Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 19 of 19 for “"Fault level"”.
-
Enhanced static voltage stability and short circuit monitoring performance and optimization of future onshore AC power systems
… imposed on the network. These include fault level headroom constraints in MV distribution networks and steady state stability limits in transmission networks during periods of high power transfer. Specifically, a perturbation-coefficient based recursive least square (RLS) passive fault …
-
?Dynamic interactions between voltage and frequency events in future power systems
… characterised by a reduction inthe inertia and fault levels on the system, which, in turn, alter the sensitivity of the system’s frequency and voltages to changes in operating conditions. This Thesis investigates the changing dynamic behaviour of the power system in response to network faults, …
-
Hipoidinės pavaros gedimų šablono atpažinimas naudojant autoenkoderį ir giliuosius neuroninius tinklus /
This bachelor thesis investigates the fault pattern recognition of hypoid gears using autoencoders and deep neural networks. The study focuses on developing an efficient classification model to identify and categorize the fault patterns of hypoid gear conditions based on vibration signal data. …
-
Investigation of Generating Systems for a DC Connected Wind Turbine
… being the deciding factor, it doesn t work. Fault level and consideration of the number of turbines for a given amount of wind power significantly affects the flicker emission value. The results given in this master s thesis can be used to determine the ratings of the wind turbines which can …
-
A current-only faulted section identification scheme for power system protection
This thesis presents a faulted section identification scheme designed for modern distribution networks, which is applicable to power system protection and/ or to the emergent "fault location, isolation, and service restoration" (FLISR) set of functions (often also termed "distribution automation" …
-
Integration of Wind Energy Converters into an Existing Distribution Grid
… being the deciding factor, it doesn t work. Fault level and consideration of the number of turbines for a given amount of wind power significantly affects the flicker emission value. The flicker emission level doesn t seem to be a limiting factor when modern variable speed turbines are …
-
Anti-islanding schemes for machine-based distributed generation
… between the local load and DG power generation level. However, there is a possibility that the system voltage and frequency will be maintained within the specified limits following loss of the grid in cases where the load and generator are matched. Therefore, special means are required to detect …
-
Protection of future power systems with high amounts of power electronic converters
… Resources (CBRs) cannot generate high magnitude fault currents and their fault characteristics are dependent on implemented control strategies, which are governed by the associated grid codes. Those features of CBRs can pose severe challenges to the reliable operation of protection systems …
-
Electrical signal based fault detection and diagnosis for rooftop units
Fault detection and diagnosis (FDD) technology, as an effective approach, could identify the occurrence of common faults on rooftop units (RTUs) at the initial stage and prevent them from becoming severe. Although great progress have been made on the approaches, algorithms, control integration and …
-
AN INTEGRATED SCHEME FOR PROCESS FAULT DIAGNOSIS
Fault detection and diagnosis is currently a very important problem in process automation because of the increasing demands on reliability and safety. Current techniques include model-based methods, expert systems and the use of artificial neural networks. A particular form of neural networks, the …
-
Assessment Of Overcurrent Relay Coordination In A Microgrid With High PV Penetration Deployment
… configuration of the microgrid, addition of fault current due to presence of DERs, bidirectional power flow, islanding and grid connected operation of the microgrid. The bidirectional power flows imposed by DERs together with continual fault-level variation caused by different operating modes …
-
Protection challenges in future converter-dominated power systems : investigation and quantification using a novel flexible modelling and hardware testing platform
… source converter (VSC) model with controllable fault response has been developed and this is tested using realistic network data (including transmission lines and the corresponding power flow/fault level data) from the GB transmission network, provided by National Grid ESO (the research project …
-
Protection-based Distributed Generation Penetration Limits on MV feeders - Using Machine Learning
… present in the distribution network data i.e. fault level, Inverse Definite Minimum Time (IDMT) curve, pick-up current settings, Time Multiplier Settings (TMS), calculated relay operating times and relay positions to see how the network responds at certain DG penetration levels (‘actual' relay …
-
Evaluation of system strength in a converterdominated power system
… conducted in phase 2 identified the Available Fault Level (AFL), Equivalent Short Circuit Ratio (EqSCR), and Site-Dependent Short Circuit Ratio (SDSCR) as the most appropriate alternative metrics for evaluating grid strength. While the AFL demonstrated promise in the initial small-scale review, …
-
Fault Analysis in MMC-based Multi-terminal HVDC and MVDC Systems
Direct current (DC) faults represent a significant threat to modular multilevel converter (MMC)-based DC networks, as they can result in a substantial increase in normal operating currents and potentially lead to failures of power converters and even the complete DC network. To prevent detrimental …
-
Induction motor parameters estimation and faults diagnosis using optimisation algorithms.
… parameters are influenced by not only the load level but also environmental factors, such as temperature, humidity and lubricant viscosity. The first part of the thesis describes the application of the sparse grid optimisation method in solving the induction motor parameter estimation problem. …
-
Performance Assessment and Management of Large Wind Farms under Abnormal Grid Operating Conditions
… stability following its large scale integration. Fault responses and protection schemes are currently not standardized and neither following consistent practices for existing wind farms which provides research opportunities. This is because different wind generation technologies exhibit diverse …
-
Optimal cost versus efficiency configuration of a grid-connected photovoltaic system exploiting the weighted-sum method with focus on Kuwaiti National Grid
… in ERACS and it’s used to conduct power flow and fault studies. Four network locations were chosen as potential sites to connect the PV system. Power flow studies were conducted on the network for every hour that the PV array contributed power to the network and for 35 different network …
-
Vliv OZE na elektrizační soustavu ČR
Tento text pojednává o obnovitelných zdrojích energie z hlediska působení na elektrizační soustavu České republiky. V práci je uvedena definice obnovitelných zdrojů energie. Dále jsou zde rozebrány základní informace o připojovacích podmínkách do distribuční soustavy. Ve dvou kapitolách je zmíněna …