boundedness theory and is shown to facilitate the operation of Fault-Ride-Through (FRT) schemes. Furthermore, …

    whiterose Repository record for Advanced Current-limiting Control of Inverter-interfaced Distributed Energy Resources to Develop Self-Protected Microgrids (opens in a new tab)

  14. Power System Stability Enhancement through Data Center Ancillary Services

    … performance under varying dynamics, such as faults and disturbances. The stable power system should continue to function properly in case of faults and disturbances. Stability of the power systems find applications in various domains, such as power delivery through Permanent Magnet …

    ndsu Repository record for Power System Stability Enhancement through Data Center Ancillary Services (opens in a new tab)

  15. Advanced current-limiting control of inverter-interfaced distributed energy resources to develop self-protected microgrids

    … under a lower value than its maximum during faults, the proposed controller fully utilizes the inverter capacity. An inherent current limitation is proven through nonlinear ultimate boundedness theory and is shown to facilitate the operation of Fault-Ride-Through (FRT) schemes. Furthermore, …

    greece Repository record for Advanced current-limiting control of inverter-interfaced distributed energy resources to develop self-protected microgrids (opens in a new tab)

  16. Power System Dynamic Control and Performance Improvement Based on Reinforcement Learning

    … Doubly-fed Induction Generator (DFIG) based Fault-Ride-Through (FRT) system, and modified IEEE-39 Bus based frequency regulation system. In the case of the HVDC-based system, the proposed GSES-based power oscillation damping control approach overcomes the challenges of setting optimal …

    denver Repository record for Power System Dynamic Control and Performance Improvement Based on Reinforcement Learning (opens in a new tab)

  17. Εφαρμογή τεχνικών υπολογιστικής νοημοσύνης για την αδιάλειπτη λειτουργία συστημάτων ηλεκτρικής ενέργειας με ανεμογεννήτριες

    … of intelligent control techniques in the Fault Ride-Through (FRT) of grid connected Wind Turbines (WTs). The first part of the dissertation studies the issue of the fault ride-through capability of a wind farm of induction generators, which is connected to an ac grid through an HVDC link …

    greece Repository record for Εφαρμογή τεχνικών υπολογιστικής νοημοσύνης για την αδιάλειπτη λειτουργία συστημάτων ηλεκτρικής ενέργειας με ανεμογεννήτριες (opens in a new tab)

  18. Durchfahren von Netzfehlern bei Windenergieanlagen mit FACTS

    … besser bekannt unter dem englischen Begriff Fault Ride Through (FRT). In dieser Arbeit wird die FRT Fähigkeit moderner, stromrichtergespeister WEA als Einzelsystem, sowie in Kombination mit Flexible AC Transmission Systems (FACTS) untersucht. Nach einer Einleitung in Kapitel 1 werden in …

    cau-kiel Repository record for Durchfahren von Netzfehlern bei Windenergieanlagen mit FACTS (opens in a new tab)

  19. Comparison of low voltage ride through capabilities of synchronous generator with STATCOM and DFIG based wind farms

    … wind energy systems to enhance grid performance through fault ride-through capabilities, providing voltage control and power quality improvement etc. The goal of a Fault Ride Through (FRT) or Low Voltage Ride Through (LVRT) system is to enable a wind farm (WF) to withstand a severe voltage dip at …

    cape-town Repository record for Comparison of low voltage ride through capabilities of synchronous generator with STATCOM and DFIG based wind farms (opens in a new tab)

  20. Integration improvement of DFIG-based wind turbine into the electrical grid

    … in three parts: The first part treats the Fault Ride Through (FRT) capability of the Grid-connected DFIG-based Wind Turbine. The first proposed approach is a hybrid method combining two methods (active and passive methods): The active method aims to develop the control of DFIG. In contrast, …

    upc-spain Repository record for Integration improvement of DFIG-based wind turbine into the electrical grid (opens in a new tab)

Page 1 of 2