Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 48 for “"Filtered backprojection"”.

  1. A hardware reconstruction system for real-time magnetic resonance imaging via 2D FFT or filtered backprojection

    … images via either the 2D FFT algorithm or the filtered backprojection algorithm. The 2D FFT hardware reconstructs 256 x 256 images from complex-valued data (on a rectilinear grid) at a rate of 30 frames/sec while the filtered backprojection hardware is capable of reconstructing 64 x 64 images …

    arizona-thes Repository record for A hardware reconstruction system for real-time magnetic resonance imaging via 2D FFT or filtered backprojection (opens in a new tab)

  2. Iterative transmission image reconstruction for the DPET positron emission tomograph

    … using single slice rebinning followed by filtered backprojection. Single slice rebinning attributes the attenuation associated with an oblique line integral to the direct midplane intersected thereby. This leads to position-dependent axial blurring, especially for large diameter animals, …

    utk-theses Repository record for Iterative transmission image reconstruction for the DPET positron emission tomograph (opens in a new tab)

  3. Efficient Cone Beam Reconstruction For The Distorted Circle And Line Trajectory

    We propose an exact filtered backprojection algorithm for inversion of the cone beam data in the case when the trajectory is composed of a distorted circle and a line segment. The length of the scan is determined by the region of interest , and it is independent of the size of the object. With few …

    ucf Repository record for Efficient Cone Beam Reconstruction For The Distorted Circle And Line Trajectory (opens in a new tab)

  4. Software tools for 3-D PET imaging : design and development

    … implemented include Fourier rebinning (FORE) and filtered backprojection (FBP). Filtered backprojection is implemented as a 2D reconstruction method and FORE as a 3D reconstruction application which rebins 3D data into 2D data sets and then uses the filtered back projection method to reconstruct …

    ut-knoxville Repository record for Software tools for 3-D PET imaging : design and development (opens in a new tab)

  5. Τα μαθηματικά της Υπολογιστικής Τομογραφίας

    … Θα ξεκινήσουμε με τον ευρέως γνωστό αλγόριθμο filtered backprojection και θα μελετήσουμε την πιθανή λύση. Στη δεύτερη ενότητα θα δώσουμε μία ανάλυση σφάλματος του αλγορίθμου Fourier ο οποίος οδηγεί σε ένα βελτιωμένο αλγόριθμο, συγκρίσιμο σε ακρίβεια με τον filtered backprojection.

    athens Repository record for Τα μαθηματικά της Υπολογιστικής Τομογραφίας (opens in a new tab)

  6. Magnetic resonance microscopy

    An n-dimensional (nD) filtered backprojection image reconstruction algorithm has been developed and used in the reconstruction of 4D spectral-spatial magnetic resonance imaging (MRI) data. The algorithm uses n-1 successive stages of 2D filtered backprojection to reconstruct an nD image. This …

    uiuc Repository record for Magnetic resonance microscopy (opens in a new tab)

  7. Efficient Inversion Of The Cone Beam Transform For A General Class Of Curves

    … is found where reconstruction is possible with a filtered backprojection type algorithm. Results of numerical experiments demonstrate very good image quality. The algorithm developed is useful for image reconstruction in computerized tomography.

    ucf Repository record for Efficient Inversion Of The Cone Beam Transform For A General Class Of Curves (opens in a new tab)

  8. Medical image tomography: A statistically tailored neural network approach

    … reconstructions are typically produced using a filtered backprojection algorithm. Filtered backprojection methods have limitations that create a high percentage of statistical uncertainty in the reconstructed images. Many techniques have been developed which produce better reconstructions, but …

    iastate Repository record for Medical image tomography: A statistically tailored neural network approach (opens in a new tab)

  9. Applications of Multi-Pinhole Gamma Camera Collimation to Tomography and Image Enhancement

    … were written to reconstruct the images by simple backprojection and by filtered backprojection.

    uiuc Repository record for Applications of Multi-Pinhole Gamma Camera Collimation to Tomography and Image Enhancement (opens in a new tab)

  10. Fast Algorithms for Tomography

    … size, with an accuracy comparable to the filtered backprojection (FBP) algorithm. Next, a fast reprojection algorithm is presented, which uses a hierarchical decomposition of the Radon transform. In conjunction with the fast backprojection algorithm, this novel algorithm enables the use of …

    uiuc Repository record for Fast Algorithms for Tomography (opens in a new tab)

  11. A GPU Implementation of Distance-Driven Computed Tomography

    … before the image may be viewed. In comparison to filtered backprojection methods of reconstruction, iterative reconstruction algorithms have been shown to increase overall image quality by incorporating a more complete model of the underlying physics. Unfortunately, iterative algorithms are …

    ut-knoxville Repository record for A GPU Implementation of Distance-Driven Computed Tomography (opens in a new tab)

  12. Itera- tive Reconstruction Framework for High-Resolution X-ray CT Data

    … Currently, clinical CT scanners typically use a Filtered Backprojection (FBP) based method for image reconstruction. This algorithm is fast and generally produces acceptable results, but has several drawbacks. Firstly, it is based upon line integrals, which do not accurately describe the process …

    ut-knoxville Repository record for Itera- tive Reconstruction Framework for High-Resolution X-ray CT Data (opens in a new tab)

  13. CT fan beam reconstruction with a non-stationary axis-of-rotation

    … for every projection angle.</p><p>A convolution filtered backprojection algorithm has been derived for correcting images that were acquired with a non-stationary axis-of-rotation using the fan beam geometry with a collinear (flat) detector. Fan beam reconstruction algorithms which filter and …

    njit Repository record for CT fan beam reconstruction with a non-stationary axis-of-rotation (opens in a new tab)

  14. Doppler-only synthetic aperture radar

    … is necessary. This weighting is part of the Filtered Backprojection algorithm to determine the Inverse Radon transform of the sinogram. The backprojection portion is a simple redistribution of data back along the original projection line. Images were modeled by delta functions to test the …

    nps Repository record for Doppler-only synthetic aperture radar (opens in a new tab)

  15. Dissecção virtual e morfometria do girino Thoropa miliaris usando o algoritmo de recuperação de fase em imagens 3D obtidas com luz síncrotron

    … algorithm was used together with the filtered backprojection reconstruction algorithm. The use of these imaging and reconstruction techniques allowed access to information on the morphology and development of the internal structures of Thoropa miliaris, providing data regarding their …

    brazil-uerj Repository record for Dissecção virtual e morfometria do girino Thoropa miliaris usando o algoritmo de recuperação de fase em imagens 3D obtidas com luz síncrotron (opens in a new tab)

  16. Iterative Reconstruction of Cone-Beam Micro-CT Data

    … in most widespread use today are based on filtered backprojection (FBP) methods. These algorithms are rela- tively fast and work well on high quality data, but cannot easily handle data with missing projections or considerable amounts of noise. On the other hand, iterative reconstruction …

    utk-theses Repository record for Iterative Reconstruction of Cone-Beam Micro-CT Data (opens in a new tab)

  17. Evaluation of new iterative and rebinning reconstruction algorithms in fully three-dimensional positron emission tomography

    … Using phantom and patient data, the standard 3D filtered backprojection algorithm is used to assess the merits of faster alternatives to full 3D reconstructions: FORE + 2D FBP, FORE + OSEM and FORE + SAGE. The phantom figures of merit that are used to evaluate these new algorithms are: …

    ubc Repository record for Evaluation of new iterative and rebinning reconstruction algorithms in fully three-dimensional positron emission tomography (opens in a new tab) Download PDF for Evaluation of new iterative and rebinning reconstruction algorithms in fully three-dimensional positron emission tomography (opens in a new tab)

  18. Statistical methods for mapping kinetics together with associated uncertainties in long field of view dynamic PET studies

    … Numerical simulations using both direct Filtered Backprojection (FBP) and iterative Maximum Likelihood (ML) reconstructions are considered. Illustrative examples on conventional scanners and Long Axial Field-of-View (LAFOV) PET scanners are conducted. A short-duration dynamic scanning …

    cork Repository record for Statistical methods for mapping kinetics together with associated uncertainties in long field of view dynamic PET studies (opens in a new tab)

  19. Implementation of respiratory-correlated cone-beam CT on Varian linac systems

    … which uses conventional Feldkamp-Davis-Kress filtered backprojection. Four 4D scans of a periodically moving phantom have been taken, with different gantry speeds and mAs values. To evaluate the effect of these scan parameters on image quality, and demonstrate a potential application of 4D …

    ubc Repository record for Implementation of respiratory-correlated cone-beam CT on Varian linac systems (opens in a new tab) Download PDF for Implementation of respiratory-correlated cone-beam CT on Varian linac systems (opens in a new tab)

Page 1 of 3