Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 45 for “"Fault behavior"”
-
Fault Behavior of Wind Turbines
… synchronous generation under many circumstances. Fault behavior is an important example. This thesis deals with the behavior of wind turbines during faults in the grid. The first part focuses on the fault currents delivered by wind turbines with Doubly-Fed Induction Generators (DFIG). The second …
-
Electrical Characterization of Arcing Fault Behavior on 120/208V Secondary Networks
Arcing faults have been a persistent problem on power systems for over one hundred years, damaging equipment and creating safety hazards for both utility personnel and the public. On low-voltage secondary networks, arcing faults are known to cause specific hazards collectively called "manhole …
-
Geomorphic analyses of young faulting and fault behavior in central Nevada.
This dissertation research assesses the behavior of young faults in central Nevada through analyses of landforms associated with these faults. Four large earthquakes have occurred since 1915 in a striking N-S belt in central Nevada; no comparable earthquakes have occurred elsewhere in the Great …
-
Fault Behavior and Kinematic Evolution of the Eastern California Shear Zone
… sedimentation, and near-field deformation of a fault system may be characterized to obtain an understanding of its kinematic evolution and potential seismic hazards. The dynamics and deformation history of the Eastern California shear zone (ECSZ), a wide and complex network of right-lateral …
-
IMPLICATIONS FOR MODELS OF FAULT BEHAVIOR FROM EARTHQUAKE SURFACE-DISPLACEMENT ALONG ADJACENT SEGMENTS OF THE LOST RIVER FAULT, IDAHO
This research evaluates models of earthquake behavior and fault segmentation, by quantifying the rupture-magnitude pattern along the trace of coseismic surface rupture for each of four earthquakes. One is the 1983 (Ms = 7.3) Borah Peak, Idaho, earthquake and three are prehistoric. Two earthquakes …
-
A Novel Inverter Based Resource Control Strategy to Facilitate Utility-Scale Renewable Integration and Retain Existing Transmission Protection Infrastructure
… inverters have a significantly different fault response than conventional synchronous generators. The existing protection infrastructure for the North American transmission network was not designed with the behavior of these Inverter Based Resources (IBR) in mind. As IBR penetration …
-
Modeling of Power Consumption and Fault Tolerance for Electronic Textiles
… performance, limited power consumption, and fault tolerance. The purpose of this research is to create simulation models for power consumption and fault behavior of e-textile applications. For the power consumption model, the power profile of the computational elements must be tracked …
-
Deformation Across The Seismic Cycle In Tectonically Active Regions: Imaging, Modeling, And Interpretations
… o n spatially and temporally variable fault behavior across the seismic cycle. Models of fault behavior inferred from these observations in turn allow us to address topics in geologic hazards assessment, the long- a nd short - term character of strain in defor ming regions, and the …
-
Cybersecurity and Protection Strategies for Inverter-Based Resource Integration
… of cyberattacks. Moreover, the unconventional fault behavior of IBRs can cause traditional protection schemes to misoperate. These difficulties are compounded by the black-box nature of IBR controllers, which makes it challenging to develop comprehensive cybersecurity and protection strategies. …
-
Fault Modeling and Analysis for FinFET SRAM Arrays
… FinFETs offer an excellent short channel behavior and enables scaling of transistors to continue further. Also, they offer circuit designers a unique way of balancing performance and leakage power consumption by way of their dual gate structure that allows to alter their threshold voltage …
-
Implementation of Adaptive Protection Scheme for Microgrid using IEC 61850 Communication Protocol
… of the conventional protection scheme, fault behavior of inverter interfaced DERs, and impact on the coordination of relays. The thesis also proposes the adaptive protection algorithm to be applied with extensive IEC 61850 communication protocol between Microgrid Central Protection Unit …
-
Distance Protection Challenges of Converter-Interfaced Renewable Energy Sources
… vicinity. Such failure stems from the different fault behavior of CIRESs compared to synchronous generators (SGs), based on which existing relays have been developed. Several measures have been devised to improve the performance of distance protection by modifying existing relays. This thesis …
-
Paleoseismic and Structural Investigations of active faulting in Western Nepal and Southern California
… crust is commonly distributed across complex fault systems rather than confined to single fault planes, reflecting interactions among fault geometry, stress state, and inherited crustal structure. This dissertation investigates how strain is accommodated and preserved within active fault …
-
Kaltė kaip santuokos nutraukimo pagrindas /
Fault as the grounds for divorce is analyzed in this Master’s paper. The paper is divided into three major sectiones. A thorough analysis of the concept of fault in family law is provided in the first part of this paper. The biggest attention in this section is paid to the interpretation of the …
-
Fault Attacks on Cryptosystems: Novel Threat Models, Countermeasures and Evaluation Metrics
… side-channel leakage and active attacks based on fault injection. Fault behavior can be processed as side-channel information, offering all the benefits of Differential Power Analysis including noise averaging and hypothesis testing by correlation. In fault attacks, the adversary induces faults …
-
Quantitative risk assessment and mitigation through fault diagnostics for automated vehicles
… is deemed essential, especially in the event of faults. The ISO 26262 functional safety standard is utilized to evaluate the risks associated with malfunctions in electrical/electronic (E/E) systems, based on a subjective assessment by safety experts. Yet, this standard primarily relies on …
-
Current derivative based fault detection and localization in a ring bus DC microgrid
… in PSCAD simulation software to understand the fault behavior and protection requirements. Protection related features such as grounding circuits and DC circuit breakers were also included in the model. Analytical expressions for the initial fault currents were developed considering simplified …
-
IMPEDANCE-BASED FAULT LOCATION METHODS FOR TRANSMISSION LINE CONNECTING WIND FARM PLANTS
… the world, the impact of wind generation during fault condition has been studied. Wind plants equipped with induction generator results in a different fault behavior in transmission networks. In this paper, the validation of existing impedance-based fault location methods are performed on a …
-
Utilizing the connected power electronic converter for improved condition monitoring of induction motors and claw-pole generators
… generators, they also significantly alter the fault behavior of these electric machines and complicate the fault detection and protection. In this dissertation, special characteristics of the connected closed-loop inverter and rectifier have been thoroughly analyzed, with particular interest in …
Page 1 of 3