Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 75 for “"Fixation methods"”

  1. Optimisation of locking plate fixation methods for periprosthetic fractures

    … an unstable prosthesis. Failure of locking plate fixation of fractures around the tip of a stable prosthesis (Vancouver type B1) have been reported clinically, suggesting that further investigation into their treatment is needed. This study developed a computational periprosthetic fracture …

    whiterose Repository record for Optimisation of locking plate fixation methods for periprosthetic fractures (opens in a new tab)

  2. Comparing Nasal Endotracheal Tube Fixation Methods in a Manikin Model

    Endotracheal tube fixation is a critical part of the intubation process intended to protect patients from the potentially catastrophic results of an unintentional mid-procedure extubation. Tube fixation techniques vary greatly between providers and institutions, with relatively little existing …

    ohiolink Repository record for Comparing Nasal Endotracheal Tube Fixation Methods in a Manikin Model (opens in a new tab)

  3. The Design, Fabrication, and Mechanical Characterization of Novel Rotator Cuff Fixation Methods

    … technique by increasing contact area between the fixation device and the tendon. This study aims to design prototype rivet and staple anchors to reduce the adverse effects of high tension by reducing local stress. A standardized mechanical test set up was developed using sawbones and rubber strips …

    ohiolink Repository record for The Design, Fabrication, and Mechanical Characterization of Novel Rotator Cuff Fixation Methods (opens in a new tab)

  4. Fixation methods for acute syndesmotic injury: a systematic review and meta-analysis

    … for unstable syndesmotic injuries. Various fixation methods exist for stabilisation of these injuries. Metal syndesmotic screws placed in a lateral to medial direction through the fibula into the tibia are considered the current gold standard. The number of screws, their location, the number …

    adelaide Repository record for Fixation methods for acute syndesmotic injury: a systematic review and meta-analysis (opens in a new tab)

  5. Optimisation Of Fixation Methods For Vancouver Type B2 And B3 Periprosthetic Femoral Fracture Treatment

    … be possible to counter-act the increased risk of fixation failure in osteoporotic patients by selecting a longer bridging distance.

    whiterose Repository record for Optimisation Of Fixation Methods For Vancouver Type B2 And B3 Periprosthetic Femoral Fracture Treatment (opens in a new tab)

  6. The Influence of Stem Design and Fixation Methods on the Lifetime of Total Hip Replacement

    Total hip replacement is one of the most common surgical procedures performed both in the UK and worldwide, with aseptic loosening cited as the primary reason for revision. Aseptic loosening is attributed to the wear debris generated by wear of the components. Recently, as great progress has been …

    huddersfield Repository record for The Influence of Stem Design and Fixation Methods on the Lifetime of Total Hip Replacement (opens in a new tab)

  7. In vitro three dimensional biomechanical comparison of two internal fixation methods in equine adult radii

    … fracture configurations conducive to internal fixation most often contain a spiral or oblique fracture of the distal diaphysis. The location and fracture configurations are biomechanically challenging because of the limited amount of bone available distally for screw purchase and the complex …

    missouri Repository record for In vitro three dimensional biomechanical comparison of two internal fixation methods in equine adult radii (opens in a new tab)

  8. Assessment of sample fixation methods in single-cell RNA-sequencing and single-cell analyses of nasopharyngeal carcinoma

    … we first evaluated the effect of methanol fixation in sample preservation and demonstrated the feasibility and data alternation carried by the scRNA-seq data that is generated from fixed samples. Our result showed that while fixed data can faithfully preserve biological information, the …

    hkust Repository record for Assessment of sample fixation methods in single-cell RNA-sequencing and single-cell analyses of nasopharyngeal carcinoma (opens in a new tab)

  9. The Effect of Wire Fixation Methods on the Measured Force Systems of a T-Loop Orthodontic Spring

    … system generated by T-loops have used rigid fixation for the spring ends. This is practical for laboratory studies, but it does not truly represent clinical situations in which orthodontic brackets are used to anchor spring ends. Results from laboratory studies have been applied to clinical …

    iupui Repository record for The Effect of Wire Fixation Methods on the Measured Force Systems of a T-Loop Orthodontic Spring (opens in a new tab)

  10. Biomechanical Testing of Salter-Harris Fractures Type I and II in the Distal Femur and Proximal Tibia

    … plate, exiting through the metaphyseal bone1. Fixation of these fracture types can be accomplished using a variety of methods including the use of Kirschner wires, cannulated screws, and a combination of both materials. Stability of fracture fixation is of utmost importance as persistent motion …

    clemson Repository record for Biomechanical Testing of Salter-Harris Fractures Type I and II in the Distal Femur and Proximal Tibia (opens in a new tab)

  11. Occipito-cervical fusion

    … of occipito-cervical fusion, including C2 fixation methods, the influence on clinical outcome, patient scoring systems and complications.

    cape-town Repository record for Occipito-cervical fusion (opens in a new tab)

  12. Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula

    … were divided into six groups of three different methods for fixation. Groups 1, 2 and 3 showed complete fractures in symphysis, characterized by a linear separation between the medial incisor, and groups 4, 5 and 6 showed complete fractures in parasymphysis with oblique design. Groups 1 and 4 …

    brazil-ufrn Repository record for Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula (opens in a new tab)

  13. A Numerical Study Of The Infix Percutaneous Anterior Pelvic Fixation: Analysis And Recommendations

    … to the pelvis is debilitating and often needs fixation intervention. In 58% of patients with this trauma, the injuries can lead to permanent disability, preventing the return to jobs. Of all unsuccessful fixation procedures, 42% are caused by failures of the method, sometimes due to …

    wayne-thes Repository record for A Numerical Study Of The Infix Percutaneous Anterior Pelvic Fixation: Analysis And Recommendations (opens in a new tab)

  14. Biomechanics of transapical mitral valve implantation

    … and understand the underlying biomechanics of fixation of transapical mitral valves within the native mitral annulus. Two different transapical mitral valve prosthesis designs were tested: One valve design has a portion of the leaflets atrialized such that it has a shorter stent height and the …

    colostate Repository record for Biomechanics of transapical mitral valve implantation (opens in a new tab)

  15. Development of functional biocomposite compression bone plates

    Bone plates are used as one of the fixation methods to restore damaged bones in orthopaedic surgery. Conventional bone plates are mainly made of stainless-steel. However, high stiff stainless-steel plates induce bone absorption and occasionally a plated bone suffers osteoporosis. Hence, it is …

    nus Repository record for Development of functional biocomposite compression bone plates (opens in a new tab)

  16. A Cadaveric Assessment of the Deltoid Ligament in Transsyndesmotic Ankle Injuries

    … of post-traumatic arthritis, despite appropriate methods of fixation. Current treatment involves syndesmotic screws or suture button fixation. Deltoid ligament repair has been considered an additional treatment option. The purpose of this study was to understand the role of the deltoid ligament in …

    uwo Repository record for A Cadaveric Assessment of the Deltoid Ligament in Transsyndesmotic Ankle Injuries (opens in a new tab)

  17. Nitrate Concentration in Streams as Related to Major Ion Chemistry

    … by living organisms. Industrial nitrogen fixation methods have greatly increased the production of reactive nitrogen and ultimately increased concentration of nitrate in natural waters. In natural streams, nitrate is recognized as a pollutant that can lead to some serious health issue for …

    umn Repository record for Nitrate Concentration in Streams as Related to Major Ion Chemistry (opens in a new tab)

  18. Assessing the Impact of Surgical Technique on Implant Migration, Tibiofemoral Contact Kinematics, and Functional Recovery Following Uncemented Total Knee Arthroplasty

    … provide a promising alternative to cemented fixation methods. Currently, a lack of consensus exists regarding which surgical technique is best suited to the uncemented TKA procedure. This thesis sought to examine the impact of surgical technique on tibial and femoral component migration. …

    uwo Repository record for Assessing the Impact of Surgical Technique on Implant Migration, Tibiofemoral Contact Kinematics, and Functional Recovery Following Uncemented Total Knee Arthroplasty (opens in a new tab)

  19. The development of rapid freezing techniques, and their application to an electron microscopical study of phloem structure

    … and conventional electron microscopical fixation methods. It was thought that rapid freezing, in association with freeze-substitution or freeze-fracturing, would stabilise the tissue and provide an image of the sieve element as little removed as possible from the in vivo condition. Thus, …

    auckland-ms Repository record for The development of rapid freezing techniques, and their application to an electron microscopical study of phloem structure (opens in a new tab)

  20. A new spectrometer to measure the molar Planck constant

    … had to be set up in vacuum. Drift-free fixation-methods and new designs for the optical elements, like corner-cube retro-reflectors, were developed. A new data acquisition system was elaborated, and also the mathematical theory to evaluate the acquired data. The new concepts for the …

    lmu-germany Repository record for A new spectrometer to measure the molar Planck constant (opens in a new tab)

Page 1 of 4