  1. Network studies and mitigation of high 132 kV fault currents in eThekwini electricity.

    … that power networks are experiencing increased fault current levels. This is as a result of growth in demand which has led to interconnected networks and increases in generation capacity. Fault current levels have been increasing steadily and are at a point where mitigation measures have to be …

    ukzn Repository record for Network studies and mitigation of high 132 kV fault currents in eThekwini electricity. (opens in a new tab)

  2. Impact Of Fault Current Limiters And Demand Response On Electric Utility Asset Management Programs

    Over-currents are known to be the dominant cause of power system component failures or deterioration from full functionality. Some of these effects may remain unknown and could later result in catastrophic failures of the entire or large portions of the system. There are plenty of devices/methods …

    nodak Repository record for Impact Of Fault Current Limiters And Demand Response On Electric Utility Asset Management Programs (opens in a new tab)

  3. Clearing of single phase to ground faults

    … selective clearing of single phase to ground faults. Actual fault currents are sometimes lower than calculated, and directional relays sometimes determine the wrong direction. Considering lower than calculated fault currents, the paper proposes several adaptions to present fault calculations …

    eindhoven Repository record for Clearing of single phase to ground faults (opens in a new tab)

  4. Turboelectric Aircraft DC Network Fault Analysis and Protection Solution using Superconducting Fault Current Limiters

    … protecting the DC distribution system against faults. It is a significant challenge due to the high magnitude of fault currents, the absence of zero-crossing points, low line impedance and high bus voltage (6 kVDC). As the expected fault currents have a high magnitude and a short rise time in …

    bath Repository record for Turboelectric Aircraft DC Network Fault Analysis and Protection Solution using Superconducting Fault Current Limiters (opens in a new tab)

  5. Operating strategies to preserve the adequacy of power systems circuit breakers

    … results in increased short-circuit or fault currents levels. As fault currents increase, they will eventually exceed circuit breaker ratings. Circuit breakers exposed to fault currents in excess of their ratings are said to be overstressed, underrated, or inadequate. Insufficient …

    gatech Repository record for Operating strategies to preserve the adequacy of power systems circuit breakers (opens in a new tab)

  6. AN INTEGRATED OF CONTROL AND PROTECTION SCHEME FOR AC MICROGRIDS

    … effective in protecting the microgrid against fault currents, either in grid–connected or islanded mode. In microgrid framework, distributed generation (DG) based RES require an interface of power electronic converters to regulate their output voltage, current, and frequency as well as to share …

    msu Repository record for AN INTEGRATED OF CONTROL AND PROTECTION SCHEME FOR AC MICROGRIDS (opens in a new tab)

  7. Contribuição ao melhoramento da operação durante afundamentos de tensão de geradores de indução duplamente alimentados baseados em conversores modulares multinível

    … a fundamental challenge which is to provide fault support. Given this problem’s relevance, this thesis proposes improving DFIG supportability to a voltage sag in the grid through a recent multilevel converter topology, the Modular Multilevel Converter (MMC). The inherent MMC arm impedance and …

    brazil-ufrn Repository record for Contribuição ao melhoramento da operação durante afundamentos de tensão de geradores de indução duplamente alimentados baseados em conversores modulares multinível (opens in a new tab)

  8. Power System - Fault Clearance with Limited Fault Current

    … technical challenges, particularly in fault current management. This thesis explores the evolving challenges and solutions in power system protection as the share of converter interfaced generators continues to grow in response to global ambitions for reducing greenhouse gas emissions. …

    chalmers Repository record for Power System - Fault Clearance with Limited Fault Current (opens in a new tab)

  9. Simulation of power station protection equipment

    … relays for radial power systems under estimated fault current conditions. The grading curves for these protection devices can be produced on a graphics terminal and a hard copy can be obtained. Additional programs have also been developed which could be used to assess the validity of relay …

    aston Repository record for Simulation of power station protection equipment (opens in a new tab)

  10. The application of artificial neural networks to transformer protection

    … Networks to identify the magnetizing inrush currents that may occur in transformers is developed in this thesis. It is based on the fact that the magnetizing inrush current has large harmonic components. A feed-forward neural network (FFNN) has been trained using the back-propagation …

    ubc Repository record for The application of artificial neural networks to transformer protection (opens in a new tab)

  11. Time-Domain Line Protection in Presence of Renewables

    … into the power grid. However, their unique fault characteristics, significantly different from synchronous generators (SGs), present several challenges for existing line protection schemes at both transmission and distribution levels. These schemes, reliant on distance and directional relays …

    clemson Repository record for Time-Domain Line Protection in Presence of Renewables (opens in a new tab)

  12. A three phase short circuit analysis of the Naval Weapons Laboratory electrical distribution system

    … and a complete tabular presentation of maximum fault currents available at all critical locations is given. The study also includes one-line reactance diagrams for the entire system.

    vt Repository record for A three phase short circuit analysis of the Naval Weapons Laboratory electrical distribution system (opens in a new tab)

  13. Investigation of disintegration and arcing in electric fuses

    … of the fuse elements when subjected to excessive fault currents. The basis of the study involved experimental observation of disintegration of fuse elements and the analysis of the dynamic responses of current-carrying conductors, which precipitate disintegration. The experimental techniques …

    sheffield-hallam Repository record for Investigation of disintegration and arcing in electric fuses (opens in a new tab)

  14. Sequence Components Based Detection and Classification of Faults in an Islanded Distribution System with 100% Inverter Based Resources

    … reclosers fail to coordinate for bidirectional fault currents flowing in such a system, jeopardizing the selectivity of protection. When these resources are Inverter Based Resources (IBRs), even detection and classification of faults becomes an issue due to lack of negative and zero sequence …

    clemson Repository record for Sequence Components Based Detection and Classification of Faults in an Islanded Distribution System with 100% Inverter Based Resources (opens in a new tab)

  15. Increasing wind energy integration into power grids using multifunctional superconducting devices design

    … that affect grid stability.<br/>In addition, faults can occur in the power system as a result of a variety of sudden events, such as lightning striking the power line or utility poles shorting the power lines to ground. With higher penetration of wind farms into existing power grids, short …

    bath Repository record for Increasing wind energy integration into power grids using multifunctional superconducting devices design (opens in a new tab)

  16. Specification, Placement, and Control of Fault Current Limiters In Power Systems

    This dissertation focuses on the application of fault current limiters (FCLs) in power systems. The formula for the maximum first-peak fault current is derived to assist in specifying inductive FCLs. The specification process can be used to design and select proper FCL devices in a particular power …

    south-carolina Repository record for Specification, Placement, and Control of Fault Current Limiters In Power Systems (opens in a new tab)

  17. ACTIVE CURRENT INJECTION METHOD FOR LIMITING GROUND FAULT CURRENT HARMONICS IN UNDERGROUND COAL MINES

    … systems is to attempt to limit ground fault current to 25 Amperes and de-energize the circuit at 10 Amperes. However, the significant amount of system capacitance due to the use of shielded cables can cause ground fault current to be two or three times the intended ground fault limit. …

    uky-thes Repository record for ACTIVE CURRENT INJECTION METHOD FOR LIMITING GROUND FAULT CURRENT HARMONICS IN UNDERGROUND COAL MINES (opens in a new tab)