Showing 1 to 18 of 18 for “"Flashover voltage"”.
-
Review of models which predict the flashover voltage of polluted insulators
Pollution of insulator surface could lead to a flashover of insulators. The flashover of insulators caused by pollution generally dominates at voltages above 500 KV. Mechanism of pollution flashover is very complex as it depends on numerous factors. Over the years researchers have presented various …
-
Estimation of positive polarity switching surge flashover voltage of compact transmission lines
… transmission line using ANSYS and estimates the flashover voltage and required clearances using an already established relationship between the flashover voltage and electric field characteristics. The first task in this project is to gather flashover data from publications and choose a procedure …
-
The effects of the insulator surface roughness on the surface flashover voltage of lucite, lexan, and celcon
… the insulator surface roughness on the surface flashover voltage of insulators. The surface flashover voltages for several common electrical insulators have been investigated for several different surface roughness groups. Lucite, Lexan, and Celcon samples were prepared with ten different …
-
Magnetic insulation of dielectric surfaces in vacuum using DC magnetic fields
… surface breakdown in vacuum using pulsed test voltages is investigated. Predictions from the "saturated surface avalanche" breakdown model and the experimental results show-magnetic insulation effects, i.e., an increase in flashover voltage, at magnetic field amplitudes as low as 0.1 T. The …
-
Pulsed magnetic field effects on dielectric surface flashover in vacuum
… of pulsed magnetic fields on dielectric surface flashover in vacuum is investigated under non-uniform field conditions. The magnetic field is applied parallel to the dielectric surface and perpendicular to the electric field, which is derived from a pulsed test voltage. Predictions from computer …
-
Επιφανειακή διηλεκτρική αντοχή μονωτικών υλικών σε ανομοιογενές ηλεκτρικό πεδίο υπό κρουστικές υψηλές τάσεις: επίδραση της υγρασίας
… in a non-uniform electric field under impulse voltages is investigated with emphasis given on the influence of humidity. Research on interactions between electrical discharges and insulating surfaces is of great importance, not only from the physical but also from the applications standpoints. …
-
Investigation of space charge profile on the flashover characteristics of fiberglass reinforced plastic (FRP) tools under HVDC conditions
In high voltage direct current (HVDC) electric power systems, live-line maintenance methods, using fibreglass reinforced plastic (FRP) tools, are being applied to enhance their reliability and avoid costly outages. The effects of direct current (DC) space charges are not well understood or …
-
Dielectric surface flashover in a simulated low earth orbit environment
… for the use of electrical energy at high voltages (for commercial, scientific or military applications) must utilize solid dielectrics as insulators. In general, surface flashover on insulators sets the limit on the applicable voltage of the system. For practical applications, scaling laws …
-
Gas-solid interfaces stressed with HV impulses : surface flashover behaviour and control
… solid spacers are used to insulate high voltage parts from extraneous metal parts, providing electrical insulation as well as mechanical support. The breakdown/flashover voltage, at which a discharge process initiates across the gas-solid interface, is important in the design process, as …
-
Flashover prevention on polystyrene high voltage insulators in a vacuum
… shielding techniques have been shown to increase flashover voltage, but the role of cathode vs. anode shielding is still not fully understood. Magnetic flashover inhibition has been considered but has not been experimentally confirmed for 45 degree coaxial insulators. Open circuit flashover …
-
Συμβολή στη μελέτη της ηλεκτρικής συμπεριφοράς ρυπασμένων μονωτήρων
… subject, experiments were carried out for the voltage and electric field distribution along and in the proximity of insulator strings used in the Hellenic transmission system for the suspension of high and ultra high voltage overhead transmission lines. The experimental results that have arisen …
-
Nonlinear Polymer Nanocomposite for Field Grading in Medium-Voltage Power Converters under High-Altitude and Humid Environments
… designed to enhance insulation within medium-voltage (MV) power modules and suppress flashover on printed-circuit boards (PCBs) at high altitudes. Electric field simulations of the triple-point (TP) region revealed strong E-field intensification at conductor-ceramic-silicone and …
-
Avaliação da suportabilidade dielétrica do isolamento em ar e coordenação de isolamento de linhas de transmissão
… traditionally used to determine the critical flashover voltage for switching surges have been developed over the years. However, it is known that this critical voltage depends on the shape of the electrodes and the electric field distribution along the gap, restricting their application with …
-
Surface charge characteristics of high voltage insulators and their flashover performance
… a common occurrence during service for all high voltage (HV) insulators as well as live-line tools during live-line maintenance work. This research focuses on studying the DC charging characteristics of different insulating materials as well as the flashover performance of such pre-charged …
-
Fast electrical and optical diagnostics for the early phase of dielectric surface flashover
… for the use of electrical energy at high voltages utilize solid dielectrics as electrical insulators, for which dielectric surface flashover is the primary factor limiting the magnitude of the applicable voltage. The voltage limitations imposed by dielectric surface flashover are …
-
A study of charge accumulation and spacer flashover in compressed gas insulation
… are identified as the most likely places for flashover to occur and they often determine the overall strength of a system. For energized system, surface charges have been observed on spacer surfaces and are considered to play an important role for anomalous flashover of a GIS or GITL system. …
-
Investigation of Lightning-Initiated Flashover Faults in Medium Voltage Overhead Lines - Modelling and Experimental Evaluation
Lightning can cause flashovers on Medium Voltage (MV) lines from both direct and nearby strikes. The work presented in this dissertation thoroughly investigates the characteristics of lightning-initiated flashover faults, expected overvoltage stress and the performance of different surge protection …
-
Měření elektrických parametrů plynů a plynných směsí přiloženým impulsním napětím