Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 58 for “"Fixation devices"”.

  1. Improving Degradable Biomaterials for Orthopedic Fixation Devices

    Current degradable orthopedic fixation devices do not typically facilitate tissue integration during healing. Proposed here is a novel combination of processing methods to enhance the tissue integration capability of degradable thermoplastics used in temporary orthopedic fixation devices. The …

    temple Repository record for Improving Degradable Biomaterials for Orthopedic Fixation Devices (opens in a new tab)

  2. Melt processable biomaterials for degradable surgical fixation devices

    … however, many applications ranging from surgical fixation devices to drug delivery systems which require such combination properties. The work in this thesis is an attempt to increase the availability of such materials. Polyhydroxybutyrate-polyhydroxyvalerate copolymers are a new class of …

    aston Download PDF for Melt processable biomaterials for degradable surgical fixation devices (opens in a new tab)

  3. The stiffness response of several external fracture fixation devices

    Thesis (M.S.)--Michigan State University. Department of Metallurgy, Mechanics and Material Science, 1984

    msu Repository record for The stiffness response of several external fracture fixation devices (opens in a new tab)

  4. Improvement Of Biodegradable Biomaterials For Use In Orthopedic Fixation Devices

    Current orthopedic internal fixation devices, such as pins and screws, are typically made from metals and have a long list of complications associated with them. Most notably, complications such as infection or decreased wound healing arise from revisional surgeries needed to remove the used …

    temple Repository record for Improvement Of Biodegradable Biomaterials For Use In Orthopedic Fixation Devices (opens in a new tab)

  5. Development of testing systems to analyze strength of hormonally treated ligaments and stability of fixation devices

    … of the methodology to quantify the stability of fixation devices used to treat reverse obliquity intertrochanteric hip fractures. Determination of the optimal implant design to treat these types of fractures might help to decrease the high rate of unsuccessful recovery typically seen with these …

    ttu Repository record for Development of testing systems to analyze strength of hormonally treated ligaments and stability of fixation devices (opens in a new tab)

  6. Comparison of patient-specific fixation devices and -materials in one segmental mandibular reconstruction using a finite element analysis

    … of osseous non-union. Therefore, alternative fixation strategies such as the use of smaller plates (for example miniplates) and alternative materials (for example magnesium) are of interest. The present study aimed to evaluate the biomechanical conditions of a one segmental mandible …

    fu-berlin Repository record for Comparison of patient-specific fixation devices and -materials in one segmental mandibular reconstruction using a finite element analysis (opens in a new tab)

  7. Numerical and Experimental Assessment of MRI RF Coil Induced Heating for External Fixation Devices and Technique to Reduce the Thermal Effects

    … safety, especially with the presence of medical devices. This dissertation focuses on the MRI RF coil induced heating effects of external fixation devices and the technique to reduce such thermal impact. Different categories of external fixation devices, including modular external fixation …

    houston Repository record for Numerical and Experimental Assessment of MRI RF Coil Induced Heating for External Fixation Devices and Technique to Reduce the Thermal Effects (opens in a new tab)

  8. Biomechanical Evaluation of Two Methods of Humeral Shaft Fixation

    Biomechanical evaluations of fracture fixation devices attempt to determine implant performance by approximating the in vivo conditions. This performance is affected by many factors and relies on the complex bone-implant interface. Biomechanical tests can be designed in a variety of ways in order …

    clemson Repository record for Biomechanical Evaluation of Two Methods of Humeral Shaft Fixation (opens in a new tab)

  9. In vitro evaluation of veterinary and human suture anchors in metaphyseal bone of the canine tibia

    … orthopedic surgeons a mechanism for secure fixation of soft tissues to bone. A human system (TwinFix[superscript TM]) has been validated for clinical use by both in vitro and in vivo testing, and is considered to have acceptable strength to allow for appropriate healing in common …

    missouri Repository record for In vitro evaluation of veterinary and human suture anchors in metaphyseal bone of the canine tibia (opens in a new tab)

  10. Experimental evaluation of spinal fracture stabilization systems : comparison of Luque rectangles, the Kaneda device, and Harrington rods with sublaminar wires

    … Pak [3,16] to determine the ability of internal fixation devices to stabilize fractured spines. The system was designed to measure and calculate the relative 3 dimensional movement of vertebrae allowed by a fixation device when an instrumented spinal segment is subjected to physiologically …

    missouri Repository record for Experimental evaluation of spinal fracture stabilization systems : comparison of Luque rectangles, the Kaneda device, and Harrington rods with sublaminar wires (opens in a new tab)

  11. The Effect of Open Reduction on Fracture Healing

    … may be necessary to: 1) Obtain reduction or fixation when ordinary closed method have failed, 2) Prevent displacement of unstable fractures, 3) Promote union, and 4) Decrease morbidity (1). Many surgeons, however, hesitate to employ open methods of treatment because they believe that open …

    marquette Repository record for The Effect of Open Reduction on Fracture Healing (opens in a new tab)

  12. The Equilibrium Geometry Theory for Bone Fracture Healing

    … fracture healing can be used to design improved fixation devices and optimize clinical treatment. Existing models however, are limited because they fail to consider the changing fracture callus morphology and probabilistic behavior of biological systems. To resolve these issues, the Equilibrium …

    maryland Repository record for The Equilibrium Geometry Theory for Bone Fracture Healing (opens in a new tab)

  13. Effect of fiber-matrix coupling on the mechanical properties of a totally bioabsorbable composite

    … The use of these innovative materials in fixation devices could eliminate a second surgery to retrieve the implant, eliminate the corrosion problems with metallic devices and provide load transfer to the healing bone, minimizing stress protection atrophy.

    njit Repository record for Effect of fiber-matrix coupling on the mechanical properties of a totally bioabsorbable composite (opens in a new tab)

  14. Finite element analysis of orthopaedic plates and screws to reduce the effects of stress shielding

    … In the case of fracture healing with the use of fixation devices, a reduction in mechanical stimuli can lead to bone resorption. This phenomenon, known as stress shielding, is a common cause of failure in fracture fixation of long-bones. Using finite element models, this thesis studies the …

    ottawa-retro Repository record for Finite element analysis of orthopaedic plates and screws to reduce the effects of stress shielding (opens in a new tab)

  15. Development of an antimicrobial cement using human defensins-like antimicrobial peptides

    Bone cements are used in orthopaedics mainly as fixation devices in hip joints. One of the most important bone cements is Hydroxyapatite (HA) cement. It is widely used due to its advantages that include biocompatibility, bioactivity and low setting temperatures. HA cements can absorb bacteria …

    birmingham Download PDF for Development of an antimicrobial cement using human defensins-like antimicrobial peptides (opens in a new tab)

  16. Neoplastic Transformation of Cells by Orthopaedic Metals In Vitro

    … prostheses and the widespread use of fracture fixation devices have revolutionised the practice of orthopaedic and trauma surgery over the last thirty years. The metal alloys used for such implants are chosen both for their mechanical strength and high degree of biocompatibility. However, over …

    glasgow Download PDF for Neoplastic Transformation of Cells by Orthopaedic Metals In Vitro (opens in a new tab)

  17. Investigation of a HA/PDLGA/Carbon Foam Material System for Orthopedic Fixation Plates Based on Time-Dependent Properties

    … in bioresorbable materials for orthopedic fixation devices, the major challenge in utilizing these materials in load-bearing applications is creating materials sufficiently stiff and strong to sustain loads throughout healing while maintaining fracture stability. The primary aim of this …

    tamu Repository record for Investigation of a HA/PDLGA/Carbon Foam Material System for Orthopedic Fixation Plates Based on Time-Dependent Properties (opens in a new tab)

  18. Hughes external fixation device: studies of its biomechanical properties' effect on fracture healing and its clinical application

    External skeletal fixation devices first appeared in clinical practice in the 1850's. Their use has mainly been confined to Europe although North American surgeons developed an interest in the 1930's. In the last few years, however, there has been a reawakening of interest in external fixation in …

    edinburgh Repository record for Hughes external fixation device: studies of its biomechanical properties' effect on fracture healing and its clinical application (opens in a new tab)