  1. Robustness of flexible endplate connections under fire conditions.

    … and large buildings under exceptional loading conditions was heightened by the collapse of the twin towers at the World Trade. The performance of steel-framed structures subjected to fire loading is heavily reliant on the interaction between structural members such as columns, slabs and beams. …

    whiterose Download PDF for Robustness of flexible endplate connections under fire conditions. (opens in a new tab)

  2. Analysis of Fire Conditions in a Closed-End Tunnel

    Many studies have addressed fires in tunnels. For the most part, these previous studies have addressed fires that might occur during operation of the tunnel, when the tunnel has openings at both ends. During construction of a tunnel, the tunnel has only one opening as the tunnel is being bored. …

    maryland Repository record for Analysis of Fire Conditions in a Closed-End Tunnel (opens in a new tab)

  3. Behaviour of structures under fire conditions after earthquake events

    … of the behavior of steel structures under the Fireafter Earthquake loading. The problem is handled numerically. The study is focused on a four-storey library building. It is emphasized that the study takes into account the damage that is induced due to earthquake to both structural and …

    greece Repository record for Behaviour of structures under fire conditions after earthquake events (opens in a new tab)

  4. Performance characterization of high performance concretes under fire conditions

    … HPC, when used in buildings, have to satisfy the fire resistance requirements specified in building codes and standards. Although conventional concrete members have good fire resistance, same may not be true for HPC members due to faster degradation of strength with temperature and occurrence of …

    msu Repository record for Performance characterization of high performance concretes under fire conditions (opens in a new tab)

  5. Structural Integrity of Polymer Matrix Composites Exposed to Fire Conditions

    … (PMC's) perform well under many loading conditions and situations. Exposure of PMC's to fire is a concern due to their inherent material degradation at elevated temperatures. The elevated temperature response of PMC's to combined thermal and mechanical loads are especially of concern. PMC …

    vt Repository record for Structural Integrity of Polymer Matrix Composites Exposed to Fire Conditions (opens in a new tab)

  6. Behavior of FRP-strengthened reinforced concrete beams under fire conditions

    … strengthened member has to satisfy relevant fire resistance requirements specified in building codes and standards. Similar to other construction materials, FRP loses its strength and stiffness properties with temperature. However, the degradation in FRP properties is faster as compared to …

    msu Repository record for Behavior of FRP-strengthened reinforced concrete beams under fire conditions (opens in a new tab)

  7. Behavior of ultra-high performance concrete beams under fire conditions

    … construction, the provision of appropriate fire resistance is a key safety consideration. Since UHPC is a new construction material, there is limited information, as well as limited research on the fire performance of UHPC members. Preliminary research at the material and structural level …

    msu Repository record for Behavior of ultra-high performance concrete beams under fire conditions (opens in a new tab)

  8. Non-linear finite element analysis of steel frames in fire conditions.

    … use for behavioural studies on steel frames in fire conditions. The nonlinear structural analysis is based on a tangent stiffness formulation using large deformation theory. Deterioration in material strength and stiffness at increasing temperature is represented by a set of nonlinear …

    whiterose Download PDF for Non-linear finite element analysis of steel frames in fire conditions. (opens in a new tab)

  9. Flexural and shear response of precast prestressed concrete hollowcore slabs under fire conditions

    … forms of slab construction. Structural fire safety is one of the primary considerations in building design and hence, building codes specify fire resistance requirements for these hollowcore slabs. PC hollowcore slabs, under fire conditions, are susceptible to failure through shear …

    msu Repository record for Flexural and shear response of precast prestressed concrete hollowcore slabs under fire conditions (opens in a new tab)

  10. Evaluation of critical nuclear power plant electrical cable response to severe thermal fire conditions

    … of electrical cables exposed to severe thermal fire conditions are a safety concern for operating commercial nuclear power plants (NPPs). The Nuclear Regulatory Commission (NRC) has promoted the use of risk-informed and performance-based methods for fire protection which resulted in a need to …

    maryland Repository record for Evaluation of critical nuclear power plant electrical cable response to severe thermal fire conditions (opens in a new tab)

  11. Hollow steel section columns filled with self-compacting concrete under ordinary and fire conditions

    … comportement à température ordinaire et sous conditions d’incendie est analysé ainsi que les paramètres significatifs qui guident leur comportement. Les propriétés du béton auto-plaçant sont aussi examinées dans ce chapitre.Le chapitre 3 est consacré à la présentation du code de calcul SAFIR …

    liege Repository record for Hollow steel section columns filled with self-compacting concrete under ordinary and fire conditions (opens in a new tab)

  12. Development of a methodology for the estimation of the dynamic evolution of the flood - related hydrological behavior of periurban catchments under post - fire conditions

    … of time, following the occurrence of forest fires. The research focuses on flood risk assessment under post-fire conditions for Mediterranean periurban catchments. To this end, a methodological framework to theoretically estimate the dynamic evolution of hydrological parameters that affect …

    greece Repository record for Development of a methodology for the estimation of the dynamic evolution of the flood - related hydrological behavior of periurban catchments under post - fire conditions (opens in a new tab)

  13. The Analysis of Thermal and Fire Performance of Cementitious Building Components

    … behaviour of reinforced concrete members in fire conditions. The numerical analyses of temperature histories and mechanical behaviour of reinforced concrete structural members subjected to fire are the major components of this research. In this thesis a non-linear finite element procedure is …

    cent-lancashire Repository record for The Analysis of Thermal and Fire Performance of Cementitious Building Components (opens in a new tab) Download PDF for The Analysis of Thermal and Fire Performance of Cementitious Building Components (opens in a new tab)

  14. Aspects of the behaviour of single storey industrial buildings in fire

    … are a common form of construction; with fires within these buildings also being relatively common. The behavioural response of such buildings in real fire conditions Is investigated; more specifically the behaviour of the connections between the structural concrete and steel components of …

    vu-aus Download PDF for Aspects of the behaviour of single storey industrial buildings in fire (opens in a new tab)

  15. Advanced Computing and Sensing to Improve Mine Fire Characterization and Response

    After fire is discovered in an underground coal mine, a decision must be made to mitigate fire consequences. The decision should be made based on existing conditions, with the goal of increasing the probability of fire extinguishing without compromising the health and safety of the firefighting …

    vt Repository record for Advanced Computing and Sensing to Improve Mine Fire Characterization and Response (opens in a new tab)