Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 36 for “"Filter Free"”.
-
Respiratory-gated liver stereotactic radiotherapy in flattening filter free photon mode
… using a higher dose rate, provided by flattening filter free (FFF) photon mode. To validate that increasing dose rate through removal of the flattening filter does not decrease cell kill, radiobiological experiments were carried out with three cell lines. Both the clonogenic survival assay and …
-
Improved Target Coverage of Spinal Metastases Through The Use of Flattening Filter Free Beams
… and tumor recurrence at follow-up. Flattening Filter Free (FFF) photon beams have been shown to have lower out-of-field dose and sharper dose gradients when compared with conventionally flattened (FF) photon beams of similar energy; this sharp dose fall-off could potentially prove beneficial in …
-
Flattening Filter Free photon beams for treatment of early-stage lung cancer: an investigation of peripheral dose
… for 10X, 6X, and 10X-FFF beams. Flattening Filter Free (FFF) radiotherapy photon beams exhibit high dose rates as compared to standard flattened photon beams. The high dose rates available with FFF beams make them ideal for high dose treatments, such as Volumetric Modulated Arc Therapy …
-
Developing a QA procedure for gated VMAT SABR treatments using 10 MV beam in flattening-filter free mode
… Therapy (VMAT) using a 10 MV beam in Flattening Filter Free (FFF) mode. This method takes advantage of the high dose gradient region of SABR treatments to detect any inaccuracies in the performance of the Varian Real-time Position Manage- ment (RPM) gating system. This study involves the design …
-
Monte Carlo modelling of peripheral dose and risk of secondary malignancy in flattening-filter-free and 10 MV photon beams for paediatric radiotherapy
… treatment modes: 6MV flattened, 6MV flattening-filter-free (FFF) and 10MV FFF. To establish the clinical significance of the dose difference between the three modes, the risk of SMN as calculated by four different risk models was assessed for whole lung irradiation (WLI). The mixed Monte Carlo …
-
Evaluation of The Effectiveness of Anisotropic Analytical Algorithm In Flattened and Flattening-Filter-Free Beams For High Energy Lung Dose Delivery Using The Radiological Physics Center Lung Phantom
… lung phantom using both flattened and flattening-filter-free high energy beams. Radiation treatment plans were developed following the Radiation Therapy Oncology Group and theRadiologicalPhysicsCenterguidelines for lung treatment using Stereotactic Radiation Body Therapy. The tumor was covered …
-
Absorbed dose in the build-up region in modern megavoltage photon radiotherapy
… 6.2x20 cm². Secondly, we focussed on flattening filter-free linear accelerators, which currently face swift implementation into clinical practice because of their increased dose rate and reduction in head scatter compared to conventional designs. Our study demonstrated that build-up doses in …
-
Konstrukce audio výkonového zesilovače spínané koncepce
… simulace částí zesilovače v programu PSpice a Filter Free. Ve třetí části práce je rozebrán návrh napájecí jednotky. Poslední část práce je zaměřena na zpracované výsledky měření na prototypu zařízení.
-
Dosimetric effects of removing the flattening filter in radiotherapy treatment units
… dosimetric effects of removing the flattening filter from conventional C-arm medical linear accelerators. In conventional linear accelerators used for radiotherapy, a flattening filter is positioned in the beam line to provide a uniform lateral dose profile at a specified depth in water. …
-
Data compressive paradigm for spectral sensing and classification using electrically tunable detectors
… IR detector without employing any spectral filters; (2) further demonstration of the spectral-classification capability of tunable DWELL IR focal-plane array (FPA), again without using any spectral filters; and (3) development of a generalized filter-free data-compressive spectral sensing …
-
Implementation of TG-351 Reference Dosimetry for a 6 MV Photon Beam in an MR-Guided Radiotherapy System
… reference dosimetry for a 6 MV flattening filter-free (FFF) photon beam from a Viewray MRIdian MR-Linac radiation therapy system. Beam quality determination, magnetic field correction factors, and radial profile corrections for FFF beams are included in the calculation for absorbed dose to …
-
Integration of a Visible-Telecom Photon Pair Source with Silicon Photonics for Quantum Communication
… such frequency conversion systems like spectral filtering losses, out-coupling losses and feasibility of scalable fabrication are addressed by demonstrating the successful integration of the PPKTP crystal with a Silicon Photonics Integrated Circuit (Si-PIC). Higher pair detection rates than …
-
Unflattened Radiotherapy beams; characterisation, optimisation and application
… of this thesis was to investigate flattening filter free (FFF) beams produced by medical linear accelerators for radiotherapy applications, from their initial setup through to their clinical implementation. This was split into four sections that comprise the main experimental chapters of this …
-
Schrödinger bridges for Bayesian filtering - Enabling cost-effective filtering in nonlinear state space models
While particle filters are able to approximate the filtering distribution in nonlinear and non-Gaussian scenarios, they suffer from an inherent flaw known as weight degeneracy. This leads to rough state estimates and wasted computational resources. This thesis seeks to mitigate weight degeneracy in …
-
A Non-filtering Gear Fault Detection Method
… energy operator. The proposed methods are filter free, simple and can handle a certain level of noise and interference. With the exception of low rotational frequencies of the gears, it can be concluded from simulated and experimentally-obtained signals that the CEEO method can handle noise …
-
Operation, characterisation & physical modelling of unflattened medical linear accelerator beams and their application to radiotherapy treatment planning
The flattening filter is a conical shaped piece of metal sitting within the treatment head of a linear accelerator, used to produce a flat, uniform beam of X-rays from the forward-peaked distribution exiting the target. Despite their routine use since the introduction of the linac in the 1950’s, …
-
Optimising treatment outcomes using Stereotactic Body Radiotherapy (SBRT) for prostate cancer
… SABR planning using flattened and flattening filter free (FFF) beams. A systematic review examined RISPC risk following prostate radiotherapy. A final study estimated RISPC risks following prostate SABR in comparison to other contemporary radiation techniques. Results: Prostate SABR was …
-
Developing quality assurance procedures for gated volumetric modulated arc therapy in stereotactic ablative radiation therapy
… linear accelerator using a 10FFF (flattening filter free) beam and Varian’s real-time position management (RPM) system for respiratory gating. Two kinds of breathing patterns were used: free breathing (FB) and an interrupted (~5 s pause) end of exhale coached breathing (CB) pattern. Ion …
Page 1 of 2