Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 73 for “"Fire testing"”.

  1. A Methodology for Global Comparison of Fire Testing Standards in Transportation Applications

    … with a global perspective. In the area of fire safety, this requires understanding of, and compliance with, global regulatory requirements. This research develops a systematic approach that can be utilized to analyze and compare the complex fire safety regulatory requirements that are …

    waterloo Repository record for A Methodology for Global Comparison of Fire Testing Standards in Transportation Applications (opens in a new tab)

  2. Multi-Degree-of-Freedom Hybrid Fire Testing in a Non-Linear Environment

    Hybrid Fire Testing (HFT) is a performance-based approach for structures in fire based on substructuring method. A complete structure is divided in two substructures, one being in a fire test laboratory (physical substructure [PS]), and one being numerically simulated (numerical substructure [NS]). …

    liege Repository record for Multi-Degree-of-Freedom Hybrid Fire Testing in a Non-Linear Environment (opens in a new tab) Download PDF for Multi-Degree-of-Freedom Hybrid Fire Testing in a Non-Linear Environment (opens in a new tab)

  3. Development and implementation of a methodology for hybrid fire testing applied to concrete structures with elastic boundary conditions

    Fire tests remain a precious tool to comprehend the behavior of structures under accidental fire conditions. The common practice in fire testing is to isolate the tested element in a furnace in which the mechanical support conditions are maintained constant throughout the test. However, such tests …

    liege Repository record for Development and implementation of a methodology for hybrid fire testing applied to concrete structures with elastic boundary conditions (opens in a new tab) Download PDF for Development and implementation of a methodology for hybrid fire testing applied to concrete structures with elastic boundary conditions (opens in a new tab)

  4. Integrating Structural Fire Analysis with Hybrid Fire Testing: A Framework for Enhanced Stability, Software development and Full-Scale Evaluation.

    Abstract Understanding how structures behave in a fire is becoming increasingly important as engineers move toward performance-based design. Conventional fire-resistance tests evaluate isolated components under simplified and constant boundary conditions, and numerical models remain constrained by …

    carleton Repository record for Integrating Structural Fire Analysis with Hybrid Fire Testing: A Framework for Enhanced Stability, Software development and Full-Scale Evaluation. (opens in a new tab)

  5. Additively-Manufactured Hybrid Rocket Consumable Structure for CubeSat Propulsion

    … Gaseous oxygen was used as the oxidizer for hot-fire testing of prototype thrusters in ambient and vacuum conditions. Hot-fire testing in ambient and vacuum conditions on nine test articles with a combined total of 25 s burn time demonstrated performance repeatability. Vacuum specific impulse was …

    utahstate Repository record for Additively-Manufactured Hybrid Rocket Consumable Structure for CubeSat Propulsion (opens in a new tab)

  6. Intumescent formulations incorporating melamine phosphate

    Once familiar with the fire test rig constructed by M Kay, and modified to allow incorporation of both video and computer facilities, Melamine Phosphate production was scaled up from small to large laboratory scale, and then commercial scale production was considered. Samples produced at each stage …

    aston Download PDF for Intumescent formulations incorporating melamine phosphate (opens in a new tab)

  7. The Effects of Fire on Insulated Reinforced Concrete Members Strengthened With Fibre Reinforced Polymers

    … the structural performance of FRP’s during fire is preventing their widespread implementation in building applications. Because of the degradation of FRP material properties during heating, most current design codes completely neglect their structural contributions in fire design. The …

    queens Repository record for The Effects of Fire on Insulated Reinforced Concrete Members Strengthened With Fibre Reinforced Polymers (opens in a new tab)

  8. Multi-hazard analysis of steel structures subjected to fire following earthquake

    Fires following earthquake (FFE) have historically produced enormous post-earthquake damage and losses in terms of lives, buildings and economic costs, like the San Francisco earthquake (1906), the Kobe earthquake (1995), the Turkey earthquake (2011), the Tohoku earthquake (2011) and the …

    trento Repository record for Multi-hazard analysis of steel structures subjected to fire following earthquake (opens in a new tab)

  9. Glass Fibre Reinforced Polymer (GFRP) Internally Reinforced Concrete Slabs in Fire

    … durability. However, the performance of FRP in fire for applications in buildings demands more profound insights. The lack of adequate information on material characteristics at high temperatures for glass FRP (GFRP) bars creates uncertainty regarding the performance of GFRP reinforced concrete …

    queens Repository record for Glass Fibre Reinforced Polymer (GFRP) Internally Reinforced Concrete Slabs in Fire (opens in a new tab)

  10. Preliminary design of a 1 kN liquid propellant rocket engine testing platform

    … feed assembly can support both cold and hot fire testing campaigns and is equipped with numerous safety features including inert gas purge lines, emergency drain lines and emergency shut-down and de-pressurization procedures.

    cape-town Repository record for Preliminary design of a 1 kN liquid propellant rocket engine testing platform (opens in a new tab)

  11. Mast-antenna survivability : structural dynamic design analysis by component mode synthesis

    … methods also provide for the simulation of live fire testing. The methods allow the individual antenna and the mast to each be independently modeled, arbitrarily combined, and combined system dynamic response rapidly calculated to determine the structural survivability of a proposed mast/antenna …

    nps Repository record for Mast-antenna survivability : structural dynamic design analysis by component mode synthesis (opens in a new tab)

  12. Fire performance of concealed wood-steel-wood connections with perpendicular to grain reinforcement

    This study aimed to investigate the fire behaviour of concealed connections by considering the effects of parameters such as the number of bolts, bolt pattern and load ratios. The connections used for this study were fire-protected glulam beam-to-column reinforced concealed connections loaded …

    carleton Repository record for Fire performance of concealed wood-steel-wood connections with perpendicular to grain reinforcement (opens in a new tab)

  13. Human male and female biodynamic response to underwater explosion events.

    … data and video footage recorded during live fire testing were used to generate and validate ATB models for both a seated and a standing Hybrid III Anthropomorphic Test Device (ATD). Subsequently, these models were used to estimate the biodynamic response and injury potentials for both male …

    nps Repository record for Human male and female biodynamic response to underwater explosion events. (opens in a new tab)

  14. Melamine phosphate as a component of intumescent coatings

    … which have been tested on a small scale fire testing device, designed and calibrated within this project. The factors influencing performance in three fire test regimes are the percentage loading of melamine phosphate, its chemical constitution, crystal size and shape, thermal …

    aston Download PDF for Melamine phosphate as a component of intumescent coatings (opens in a new tab)

  15. Computerized Ballistic modeling of the Comanche tailfan shroud

    … operating in hostile environments. Ballistic testing is required on the Comanche prior to fielding. Computer based simulations are being employed in order to reduce requirements for expensive live-fire testing. This thesis uses a computer program called Dytran from MacNeal-Schwendler to …

    nps Repository record for Computerized Ballistic modeling of the Comanche tailfan shroud (opens in a new tab)

  16. Finite element modeling of the RAH-66 Comanche Helicopter Tailcone section using PATRAN and DYTRAN

    … operating in hostile environments. Ballistic testing is required on any new technology, including the Comanche, prior to fielding. This thesis uses computer programs called PATRAN and DYTRAN from MSC Software Corporation to build a model and simulate the effects of an explosive round …

    nps Repository record for Finite element modeling of the RAH-66 Comanche Helicopter Tailcone section using PATRAN and DYTRAN (opens in a new tab)

  17. Analysis of Semi-Rigid Connections Subject to Fire Loads in a Steel Framework

    … study is to develop an approach that considers fire as a load in the design of structures. Recent studies of the full-scale fire tests in Cardington, UK and the World Trade Centre collapse have shown that the behaviour of steel structures in fire when assembled into a frame differs from that …

    waterloo Repository record for Analysis of Semi-Rigid Connections Subject to Fire Loads in a Steel Framework (opens in a new tab)

  18. Manufacturing Greener Fire Retardants by Incorporating Bio-Based Materials into Intumescent Flame Retardant Polypropylene Composites

    … retardant composites: lignin or phytic acid. Fire testing on the lignin-containing composites showed only marginal improvements in fire retardancy. The phytic acid-containing composites exhibited very promising behavior, with substantially lower peak heat release rates and formation of stable …

    tamu Repository record for Manufacturing Greener Fire Retardants by Incorporating Bio-Based Materials into Intumescent Flame Retardant Polypropylene Composites (opens in a new tab)

  19. Fluid-interaction and cavitation effects on a surface ship model due to an underwater explosion

    … insight and savings in cost for future live fire testing and evaluation of the Flight IIA (DDG 79) design of the Arleigh Burke Destroyer.

    nps Repository record for Fluid-interaction and cavitation effects on a surface ship model due to an underwater explosion (opens in a new tab)

Page 1 of 4