Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Flange joint"”.

  1. Deformation and Stresses Generated on The Bolted Flange Joint Assembly and The Grayloc Clamp Connector at Elevated Temperatures

    … leakage and structural integrity of the bolted flange joint assembly (BFJA) and Grayloc clamp connector (GCC), when each assembly was subjected to bolt preload, internal pressure and thermal loadings. The thermal loadings were divided into spatially-uniform and spatially-nonuniform temperatures. …

    carleton Repository record for Deformation and Stresses Generated on The Bolted Flange Joint Assembly and The Grayloc Clamp Connector at Elevated Temperatures (opens in a new tab)

  2. The Design and Manufacture of a Glass Fibre Reinforced Polymer (GFRP) Bolted Flange Joint for Oil and Gas Applications

    Metallic bolted flange and pipes both have been increasingly replaced by fibre reinforced polymer (FRP) materials in many applications which deal with extreme harsh environments such as oil, gas, marine, chemical etc. However, only a handful of research works have been conducted regarding the …

    plymouth Repository record for The Design and Manufacture of a Glass Fibre Reinforced Polymer (GFRP) Bolted Flange Joint for Oil and Gas Applications (opens in a new tab)

  3. Vibrations prediction and measurement of multi-stage bladed disks with non linear behavior due to friction contacts

    … the coupling of bladed disks by means of bolted flange joints. The efficiency of such systems in real working condition is strictly related to the dynamic properties of blades and disks constituting them. According to the current design practices, blades and disks are designed so that their …

    poli-torino Repository record for Vibrations prediction and measurement of multi-stage bladed disks with non linear behavior due to friction contacts (opens in a new tab)

  4. Monitoring and Analysis of Mn/DOT Precast Composite Slab Span System (PCSSS)

    … gages in the CIP just above the longitudinal flange joint at midspan and some of the longitudinal gages near the support. The cracking was associated with the restraint of environmental effects and shrinkage rather than due to vehicular loads. Transverse load distribution was evaluated with a …

    umn Repository record for Monitoring and Analysis of Mn/DOT Precast Composite Slab Span System (PCSSS) (opens in a new tab)

  5. Ai-Based Structural Health Monitoring of Oil & Gas Infrastructures and Lithium-Ion Batteries

    … oil and gas pipelines, defects including bolted flange looseness and pipeline erosion may cause structural failure. In energy storage systems, such as lithium-ion batteries, inaccurate state monitoring may reduce performance and compromise operational safety. Motivated by these challenges, this …

    houston Repository record for Ai-Based Structural Health Monitoring of Oil & Gas Infrastructures and Lithium-Ion Batteries (opens in a new tab) Embargoed until 2028-05-01

  6. Effect of temperature on the relaxation of polyvinyl chloride flanges

    … and building sites and household. Bolted flange joints are important components of piping systems. They are mainly used as dismountable connections between pressure equipment ensuring structural integrity and leakage tightness. Meanwhile, the flange is a recommended mean to connect …

    ets-quebec Download PDF for Effect of temperature on the relaxation of polyvinyl chloride flanges (opens in a new tab)

  7. Stress analysis of ASME B16.5 class 900 bolted flange joints subjected to bolt-up and pressure

    Bolted flange joint assemblies are used in many industries, mainly in oil, gas, and power generation facilities. The main role of a bolted flange manifests in connecting pipes, valves, and pressure equipment to ensure the pressurized substance flowing in the pipes. Although their usage may seem …

    ets-quebec Download PDF for Stress analysis of ASME B16.5 class 900 bolted flange joints subjected to bolt-up and pressure (opens in a new tab)

  8. Advanced Structural Health Monitoring for Connections with PZT Transducers and Image Processing Technique

    … including nut and bolt connections, welds, screw joints, pin connections, among others, are used in every industry. As connections are deployed into a variety of environments, a multitude of factors may cause the damage of the connections, including extreme temperatures, pervasive humidity or …

    houston Repository record for Advanced Structural Health Monitoring for Connections with PZT Transducers and Image Processing Technique (opens in a new tab)

  9. A calibrated dual-port acoustic Vector Network Analyser

    … developments; a repeatable acoustic waveguide flange/joint, a calibration method(s), calibration standards, and calibration verification. The hardware that has been developed is used as an accessory to an existing commercial VNA mainframe (Agilent-4395A) and a retrofitted test-set (HP87511A) …

    waikato-masters Repository record for A calibrated dual-port acoustic Vector Network Analyser (opens in a new tab) Download file for A calibrated dual-port acoustic Vector Network Analyser (opens in a new tab)

  10. Stress analysis of bolted flange joints with different shell connections

    … shells are joined permanently by welded joints or temporarily by bolted flange connections, also known as bolted flange joints, in pressure vessels and piping systems. A critical task in the design process is to determine the stress concentration level at the point where the shell meets …

    ets-quebec Download PDF for Stress analysis of bolted flange joints with different shell connections (opens in a new tab)

  11. Analysis of fiber reinforced plastic bolted flange joints

    … of pressure vessels and piping and FRP bolted flange joints have experienced a spectacular development to provide continuity for the flow of fluid through piping systems. In spite of the increased use of FRP composites in bolted flange joints and the good knowledge of these structures and their …

    ets-quebec Download PDF for Analysis of fiber reinforced plastic bolted flange joints (opens in a new tab)

  12. The effect of bolt spacing on the tightness behavior of bolted flange joints

    Bolted flange joints form a part of pressure vessels and piping components, and are used extensively in the chemical, petrochemical and nuclear power industries. They are simple structures and offer the possibility of disassembly, making them attractive for connecting pressurized equipment and …

    ets-quebec Download PDF for The effect of bolt spacing on the tightness behavior of bolted flange joints (opens in a new tab)

  13. Seismic safety evaluation of industrial piping systems and components under serviceability and ultimate limit state conditions.

    … and some components, e.g., elbows, bolted flange joints and Tee joints, do not have detailed design guidelines that take into account earthquake loading. Thus, a clear need for the development of improved seismic design rules for such systems is evident. In this respect, numerical and …

    trento Repository record for Seismic safety evaluation of industrial piping systems and components under serviceability and ultimate limit state conditions. (opens in a new tab)

  14. Možnosti vzdělávacích MOOC kurzů

    Diplomová práce si klade za cíl prozkoumat prostředí online kurzů MOOC a jejich využití pro účely normy ČSN EN 1591-4.V úvodní části práce jsou zmapovány české a zahraniční platformy poskytující kurzy MOOC. Celosvětově je využívá až dvě stě dvacet milionu uživatelů. Následuje vytvoření náplně …

    brno-tech Repository record for Možnosti vzdělávacích MOOC kurzů (opens in a new tab)

  15. Software pro výpočet přírub podle ČSN EN 13445

    Cílem této bakalářské práce je vytvořit jednoduchou přenosnou aplikaci pro pevnostní výpočet těsněných přírubových spojů dle normy ČSN EN 13445 – Netopené tlakové nádoby. Pro naprogramování byl zvolen programovací jazyk Python a program byl vytvořen v prostředí Eclipse. Práce obsahuje rešeršní …

    brno-tech Repository record for Software pro výpočet přírub podle ČSN EN 13445 (opens in a new tab)

  16. Hodnocení těsnosti těsněné trubkovnice

    Tato diplomová práce se zaměřuje na problematiku těsnosti těsněných trubkovnic výměníku tepla s U trubkami, který splňuje pevnostní požadavky norem ČSN EN 13 445-3 a ČSN EN 1591-1. Zabývá se silami působícími na těsnění při zohlednění vlivů působících na celý výměník tepla. Samostatná část je …

    brno-tech Repository record for Hodnocení těsnosti těsněné trubkovnice (opens in a new tab)

  17. Výpočtové posouzení přírubových spojů

    Diplomová práce se zabývá problematikou přírubových spojů. Vhodně navržená konstrukce a montáž přírubového spoje (PS) je nezbytná pro zajištění spolehlivosti potrubních systémů a strojních zařízení, kde jsou tyto spoje použity. Diplomová práce popisuje postupy jejich návrhu a posouzení z hlediska …

    brno-tech Repository record for Výpočtové posouzení přírubových spojů (opens in a new tab)

  18. Optické měření deformací přírubových spojů

    Tato diplomová práce se zabývá optickým měřením přírubových spojů při utahování a teplotním zatěžování. Jsou porovnány komerčně dostupné optické systémy se sestupnou invazivitou v průmyslovém prostředí. Různé stavy zatěžovaní jsou vyhodnoceny jak ve 3D (skenování, DIC), tak ve 2D (DIC). Měřením při …

    brno-tech Repository record for Optické měření deformací přírubových spojů (opens in a new tab)

  19. Posouzení přístupů pro výpočty přírubových šroubových spojů

    Tato bakalářská práce se zabývá problematikou návrhu a kontroly těsněných přírubových spojů. První část definuje pojem přírubový spoj a jeho namáhání. Mapuje a hodnotí možné varianty konstrukčního řešení. Zmíněna je také problematika předepjatých šroubových spojů, včetně silových poměrů ve spoji, …

    brno-tech Repository record for Posouzení přístupů pro výpočty přírubových šroubových spojů (opens in a new tab)

  20. Modifikace utěsnění víka primárního kolektoru PG VVER 440

    Cílem této diplomové práce je řešení problematiky, týkající se utěsnění víka primárního kolektoru parogenerátoru bloku jaderné elektrárny typu VVER 440. Tyto parogenerátory jsou těsněny v původním provedení niklovými kroužky. Modifikací stávajícího způsobu těsnění za nový druh těsnícího materiálu, …

    brno-tech Repository record for Modifikace utěsnění víka primárního kolektoru PG VVER 440 (opens in a new tab)

Page 1 of 2