Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 72 for “"Flame Ionization Detection"”.
-
Thin layer chromatography - flame ionization detection analysis of in-situ petroleum biodegradation
… uses thin layer chromatography coupled with flame ionization detection (TLC-FID) to characterize the saturate and aromatic (hydrocarbon) fractions and the resin and asphaltene (non-hydrocarbon, polar) fractions. Other analysis techniques, such as HPLC-SARA analysis, are available for the full …
-
Characterization of Planar Titanium Platforms for Flame Ionization Detection in Microfluidic Gas Chromatography
Gas chromatography (GC) with a Flame Ionization Detector (FID) has been widely used for the analysis of volatile organic compounds in various fields. Instrument portability and miniaturization of the FID for micro GC (μGC) applications are of increasing interest. This thesis describes the design …
-
Measurement and Fractionation of Diesel Exhaust Hydrocarbons through Variable Temperature Controlled-Condensation and Flame Ionization Detection
… measuring hydrocarbons in engine exhaust is the flame ionization detector (FID). FID can measure total hydrocarbon concentrations but is limited in that it is not equally sensitive to all hydrocarbons present in exhaust. Instruments capable of measuring individual gas species such as gas …
-
Derivatization and Separation of Natural Estrogens (estrone, 17β-estradiol, and estriol) Using Gas Chromatography with Flame Ionization Detection (GC-FID)
… the levels of estrogens in the environment, a detection method was developed to identify and quantify three natural estrogens (estrone, 17β-estradiol and estriol) using gas chromatography with flame ionization detection (GC-FID). In addition, the efficacy of two derivatizing agents, …
-
Direct determination of 1-aminocyclopropane-1-carboxylic acid in plant tissues by using a gas chromatograph with flame-ionization detection
… acid by using a gas chromatograph with a flame–ionization detector. Ethylene production was measured in tissues from fruits, leaves, seeds, florets, and flower petals. The remaining tissue samples were ground to a fine powder in liquid nitrogen, and 1–aminocyclopropane–1–carboxylic acid …
-
Evaluation of Initial Flavor Fade in Fresh Roasted Peanuts using Gas Chromatography-Flame Ionization Detection, Gas Chromatography-Olfactometry, Sensory Analysis, and Chemosensory Techniques
Preventing flavor fade requires an understanding of the relationship between carbonyl amine and lipid oxidation reactions. The polyunsaturated fatty acid content of lipids in peanuts makes them more susceptible to lipid oxidation. The major by-products of the oxidation reaction are nonanal, …
-
A capillary column gas chromatography, resonance enhanced multiphoton ionization, time-of-flight mass spectrometry, laser-induced fluorescence, flame ionization detection system for the determination of polynuclear aromatic compounds in complex mixtures
… Chromatography, Resonance Enhanced Multiphoton Ionization, Time-Of-Flight Mass Spectrometry, Laser-induced Fluorescence, with parallel Flame Ionization Detection (CC/GC-REMPI-TOF/MS-LIF-FID). This system combines the selectivity and sensitivity of two complementary laser-based methods, REMPI and …
-
Polytetrahydrofuran-and Dendrimer-Based Novel Sol-Gel Coatings for Capillary Microextraction (CME) Providing Parts Per Trillion (ppt) and Parts Per Quadrillion (ppq) Level Detection Limits in Conjunction With Gas Chromatography and Flame Ionization Detection (FID)
… with gas chromatography (GC). Using a Flame ionization detector (FID), low parts per trillion (ppt) and parts per quadrillion (ppq) level detection limits were achieved in CME-GC for both polar and nonpolar analytes including polycyclic aromatic hydrocarbons (PAHs), aldehydes, ketones, …
-
Development and Validation of a Dynamic Vapor Sorption -Fast Gas Chromatography Method for Studying the Effects of Humidification and Temperature on Volatile Release From Amorphous Carbohydrate Glasses
… Sorption technology with fast gas chromatography-flame ionization detection for studying the effects of humidification and temperature on volatile release from amorphous glasses. Uncertainty analysis was performed on the results obtained from the validation experiments. The method was also used to …
-
Degradation of refractory organic pollutants in tar, water and soil matrices by ozone or hydrogen peroxide with ultraviolet light
… 27 specific PAH's was done by gas chromatograph (Flame Ionization Detection) for the reactants and products. The contaminated soil showed significantly lower levels of these PAH's after treatment.</p>
-
Preconcentration and direct flame ionization method for measurement of non-methane organic compounds in ambient air and statistical analysis of experimental data
… out by cryogenic preconcentration and a direct flame ionization detection method (PDFID). This system is sensitive and provides accurate measurement of ambient NMOC concentration even if the concentration is as low as 0.1 ppm carbon. The performance of the method was characterized using 19 pairs …
-
Catalytic Hydrodehalogenation and Hydrogenation of Halogenated Aromatic Organic Contaminants for Application to Soil Remediation
… by gas chromatography with electron capture detection (ECD) and flame-ionization detection (FID). Experimental data were consistent with a model in which dehalogenation and hydrogenation were considered sequential processes with first order reaction kinetics.
-
Determination of s-triazine herbicides in Manitoba soils
… determined by gas chromatography with alkali flame ionization detection. The recoveries of bound a-triazine residues from soils fortified at 1 ppm ranged from 81.6 to 94.5%. Two 15 minute ultrasonic extractions were comparable to 24 hours of Soxhlet extraction for atrazine. Sensitivity is …
-
Oil Dries: A New Absorbent Material For Collection Of Ignitable Liquids From Semi-Porous Material
… was obtained by gas chromatography coupled with flame ionization detection (GC-FID) and gas chromatography coupled with mass spectrometry (GC-MS). Chromatograms obtained from both oil dries for the various ignitable liquids used, resembled the chromatograms for the respective neat standards. This …
-
The Sensory and Analytical Analyses of Nonfat Milk Formulations: Stability to Light Oxidation and Pasteurization
… Solid phase microextraction-gas chromatography/flame ionization detection was used to analyze the concentrations of the volatile compounds (2-butanone, 2-pentanone, acetaldehyde, diacetyl, hexanal, methyl sulfide) found in the two components. Pasteurized unoxidized skimmed milk had measurable …
-
New Chemical Aerosol Characterization Methods- Examples Using Agricultural and Urban Airborne Particulate Matter
… desorption gas chromatography-mass spectrometry/flame ionization detection (GC-MS/FID) methodology was used to identify and quantify organic compounds in the aerosol particles. For the urban aerosols, I report the measurement of mass, and the chemical composition of size-resolved aerosols …
-
Isolation and Characterization of Polyurethane-Degrading Microorganisms
… culture, through Gas Chromatography (GC) with Flame Ionization Detection (FID).
-
Development of a headspace solid-phase microextraction (HS-SPME) procedure for the determination of short-chain fatty acids (SCFAs) in activated sludge by GC-FID
… the development of a feasible method for the detection of SCFAs in activated sludge using gas chromatography with flame ionization detection. Then, SCFA production was utilized as an indicator for the efficacy of wastewater treatment using samples from the Ann Arbor Wastewater Treatment …
-
Soil bacterium Bacillus subtilis (GB03) augments plant growth and volatile emissions in Eruca sativa (Arugula)
… subsequently analyzed by gas chromatography (GC) flame ionization detection (FID) and/or mass spectroscopy (MS). Total plant volatile emissions increased in Arugula by ca. 3 fold with GB03 exposure for 21 days compared with the water treated controls. The 6 peaks with the largest areas as observed …
-
Attraction of Culex pipiens pipiens L. (Diptera: Culicidae) to flower volatiles
… the extract was analyzed by gas chromatography-flame ionization detection (GC-FID) in an attempt to identify volatile compounds in the extract. The most abundant volatiles were identified as benzeneethanol (2-phenylethanol) and benzenemethanol (benzyl alcohol). Synthetic blends of these two …
Page 1 of 4