Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 272 for “"Flashing"”.
-
Visibility thresholds for flashing lights
Thesis (Ph. D.)--Michigan State University. Department of Psychology, 1971
-
Performance measurements of a flashing flow nozzle
The performance of a flashing flow nozzle was quantified by efficiency and metastability measurements. Efficiency was calculated over a range of operating conditions, by using both inlet and exit conditions and the nozzle thrust. Metastability was quantified by a parameter that compared the …
-
The threshold detectability of slowly flashing lights
Thesis (M.A.)--Michigan State University. Dept. of Psychology, 1966
-
Effects of Flashing on Characteristics of Splashplate Nozzle Sprays
… sprays that work at high temperatures, called "flashing". Flashing can change spray pattern, breakup mechanism, droplets size, droplets velocity and mass distribution. In this thesis the objectives are first, to predict the conditions at which flashing can occur, and second, to predict the …
-
Warrants for Right-Turn Flashing Yellow Arrow Signal Phases
The right-turn flashing yellow arrow (FYA) signal phasing is a new signal practice in the United States. The Manual on Uniform Traffic Control Devices MUTCD (2009) allocates a signal phasing section for the right-turn FYA, which requires a four-section head FYA signal. It supports multiple phases' …
-
Laser-based measurements of two-phase flashing propane jets.
… study, by non-intrusive techniques, of two-phase flashing propane jets; propane (and LPG) being involved in the majority of major industrial two-phase accidental releases resulting in loss of life. Each jet release has been characterised by the measurement of its mass release rate, and temperature …
-
Measurement of the efficiency of a flashing flow nozzle
The efficiency of a flashing flow converging-diverging nozzle was measured. The primary motivation for measurement of nozzle efficiency in this work was to improve the performance of an ejector as a refrigerant expander; previous experimentation has suggested that motive nozzle efficiency is poor. …
-
Modelling and prediction of flashing flow in short tubes
The objective of this project was to develop a physically realistic method for predicting the flowrates in short tubes. A physically realistic model, though based on tests with one refrigerant, could be extrapolated to other refrigerants and to other refrigeration systems. Most of the existing …
-
Development of Guidelines for Flashing Yellow Arrows for Protected/Permissive Use
… phasing, which can then be implemented using flashing yellow arrows (FYA). This required determining how the risk for left-turn crashes varied as traffic-flow conditions varied during the course of a representative day. This was accomplished by developing statistical models, which expressed …
-
Improved closure relations for the two fluid-model in flashing flows
… equation, are studied and validated under flashing conditions with additional modifications proposed to improve the accuracy of the models. Three sets of experiments are performed in this work with a closed-loop test facility. Two-phase parameters are measured with four-sensor conductivity …
-
Flashing flow of refrigerant HFC-134a through a diabatic capillary tube
… refrigerant flow through a capillary tube is a flashing process, in which the state of the refrigerant changes from subcooled liquid to a vapor-liquid mixture. Metastable phenomena in the flow, i.e. a thermal nonequilibrium phenomena, may exist within a flashing process. Whereas a literature …
-
Exit choice in fire emergencies - Influencing choice of exit with flashing lights
… of exit. In the present research, the use of flashing lights to direct people to emergency exits is explored in a series of experiments in both buildings and road tunnels. Recommendations concerning how the system should be designed are developed based on the results. In addition, a framework …
-
The Effect of Flashing and Spraying Conditions on Black Liquor Droplet Formation
… rate. Black liquor sheet break-up mechanisms and flashing were found to affect droplet size. In test chambers, the median droplet size was found to be between 2 mm and 5 mm for low DSC (70%) black liquor, and between 4.5 mm and 15 mm for high DSC (75–78%) black liquor. The shapes of the droplets …
-
Quasi-one-dimensional numerical analysis of choked two-phase flashing flow through millitubes
… of these tubes is reliant upon critical flashing of the two-phase flow that controls the mass flow rate of the refrigeration system, resulting in a steep reduction in pressure and temperature. Due to the evaporating two-phase flow and the choked-flow condition, numerical analysis of flow …
-
Estudio teórico experimental del proceso de "flashing" de refrigerantes en válvulas de expansión
… and the development of a model based on the flashing process, with sufficient predictive ability to determine the mass flow rate circulating through the expansion valve according to the upstream fluid conditions and the opening valve. In order to determine accurately and precisely the minimum …
Page 1 of 14