Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 51 for “"Field Calibration"”.

  1. Characterization, Modeling of Piezoelectric Pressure Transducer for Facilitation of Field Calibration

    … in the engineering community to develop a field calibration technique concerning piezoelectric pressure sensor to reduce cost and improve reliability. This paper summarizes the algorithm used to characterize and develop a model for a piezoelectric pressure transducer. The basic concept of …

    vt Repository record for Characterization, Modeling of Piezoelectric Pressure Transducer for Facilitation of Field Calibration (opens in a new tab)

  2. Field Calibration of Time-Dependent Behavior in Segmental Bridges Using Self -Learning Simulation

    The method integrates computational simulation and construction. It can be applied to characterize any material behavior, including the time-dependent behavior of concrete in segmental bridges. The study presents a scheme to improve the camber of segmental bridges using a self-learning simulation.

    uiuc Repository record for Field Calibration of Time-Dependent Behavior in Segmental Bridges Using Self -Learning Simulation (opens in a new tab)

  3. Hydrogen Isotopes from Lipid Biomarkers: Purification, Field Calibration, and Application to Reconstructing Galapagos Paleohydrology

    … n-alkanes, n-alkanols, and taraxerol, along with calibration data sets for mangrove- and algal-lipids, from three different saline lakes in the southern part of Isabela Island I quantitatively reconstruct lake water hydrogen isotope and salinity changes. The data imply that the region experienced …

    washington Repository record for Hydrogen Isotopes from Lipid Biomarkers: Purification, Field Calibration, and Application to Reconstructing Galapagos Paleohydrology (opens in a new tab)

  4. Operational (in-field) calibration methodology of video quality evaluation of MPEG2 compressed data for broadcast.

    … is used to generalize an application for In-Field operational calibration standard of subjective/objective digital video evaluation for TV network and broadcast stations. A practical experiment for validating the correlation between the subjective evaluations of some MPEG2 coded streams vs. …

    ottawa-retro Repository record for Operational (in-field) calibration methodology of video quality evaluation of MPEG2 compressed data for broadcast. (opens in a new tab)

  5. Modeling Study of Proposed Field Calibration Source Using K-40 Source and High-Z Targets for Sodium Iodide Detector

    … high-Z metals between 60 and 80 keV. A gamma ray calibration source is thus proposed that uses potassium chloride salt and a high-Z metal to create a two-point calibration for a sodium iodide field gamma spectroscopy instrument. The calibration source was designed in collaboration with Sandia …

    tamu Repository record for Modeling Study of Proposed Field Calibration Source Using K-40 Source and High-Z Targets for Sodium Iodide Detector (opens in a new tab)

  6. FIELD CALIBRATION OF LOW COST AIR QUALITY MONITORS IN TWO CHINESE CITIES WITH NON-LINEAR REGRESSION AND ARTIFICIAL NEURAL NETWORK TECHNIQUES

    … conditions (RH<95%). Among all three calibration methods, the ANN approach shows the highest correlation between the estimated and BAM-1020 measured hourly PM2.5 (R^2=0.76). PM2.5 estimated from the power-law equation demonstrates a slightly better agreement (R^2=0.70) with BAM-1020 …

    tamu Repository record for FIELD CALIBRATION OF LOW COST AIR QUALITY MONITORS IN TWO CHINESE CITIES WITH NON-LINEAR REGRESSION AND ARTIFICIAL NEURAL NETWORK TECHNIQUES (opens in a new tab)

  7. Status of sound field audiometry among audiologists in the United States.

    Results of a national survey on sound field usage and sound field calibration are presented. The purposes of this study are: (1) to describe and analyze sound field stimuli, sound field test conditions, and sound field calibration procedures currently employed by audiologists nationwide, and (2) to …

    arizona-thes Repository record for Status of sound field audiometry among audiologists in the United States. (opens in a new tab)

  8. Calibrating digital photogrammetric airborne imaging systems using a test field

    … sensors and rigorous processing. The calibration processes of the digital photogrammetric airborne imaging systems are under development. Central challenges in the development of the calibration are the extensive variation in digital systems, the need for radiometric calibration, and …

    aalto Repository record for Calibrating digital photogrammetric airborne imaging systems using a test field (opens in a new tab)

  9. Robust remote measurement calibration

    The objective of Remote Measurements Calibration (RMC) method is to minimize systematic errors through an appropriate scaling procedure. A new method for RMC has been developed. This method solves the problems of observability, multiplicity of solutions, and ambiguity of reference points associated …

    vt Repository record for Robust remote measurement calibration (opens in a new tab)

  10. Prediction of permanent deformations in asphalt concrete using the mechanistic-empirical pavement design guide

    … deformations using the M-E PDG software v0.910. Field calibration factors were assessed in order to match the model’s results with the HVS results. It was also to be investigated whether the indirect tensile test (IDT) on cored pavement specimens can replace the compressive uniaxial test on …

    lund Repository record for Prediction of permanent deformations in asphalt concrete using the mechanistic-empirical pavement design guide (opens in a new tab) Download PDF for Prediction of permanent deformations in asphalt concrete using the mechanistic-empirical pavement design guide (opens in a new tab)

  11. Serendipitous asteriod survey using SuperWASP

    … = 7 − 15. Each camera covers a 7.8 x 7.8 degree field of view. This large field of view produces both advantages and disadvantages for minor planet observations. Slow moving asteroids stay within a single SuperWASP field for several weeks, and may be seen in many fields, providing the opportunity …

    the-open-u Download PDF for Serendipitous asteriod survey using SuperWASP (opens in a new tab)

  12. Microwatt integrated radio transceiver circuits for aggressively duty-cycled wireless networks

    … a temperature compensation method and an in-field calibration procedure for microwatt NB-IoT modems. Low-power wide-area networks, such as NB-IoT, have a range in the order of several kilometers. The impulse radio TFE is fabricated in a 65-nm CMOS process. The TFE is measured to produce …

    aalto Repository record for Microwatt integrated radio transceiver circuits for aggressively duty-cycled wireless networks (opens in a new tab)

  13. Using Radio-Frequency Identification Technology To Measure Asphalt Cooling

    … of the SAW RFID sensors are demonstrated in the field. The measured asphalt cooling curves (temperature versus time) are compared with predictions from previously developed theoretical models for mat cooling. The prediction accuracy of these models is improved via a field calibration procedure …

    maryland Repository record for Using Radio-Frequency Identification Technology To Measure Asphalt Cooling (opens in a new tab)

  14. Remote measurement calibration in power system

    … of measurements is in thousands. Routinely field technicians must calibrate transducers and/or determine other sources of metering errors. Due to the large number of measurements and the time required to check each individual measurement, field calibration procedures are impractical, …

    njit Repository record for Remote measurement calibration in power system (opens in a new tab)

  15. Predicting soil strength with remote sensing data

    … sponsored a multi-sensor remote sensing and field calibration and field validation campaign (CNMI'10). The team traveled to the islands of Pagan, Tinian, and Guam located in the Marianas archipelago. Airborne hyperspectral imagery along with ground truth data was collected from shallow water …

    nps Repository record for Predicting soil strength with remote sensing data (opens in a new tab)

  16. Evaluation of a low-cost sensor used to examine CO2 urban gradients

    … where concentrations are higher. We tested field calibration methods for low-cost CO2 sensors in a stationary ambient multipollutant monitoring network in Baltimore, MD using collocated reference CO2 data. We found that random forest machine learning models markedly outperformed multiple …

    jhu Repository record for Evaluation of a low-cost sensor used to examine CO2 urban gradients (opens in a new tab)

  17. Soil property estimation using visible and near-infrared reflectance

    … carbon and nitrogen, respectively. Results with field-moist soil were nearly as accurate, showing that this may be a viable, and more efficient, option. The mobile two-band sensor was evaluated in two central Missouri production fields. It showed good accuracy (R2 = 0.75) for estimating soil …

    missouri Repository record for Soil property estimation using visible and near-infrared reflectance (opens in a new tab)

  18. Robust Statistical Methods for Measurement Calibration in Large Electric Power Systems

    The Objective of the Remote Measurements Calibration (RMC) method is to minimize systematic errors through an appropriate scaling procedure. A new method for RMC has been developed. This method solves the problems of observability, multiplicity of solutions, and ambiguity of reference points …

    vt Repository record for Robust Statistical Methods for Measurement Calibration in Large Electric Power Systems (opens in a new tab)

Page 1 of 3