  1. Developing Curve Fitting Procedure using X-ray Photoelectron Spectroscopy for N-Heterocyclic Carbenes

    … An X-ray photoelectron spectroscopy (XPS) peak fitting model was developed for 1,3-diisopropyl benzoimidazolium (iPrNHC) and some of its derivates. This informative and reproducible XPS peak-fitting model aimed to provide a curve-fitting routine for most bulk NHCs whilst also accounting for …

    uwo Repository record for Developing Curve Fitting Procedure using X-ray Photoelectron Spectroscopy for N-Heterocyclic Carbenes (opens in a new tab)

  2. The biophysical basis of accommodation in human peripheral nerve fibres

    … recordings, and to test the hypothesis that fitting techniques might reveal the underlying differences in membrane properties. It was first shown that the model could satisfactorily reproduce threshold electrotonus waveforms, and that a fitting procedure could identify changes in the …

    ucl Repository record for The biophysical basis of accommodation in human peripheral nerve fibres (opens in a new tab)

  3. Multiple target identification and direction finding using matched filtering techniques

    … filters and least mean squares polynomial curve fitting. The least mean squares polynomial curve fitting procedure is also used for direction finding for recoil/blast sources, using the unfiltered seismic signals.

    nps Repository record for Multiple target identification and direction finding using matched filtering techniques (opens in a new tab)

  4. Studies of the hydration of tricalcium silicate

    … from the rate parameters derived from the fitting procedure. However, it is shown that the amount of mechanistic information which can be obtained from such a fitting procedure is limited.</p> <p>Observation of the detailed chemical and morphological changes occurring during the hydration …

    oxford Repository record for Studies of the hydration of tricalcium silicate (opens in a new tab)

  5. Mixing and Doubly Cabibbo -Suppressed Decays of Neutral Charmed Mesons

    … wrong-sign decay. A detailed description of the fitting procedure, including extensive tests, is also included."

    uiuc Repository record for Mixing and Doubly Cabibbo -Suppressed Decays of Neutral Charmed Mesons (opens in a new tab)

  6. The low frequency structure of Cassiopeia

    … of Jennison and Latham, and Matheson. A model fitting procedure is described, based on a two component, four parameter model, from which it is concluded that the results are consistent with a symmetri­cal nebula of radius 135±3 arcsec. with a jet, of indeter­minate width, containing between 4% …

    kent Repository record for The low frequency structure of Cassiopeia (opens in a new tab)

  7. A simple embedded atom potential for palladium-hydride

    … Palladium (Pd) EAM potentials with large sets of fitting parameters, our Pd-H potential utilizes a reliable Pd EAM model with only six fitting parameters. The Pd-H model was fitted to experimental and DFT data, utilizing a constrained optimization procedure. Four octahedral crystal structures: …

    marshall Repository record for A simple embedded atom potential for palladium-hydride (opens in a new tab)

  8. Method development for the software-assisted analysis of triplet–doublet pairs

    … below. <br><br>Development of a practical fitting procedure for TDPs.<br>Spectral fitting provides an approach for the determination of the spin system magnetic parameters from a trEPR spectrum that requires no additional tools. To ensure plausible parameter sets, a practical fitting …

    freiburg-diss Repository record for Method development for the software-assisted analysis of triplet–doublet pairs (opens in a new tab)

  9. Method development for the software-assisted analysis of triplet-doublet pairs

    … below. <br><br>Development of a practical fitting procedure for TDPs.<br>Spectral fitting provides an approach for the determination of the spin system magnetic parameters from a trEPR spectrum that requires no additional tools. To ensure plausible parameter sets, a practical fitting …

    freiburg-diss Repository record for Method development for the software-assisted analysis of triplet-doublet pairs (opens in a new tab)

  10. Instrumental and perceptual evaluation of hearing devices: methods and applications

    … goal of providing optimum evaluation and fitting methods for hearing devices that are based on the needs and preferences of the individual user. As an efficient and comprehensive fitting procedure should include both, instrumental and perceptual assessments of each setting of the hearing …

    oldenburg Repository record for Instrumental and perceptual evaluation of hearing devices: methods and applications (opens in a new tab)

  11. Bone model to optimize implant selection in total hip arthroplasty

    … orthopaedic surgery in the world. This clinical procedure improves the quality of life for patients with chronic hip pain, by restoring their hip function with biocompatible prosthetic implants. However, there are still potential advances that can be made in selecting the optimal implant fixation …

    reykjavik Repository record for Bone model to optimize implant selection in total hip arthroplasty (opens in a new tab)

  12. Ferromagnetic Resonance Study of Square-Array Antidot Permalloy Thin Films

    … of 2-D standing spin waves. A simple theoretical fitting procedure is discussed and is shown have an average deviation of only 10% from the experimental data.

    ohiolink Repository record for Ferromagnetic Resonance Study of Square-Array Antidot Permalloy Thin Films (opens in a new tab)

  13. Characterizing etched grating profiles with the Alpha-particle Energy Loss method

    … a Monte Carlo simulation. By a least squares fitting procedure, the analytic simulation was used to extract grating parameters from the experimental spectra of two types of grating structures. A 1D grating of silicon bars on a free standing silicon dioxide support layer was fabricated and …

    ubc Repository record for Characterizing etched grating profiles with the Alpha-particle Energy Loss method (opens in a new tab)

  14. An analysis of middle ultraviolet dayglow spectra.

    … generated synthetic spectra. A least squares fitting procedure was developed for this purpose. Each data point was weighted using the standard deviation of the means. Synthetic spectra were generated for the following emissions: N2 Vegard-Kaplan; N2 Lyman-Birge-Hopf ield; NO y, 8, and e; 01 …

    nps Repository record for An analysis of middle ultraviolet dayglow spectra. (opens in a new tab)

  15. The dependence of protoplanetary disk properties on age and host star mass

    … along with a Markov Chain Monte Carlo (MCMC) fitting procedure to obtain these and other disk properties. This dissertation compiles the largest sample to date of consistently-modeled protoplanetary disks, probing how disk properties vary with host mass and age. The occurrence of planetary …

    bu Repository record for The dependence of protoplanetary disk properties on age and host star mass (opens in a new tab)

  16. Investigations on 208Pb fine-structure anomaly and nuclear charge radius via muonic atom calculations

    … methods, including our improvement, the fitting procedure, and the uncertainty analysis are presented in details. Finally, we discuss the results and examine potential sources of the remaining anomaly.

    heid-diss Repository record for Investigations on 208Pb fine-structure anomaly and nuclear charge radius via muonic atom calculations (opens in a new tab)

  17. electronic spectra and electronic energy levels of tetragonal chromium(III) complexes

    … parameters have been extracted from the fitting procedure. The parameters have been analyzed to understand the bonding of these complexes. We have also uncovered the low intensity absorption doublet bands and a high intensity charge transfer band of trans-[Cr(en)2(CN)2]ClO4 which occur …

    fau Repository record for electronic spectra and electronic energy levels of tetragonal chromium(III) complexes (opens in a new tab)

  18. B-Spline Based 3D Model Reconstruction and Finite Element Analysis of Human Knee Joint

    … FE simulation. A semi-automatic 3D point cloud fitting procedure in MATLAB based on B-Splines that accounts for contact geometries and CAD compatibility was developed in this thesis. The reconstructed model was then used for nonlinear stress-relaxation simulations under ramp compressions, where …

    calgary Repository record for B-Spline Based 3D Model Reconstruction and Finite Element Analysis of Human Knee Joint (opens in a new tab)

  19. Jet Energy Resolution Measurement of the ATLAS Detector Using Momentum Balance

    … of useable data. Second, a new statistical fitting procedure based on convolution is implemented to determine the detector response. These methods are demonstrated to accurately measure the jet energy resolution.

    carleton Repository record for Jet Energy Resolution Measurement of the ATLAS Detector Using Momentum Balance (opens in a new tab)

  20. Individual Differences in Stimulus Frequency Otoacoustic Emission Phase

    … the limitations of the frequency swept tone procedure and LS fit for estimating SFOAEs are not well understood. This investigation first focused on identifying limitations of such SFOAE and refining the LS fitting procedure. It was determined that including a suppressor was necessary for …

    cuny-grad Repository record for Individual Differences in Stimulus Frequency Otoacoustic Emission Phase (opens in a new tab)